Entry  12 Dec 2024, Stefan Ritt, Suggestion, New alarm sound flag to be tested 
We had the case in MEG that some alarms were actually just warnings, not very severe. This happens for example if we calibrate our detector 
once every other day and modify the hardware which actually triggers the alarm for about an hour or so.
    Reply  19 Dec 2024, Stefan Ritt, Suggestion, New alarm count added 
Another modification has been done to the alarm system. 

We have often cases where an alarm is triggered on some readout noise. Like an analog voltage just over the alarm threshold for a very short period of
Entry  17 Dec 2024, Lukas Gerritzen, Bug Report, [History plots] "Jump to current time" resets x range to 7d 
To reproduce:
- Open a history plot, click [-] a few times until the x axis shows more than 7 days.
- Scroll to the past (left)
    Reply  19 Dec 2024, Stefan Ritt, Bug Report, [History plots] "Jump to current time" resets x range to 7d 
I had put in a check which limits the range to 7d into the past if you press the "play" button, but now I'm not sure why this was needed. I removed it again
and 
things seem to be fine. Change is committed to develop.
Entry  13 Dec 2024, Marius Koeppel, Info, New Feature: Message Search filters.pdf
Dear all,

a new feature was implemented which allows to search the log messages in MIDAS. Attached one can find a more detailed explanation of how to use the feature.
Entry  18 Nov 2024, Lukas Gerritzen, Suggestion, Comma-separated indices in alarm conditions 
I have the following use case: I would like to check if two elements of an array exceed a certain threshold. 
However, they are not consecutive. Currently, I have to write two alarms, one checking Array[8] and one 
checking Array [10].
    Reply  10 Dec 2024, Stefan Ritt, Suggestion, Comma-separated indices in alarm conditions 
These kind of alarm conditions have been implemented and committed. The documentation at 

  https://daq00.triumf.ca/MidasWiki/index.php/Alarm_System
Entry  26 Nov 2024, Nick Hastings, Bug Report, TMFE::Sleep() errors 
Hello,

I've noticed that SC FEs that use the TMFE class with midas-2022-05-c often report errors when calling TMFE:Sleep().
    Reply  26 Nov 2024, Maia Henriksson-Ward, Bug Report, TMFE::Sleep() errors 
> Hello,

> I've noticed that SC FEs that use the TMFE class with midas-2022-05-c often report errors when calling TMFE:Sleep().
    Reply  27 Nov 2024, Konstantin Olchanski, Bug Report, TMFE::Sleep() errors 
> [tmfe.cxx:1033:TMFE::Sleep,ERROR] select() returned -1, errno 22 (Invalid argument).

The very original copy of this function had an error and was spewing out this error quite often,
    Reply  27 Nov 2024, Konstantin Olchanski, Bug Report, TMFE::Sleep() errors 

> I wonder also if now that midas requires stricter/newer c++ standards if there maybe
> some more straightforward method to sleep that is sufficiently robust and portable.
    Reply  27 Nov 2024, Konstantin Olchanski, Bug Report, TMFE::Sleep() errors 
>       status = select(1, &fdset, NULL, NULL, &timeout);
>
>       On error, -1 is returned, ... timeout becomes undefined.
       Reply  06 Dec 2024, Konstantin Olchanski, Bug Report, TMFE::Sleep() errors 
> >       status = select(1, &fdset, NULL, NULL, &timeout);
> >       On error, -1 is returned, ... timeout becomes undefined.
          Reply  06 Dec 2024, Konstantin Olchanski, Bug Report, TMFE::Sleep() errors 
> Commit [develop 06735d29] improve TMFE::Sleep()

Report of test_sleep on Ubuntu-22 (Intel E-2236) and MacOS 14.6.1 (M1 MAX Mac Studio).
Entry  06 Dec 2024, Stefan Ritt, Info, New slow control framework "mdev" PDCC.png
A new slow control mini-framework has been developed for MIDAS and been successfully tested in the Mu3e experiment. It 
might be suited for other experiments as well.
Entry  23 Oct 2024, Lukas Gerritzen, Bug Report, ODB key picker does not close when creating link / Edit-on-run string box too large Screenshot_2024-10-23_at_11.38.38.png
To reproduce:
In the interactive ODB, click the 🔗 icon to create a link. Next to the target,  click the "..." button to open 
the key picker browser. Then try to close it by either:
    Reply  02 Dec 2024, Stefan Ritt, Bug Report, ODB key picker does not close when creating link / Edit-on-run string box too large 
> Actual result:
> The key picker does not close.
       Reply  04 Dec 2024, Konstantin Olchanski, Bug Report, ODB key picker does not close when creating link / Edit-on-run string box too large 
> > Actual result:
> > The key picker does not close.
    Reply  02 Dec 2024, Stefan Ritt, Bug Report, ODB key picker does not close when creating link / Edit-on-run string box too large 
> Another more minor visual problem is the edit-on-start dialog. There seems to be no upper bound to the 
> size of the text box. In the attached screenshot, ShortString has a maximum length of 32 characters, 
> LongString has 255. Both are empty at the time of the screenshot. Maybe, the size should be limited to a 
       Reply  05 Dec 2024, Konstantin Olchanski, Bug Report, ODB key picker does not close when creating link / Edit-on-run string box too large 
> > Another more minor visual problem is the edit-on-start dialog. There seems to be no upper bound to the 
> > size of the text box. In the attached screenshot, ShortString has a maximum length of 32 characters, 
> > LongString has 255. Both are empty at the time of the screenshot. Maybe, the size should be limited to a 
Entry  15 Aug 2024, Scott Oser, Forum, "Safe" abort of sequencer scripts 
We often use the MIDAS sequencer to temporarily control detector settings, such as:

* <change some setting>
    Reply  19 Aug 2024, Stefan Ritt, Forum, "Safe" abort of sequencer scripts 
This request came more than once in the past. One thing I could implement is a "atexit" function similarly to the C funciton atexit().

Then we would have a function in the script which gets called whenever one does "stop immediately". This function can then restore
       Reply  22 Aug 2024, Scott Oser, Forum, "Safe" abort of sequencer scripts 
> This request came more than once in the past. One thing I could implement is a "atexit" function similarly to the C funciton atexit().

> Then we would have a function in the script which gets called whenever one does "stop immediately". This function can then restore
          Reply  02 Dec 2024, Stefan Ritt, Forum, "Safe" abort of sequencer scripts 
The atexit() function has been implemented in the current develop branch of midas, see

  https://daq00.triumf.ca/MidasWiki/index.php/Sequencer#ATEXIT_subroutine
    Reply  11 Sep 2024, Konstantin Olchanski, Forum, "Safe" abort of sequencer scripts 
> We often use the MIDAS sequencer to temporarily control detector settings, such as:

> * <change some setting>
Entry  30 Nov 2024, Pavel Murat, Bug Report, EQ_PERIODIC-only equipment ?  
Dear Midas experts, 

I'm running into something which looks like an initialization problem. 
    Reply  01 Dec 2024, Stefan Ritt, Bug Report, EQ_PERIODIC-only equipment ?  
There is no requirement that you pair an EQ_PERIODIC with an EQ_TRIGGER. Take for exmaple

  midas/examples/experiment/frontend.cxx
       Reply  01 Dec 2024, Pavel Murat, Bug Report, EQ_PERIODIC-only equipment ?  
> There is no requirement that you pair an EQ_PERIODIC with an EQ_TRIGGER. Take for exmaple

>   midas/examples/experiment/frontend.cxx
Entry  07 Oct 2024, Amy Roberts, Bug Report, Difficulty running MIDAS on Rocky 9.4 
We're trying to install the SuperCDMS version of MIDAS on a Rocky 9.4 Virtual 
Machine and are getting a persistent error when we run mserver.  As far as I 
know there are minimal changes between this and the MIDAS branch, but Ben Smith 
    Reply  07 Oct 2024, Ben Smith, Bug Report, Difficulty running MIDAS on Rocky 9.4 
> We're trying to install the SuperCDMS version of MIDAS on a Rocky 9.4 Virtual 
> Machine and are getting a persistent error when we run mserver.  As far as I 
> know there are minimal changes between this and the MIDAS branch, but Ben Smith 
       Reply  08 Oct 2024, Amy Roberts, Bug Report, Difficulty running MIDAS on Rocky 9.4 
> > We're trying to install the SuperCDMS version of MIDAS on a Rocky 9.4 Virtual 
> > Machine and are getting a persistent error when we run mserver.  As far as I 
> > know there are minimal changes between this and the MIDAS branch, but Ben Smith 
          Reply  08 Oct 2024, Konstantin Olchanski, Bug Report, Difficulty running MIDAS on Rocky 9.4 
I read these error messages. There is no ODB corruption. ODB semaphore is locked and all midas programs will fail, they will timeout trying to get the lock,
report the timeout, then it looks like a bug was introduced where instead of hard exit or abort() they attempt a clean shutdown which crashes from a recursive
call in db_lock_database(). Amy's 
             Reply  08 Oct 2024, Konstantin Olchanski, Bug Report, Difficulty running MIDAS on Rocky 9.4 
> I read these error messages. There is no ODB corruption. ODB semaphore is locked and all midas programs will fail...

Recovery from this is:
    Reply  07 Oct 2024, Konstantin Olchanski, Bug Report, Difficulty running MIDAS on Rocky 9.4 
> We're trying to install the SuperCDMS version of MIDAS on a Rocky 9.4 Virtual 
> Machine and are getting a persistent error when we run mserver.
>
       Reply  08 Oct 2024, Mark Grimes, Bug Report, Difficulty running MIDAS on Rocky 9.4 
We run Midas with no problems on Rocky 9.4, although not in a virtual machine.  We're very close to the head of `develop`.

I'm fairly sure I've seen an error like this before.  I didn't pay it much attention because it was transitory and I was doing something weird at the time
          Reply  08 Oct 2024, Konstantin Olchanski, Bug Report, Difficulty running MIDAS on Rocky 9.4 
> Basically I think Rocky 9.4 is a red herring.

This is what likely happened:
       Reply  08 Oct 2024, Amy Roberts, Bug Report, Difficulty running MIDAS on Rocky 9.4 
> > We're trying to install the SuperCDMS version of MIDAS on a Rocky 9.4 Virtual 
> > Machine and are getting a persistent error when we run mserver.
> >
          Reply  08 Oct 2024, Konstantin Olchanski, Bug Report, Difficulty running MIDAS on Rocky 9.4 
> I've uploaded the current core dump at: https://gitlab.com/det-lab/coredumps#.

I cannot read the core dump without the corresponding executable (and likely all it's shared libraries).
             Reply  10 Oct 2024, Amy Roberts, Bug Report, Difficulty running MIDAS on Rocky 9.4 
> > I've uploaded the current core dump at: https://gitlab.com/det-lab/coredumps#.

> I cannot read the core dump without the corresponding executable (and likely all it's shared libraries).
                Reply  13 Oct 2024, Konstantin Olchanski, Bug Report, Difficulty running MIDAS on Rocky 9.4 
Thank you for the stack trace, I fixed the buglet that cause midas programs to crash twice,
once on failure to lock ODB, then call exit() -> atexit() handlers -> cm_check_connect() -> crash on ODB lock 
failure is the cm_msg() codes.
                   Reply  16 Oct 2024, Amy Roberts, Bug Report, Difficulty running MIDAS on Rocky 9.4 
> Thank you for the stack trace, I fixed the buglet that cause midas programs to crash twice,
> once on failure to lock ODB, then call exit() -> atexit() handlers -> cm_check_connect() -> crash on ODB lock 
> failure is the cm_msg() codes.
                      Reply  18 Oct 2024, Konstantin Olchanski, Bug Report, Difficulty running MIDAS on Rocky 9.4 
> [aroberts@sdfcdmsdaq midas]$ odbedit
> [ODBEdit,ERROR] [odb.cxx:2043:db_open_database,ERROR] Removed ODB client 'ODBEdit', index 0 because process pid 
> 1615051 does not exists
                         Reply  18 Oct 2024, Konstantin Olchanski, Bug Report, Difficulty running MIDAS on Rocky 9.4 
> suddenly, an ODB semaphore timeout...

I am wondering if something bizarre is going on, like the system clock going backwards. I heard of things like that 
                            Reply  28 Oct 2024, Amy Roberts, Bug Report, Difficulty running MIDAS on Rocky 9.4 
> Now for each timeout it will print detailed syscall and timing information, if time goes backwards, it should catch it.

It appears that time is moving forward:
    Reply  06 Nov 2024, Amy Roberts, Bug Report, Difficulty running MIDAS on Rocky 9.4 
After following Konstantin's debugging suggestions, I thought I would try to replicate 
the issue on my own computer.  My hope was that I could provide instructions for 
replicating the bug so that the MIDAS team could try debugging things more easily.
       Reply  22 Nov 2024, Konstantin Olchanski, Bug Report, ODB lock timeout, Difficulty running MIDAS on Rocky 9.4 
> try to replicate the issue ...

I see ODB lock timeout (and abort() of everything) in the dsvslice test station. We have 
          Reply  24 Nov 2024, Pavel Murat, Bug Report, ODB lock timeout, Difficulty running MIDAS on Rocky 9.4 
there is a really good software tool developed by the Fermilab DAQ group, called TRACE - 

https://github.com/art-daq/trace ,
Entry  21 Nov 2024, Mann Gandhi, Info, What do the status numbers mean and where can I find more information about them? 
Hello, 

This is the error message I got:
    Reply  21 Nov 2024, Stefan Ritt, Info, What do the status numbers mean and where can I find more information about them? 

> [RP Streaming Frontend,ERROR] [midas.cxx:17806:cm_write_event_to_odb,ERROR] 
> cannot create key for bank "DATA" with tid 24 in ODB, db_create_key() status 309
Entry  13 Nov 2024, Stefan Ritt, Info, New sequencer command ODBLOOKUP 
A new sequencer command "ODBLOOKUP" has been implemented, which does a lookup of a string in a string 
array in the ODB given by a path and returns its index as a number. If we have for example an array
    Reply  15 Nov 2024, Konstantin Olchanski, Info, New sequencer command ODBLOOKUP 
> A new sequencer command "ODBLOOKUP" has been implemented, which does a lookup of a string in a string 
> array in the ODB given by a path and returns its index as a number. If we have for example an array
       Reply  18 Nov 2024, Stefan Ritt, Info, New sequencer command ODBLOOKUP 
> "value not found" sets "index" to ?

It sets it actually to "not found". Since all variables are stings in the sequencer, you can then do a test like
Entry  14 Nov 2024, Mann Gandhi, Suggestion, Issue with creating banks Screenshot_from_2024-11-14_12-35-06.png
Hello, I am a coop student working at SNOLAB. I am currently setting up a frontend 
program to collect data for an experiment I am currently having with my bank being 
initialized correctly with the correct name. I will attach an image of the error and 
    Reply  14 Nov 2024, Stefan Ritt, Suggestion, Issue with creating banks 
All I can see is that your bank header gets corrupted along the way. The funny character reported by 
cm_write_event_to_odb indicates that your original name "RPD0" got overwritten somewhere, but I could not spot any 
mistake in your code. 
       Reply  14 Nov 2024, Mann Gandhi, Suggestion, Issue with creating banks 
> All I can see is that your bank header gets corrupted along the way. The funny character reported by 
> cm_write_event_to_odb indicates that your original name "RPD0" got overwritten somewhere, but I could not spot any 
> mistake in your code. 
    Reply  15 Nov 2024, Konstantin Olchanski, Suggestion, Issue with creating banks 
> Hello, I am a coop student working at SNOLAB.
> void* data_acquisition_thread(void* param)
> {
Entry  07 Nov 2024, Lukas Gerritzen, Suggestion, Stop run and sequencer button 
Due to popular demand among our students, I added a button to the sequencer that stops the run and the sequence. If you find it useful, please consider
merging this upstream.
    Reply  07 Nov 2024, Stefan Ritt, Suggestion, Stop run and sequencer button 
I don't find this very useful. Some experiments do not only want to stop the run, but also do other cleanup things. To do that, I proposed and "atexit"
function like C has it. Then the user can put a run stop there, plus any other cleanup. This will be much more flexible. Think about the "reset" script
we have to manually run if we abort a sequencer. The atexit function will come next week, so you should consider to use it instead your additional button.
Entry  05 Nov 2024, Jack Carlton, Forum, How to properly write a client listens for events on a given buffer? data_pipeline_(2).cxxMidasConnector.cppmain.cpp
If there's some template for writing a client to access event data, that would be 
very useful (and you can probably just ignore the context I gave below in that 
case).
    Reply  05 Nov 2024, Maia Henriksson-Ward, Forum, How to properly write a client listens for events on a given buffer? 
> If there's some template for writing a client to access event data, that would be 
> very useful (and you can probably just ignore the context I gave below in that 
> case).
Entry  28 Oct 2024, Lukas Gerritzen, Bug Report, Visual glitch in history system Screen_Recording_2024-10-28_at_17.23.57.movScreenshot_2024-10-28_at_17.29.34.png
Today, I encountered the bug shown in the attached video. The value of the plotted curve does not match the mouseover number.

When trying to understand it better, I stopped being able to replicate. Has anyone else observed a similar problem? 
Entry  11 Oct 2024, Denis Calvet, Bug Report, Frontend name must differ from others by more than the last three characters 
Hi,
I have developed two Midas front-end programs for different hardware. The frontend_name of the first one is "FSCD_SC" (slow control) and that of the second
one is "FSCD_PS" (power supply).
    Reply  11 Oct 2024, Stefan Ritt, Bug Report, Frontend name must differ from others by more than the last three characters 
Hi Denis,

indeed a bug. Will fix it next week.
       Reply  18 Oct 2024, Stefan Ritt, Bug Report, Frontend name must differ from others by more than the last three characters 
Fixed and committed.

Best,
Entry  09 Oct 2024, Lukas Gerritzen, Suggestion, odbedit minor quality of life 
I have made two minor quality of life changes to odbedit.
[LIST]
[*] cd command: Typing cd without arguments now changes the directory to /, similar to the behaviour of the cd command in Linux sending you to the home
    Reply  09 Oct 2024, Stefan Ritt, Suggestion, odbedit minor quality of life 
Ok, accepted, done and pushed.

Stefan
Entry  05 Sep 2024, Jack Carlton, Forum, Python frontend rate limitations? frontend.pyfrontend.cxx
I'm trying to get a sense of the rate limitations of a python frontend. I 
understand this will vary from system to system.
    Reply  05 Sep 2024, Ben Smith, Forum, Python frontend rate limitations? 
> What limits the rate that poll_func is called in a python frontend? 

First the general advice: if you reduce the "period" of your equipment, then your function will get called more frequently. You can set it to 0 and we'll
       Reply  05 Sep 2024, Stefan Ritt, Forum, Python frontend rate limitations? 
> First the general advice: if you reduce the "period" of your equipment, then your function will get called more frequently. 
> You can set it to 0 and we'll call it as often as possible. You can set this in the ODB at "/Equipment/Python Data Simulator/Common/Period"
          Reply  06 Sep 2024, Jack Carlton, Forum, Python frontend rate limitations? 
Thanks for the responses, they were very helpful.

>First the general advice: if you reduce the "period" of your equipment, then your function will get called more frequently. You can set it to 0 and we'll
          Reply  11 Sep 2024, Konstantin Olchanski, Forum, Python frontend rate limitations? 

> poll(INT count) {
>    for (i=0 ; i<count ; i++)
       Reply  27 Sep 2024, Ben Smith, Forum, Python frontend rate limitations? 
> in your case the limitation is likely that you're sending 1.25MB per event and we have a lot of data marshalling to do between the python and C++ layer.

> I'll add it to my to-do list to investigate improving the performance of medium-to-large events in the python code.
    Reply  11 Sep 2024, Konstantin Olchanski, Forum, Python frontend rate limitations? 
> I'm trying to get a sense of the rate limitations of a python frontend.

1) python is single-threaded, for ultimate performance, a MIDAS frontend (or any DAQ 
       Reply  11 Sep 2024, Konstantin Olchanski, Forum, Python frontend rate limitations? 
> > I'm trying to get a sense of the rate limitations of a python frontend.

forgot one more:
Entry  22 Jun 2024, Joseph McKenna, Suggestion, manalyzer thread safety and custom http IP binding 
Hi all, I hope this is the right place to post two pull requests, if not, please let me know where I should be submitting them

Both are fairly small changes, please see them listed below (more details written on the PRs themselves)
    Reply  05 Jul 2024, Joseph McKenna, Suggestion, shared pointers for more flexible memory managment of the analysis 'flow' and TMEvent 
> Hi all, I hope this is the right place to post two pull requests, if not, please let me know where I should be submitting them

> Both are fairly small changes, please see them listed below (more details written on the PRs themselves)
       Reply  05 Jul 2024, Joseph McKenna, Suggestion, Clean up compiler warning in manalyzer 
This is a super small pull request, simple replace deprecated sprintf with snprintf

https://bitbucket.org/tmidas/manalyzer/pull-requests/9
          Reply  13 Sep 2024, Konstantin Olchanski, Suggestion, Clean up compiler warning in manalyzer 
> This is a super small pull request, simple replace deprecated sprintf with snprintf
> https://bitbucket.org/tmidas/manalyzer/pull-requests/9
             Reply  20 Sep 2024, Joseph McKenna, Suggestion, Clean up compiler warning in manalyzer 
> > This is a super small pull request, simple replace deprecated sprintf with snprintf
> > https://bitbucket.org/tmidas/manalyzer/pull-requests/9
                Reply  20 Sep 2024, Stefan Ritt, Suggestion, Clean up compiler warning in manalyzer 
> I like the look of std::format, looks cleaner than string streams

I fully agree. String streams is a pain if you want to do zero-leading hex output mixed with decimal output. Yes it's easier to read if you don't know
                   Reply  24 Sep 2024, Konstantin Olchanski, Suggestion, Clean up compiler warning in manalyzer 
> > I like the look of std::format, looks cleaner than string streams

> I fully agree. String streams is a pain if you want to do zero-leading hex output mixed with decimal output. Yes it's easier to read if you don't know
    Reply  13 Sep 2024, Konstantin Olchanski, Suggestion, manalyzer thread safety and custom http IP binding 
> - Enable ROOT's thread safety when running in multithreaded mode
> This helps avoid users having to write their call to a global thread lock when calling ->Fill() on ROOT histograms and Trees
> https://bitbucket.org/tmidas/manalyzer/pull-requests/5