Back Midas Rome Roody Rootana
  Midas DAQ System  Not logged in ELOG logo
Entry  14 Dec 2012, Robert Casperson, Bug Report, MIDAS does not function correctly on F17 
    Reply  20 Dec 2012, Stefan Ritt, Bug Report, MIDAS does not function correctly on F17 
Message ID: 850     Entry time: 20 Dec 2012     In reply to: 845
Author: Stefan Ritt 
Topic: Bug Report 
Subject: MIDAS does not function correctly on F17 
If is not so easy to get out of zlib how many bytes have been written actually. I used an undocumented function, 
which breaks down on 64-bit systems.

I now rewrote the code in mlogger.cxx to use lseek() to "measure" actually the output file and set the values 
correctly. I tried on a few systems but am not 100% sure if it works everywhere. Can you please double check?

The fix is in SVN revision 5347.

/Stefan
ELOG V3.1.4-2e1708b5