Entry  07 May 2009, Konstantin Olchanski, Info, midas misc timeout fixes 
    Reply  15 May 2009, Konstantin Olchanski, Info, midas misc timeout fixes 
    Reply  15 May 2009, Konstantin Olchanski, Info, midas misc timeout fixes 
Message ID: 577     Entry time: 15 May 2009     In reply to: 569
Author: Konstantin Olchanski 
Topic: Info 
Subject: midas misc timeout fixes 
> - cm_transition() timeouts now settable from ODB (/experiment/transition timeout, transition connect timeout). Rev 4479

transition connect timeout was actually only half of that specified because of an error in computing timeout arguments to the select() system 
call in recv_string() in system.c. This is now fixed.

rev 4488
K.O.