Message ID: 708     Entry time: 27 Jun 2010     In reply to: 707     Reply to this: 709
Author: Jimmy Ngai 
Topic: Forum 
Subject: Error connecting to back-end computer 
> Hi, there. I have not recently run mserver through inetd, and we usually do not do
> that at TRIUMF. We do this:
> 
> a) on the main computer: start mserver: "mserver -p 7070 -D" (note - use non-default
> port - can use different ports for different experiments)
> b) on remote computer: "odbedit -h main:7070" ("main" is the hostname of your main
> computer). Use same "-h" switch for all other programs, including the frontends.
> 
> This works well when all computers are on the same network, but if you have some
> midas clients running on private networks you may get into trouble when they try to
> connect to each other and fail because network routing is funny.

Hi K.O.,

Thanks for your reply. I have tried your way but I got the same error: 

[midas.c:8623:rpc_server_connect,ERROR] mserver subprocess could not be started 
(check path)

My front-end and back-end computers are on the same network connected by a router. I 
have allowed port 7070 in the firewall and done the port forwarding in the router (for 
connecting from outside the network). From the error message it seems that some 
processes can not be started automatically. Could it be related to some security 
settings such as the SELinux?

Best Regards,
Jimmy
ELOG V3.1.4-2e1708b5