Message ID: 710     Entry time: 28 Jun 2010     In reply to: 709     Reply to this: 711
Author: Jimmy Ngai 
Topic: Forum 
Subject: Error connecting to back-end computer 
> The way connections work under Midas is there is a callback scheme. The client starts 
> mserver on the back-end, then the back-end connects back to the front-end on three 
> different ports. These ports are assigned dynamically by the operating system and are 
> typically in the range 40000-60000. So you also have to allow the reverse connection on 
> your firewalls.

It works now after allowing ports 40000-60000 in the front-end computer. Thanks!