Back Midas Rome Roody Rootana
  Midas DAQ System  Not logged in ELOG logo
Entry  02 Jul 2009, Dawei Liu, Forum, Data taking hangs in the middle of run 
    Reply  03 Jul 2009, Pierre-Andre Amaudruz, Forum, Data taking hangs in the middle of run 
       Reply  06 Jul 2009, Dawei Liu, Forum, Data taking hangs in the middle of run 
          Reply  08 Jul 2009, Konstantin Olchanski, Forum, jorway73a.c, Data taking hangs in the middle of run 
             Reply  18 Jul 2009, Exaos Lee, Forum, jorway73a.c, Data taking hangs in the middle of run 
Message ID: 604     Entry time: 02 Jul 2009     Reply to this: 605
Author: Dawei Liu 
Topic: Forum 
Subject: Data taking hangs in the middle of run 
Hi,

We are using midas to read ADC. It sometimes hung in the middle of data taking.
We tried to disable analyzer and only run with frontend. The problem still
exists. We tried to use different crate, different CAMAC controller and
different ADC module. All these did not solve the problem. We use polled method
to read data. We have dataway display unit so we know that it hung always after
it executed CAMAC command F9, which is after finishing one data taking and clear
the ADC for the next data taking. The data rate is about 1 KHz. It is random for
how long it takes for the system to hang.

Any ideas ?

Thanks,

Dawei Liu
ELOG V3.1.4-2e1708b5