Author: Stefan Ritt 
Topic: Info 
Subject: Help parsing scdms_v1 data? 
The MIDAS event format is described here:

https://daq00.triumf.ca/MidasWiki/index.php/Event_Structure

All banks are aligned on a 8-byte boundary, so that one has effective 64-bit CPU access.

If you have sections of 168 or 192 bytes, this must be something else, like another bank (scaler event, slow control event, ...).

The easiest for you is to check how this events got created using the bk_create() function.