    Reply  19 Aug 2023, Stefan Ritt, Bug Report, Error accessing history files 
Still get the same error with the latest version:

3:28 [mhttpd,ERROR] [history_schema.cxx:2913:FileHistory::read_data,ERROR] Cannot read 
    Reply  12 Sep 2023, Stefan Ritt, Suggestion, Syntax highlighting for sequencer scripts 
I like the idea of syntax highlighting, but your solution is just for one editor which not everybody
is using. It would be better if the editor built into mhttpd for MSL files would have the possibility.
    Reply  13 Sep 2023, Stefan Ritt, Forum, Hide start and stop buttons 
Indeed the ODB settings are obsolete. Now that the status page is fully dynamic 
(JavaScript), it's much more powerful to modify the status.html page directly. You 
can not only hide the buttons, but also remove the run numbers, the running time, 
    Reply  13 Sep 2023, Stefan Ritt, Forum, Hide start and stop buttons 
> Hi Stefan,

> > Indeed the ODB settings are obsolete.
    Reply  14 Sep 2023, Stefan Ritt, Forum, Hide start and stop buttons 
> I believe the original "hide run start / stop" was added specifically for ND280 GSC MIDAS. I do not know 
> why it was removed. "hide pause / resume" is still there. I will restore them. Hiding logger channel 
> section should probably be automatic of there is no /logger/channels, I can check if it works and what 
    Reply  15 Sep 2023, Stefan Ritt, Forum, Hide start and stop buttons 
> I believe the original "hide run start / stop" was added specifically for ND280 GSC MIDAS. I do not know 
> why it was removed. "hide pause / resume" is still there. I will restore them. Hiding logger channel 
> section should probably be automatic of there is no /logger/channels, I can check if it works and what 
    Reply  20 Sep 2023, Stefan Ritt, Bug Report, epics fe "Start Command" 
Thanks for reporting this problem. It has been fixed today, so the start command is only written if it's emtpy.

Stefan
    Reply  26 Sep 2023, Stefan Ritt, Suggestion, scroll when browsing for a link 
> When making a link in the odb (web interface) a nice browser window pop's up. There is however not scrolling possible in the window. As a result, you
can not reach a odb key if it is nested to deeply. 
Entry  26 Sep 2023, Stefan Ritt, Info, mjsonrpc_db_save / mjsonrpc_db_load have been dropped 
The JavaScript function

mjsonrpc_db_save / mjonrpc_db_load
    Reply  01 Oct 2023, Stefan Ritt, Bug Report, ODB page and hex values 
Thanks for reporting this bug, I fixed it in the last commit.

Best,
Entry  06 Oct 2023, Stefan Ritt, Info, New equipment display 
Since a long time we tried to convert all "static" mhttpd-generated pages to 
dynamic JavaScript. With the new history panel editor we were almost there. Now I 
committed the last missing piece - the equipment display. This is shown when you 
    Reply  09 Oct 2023, Stefan Ritt, Info, New equipment display Screenshot_2023-10-09_at_21.56.25.png
An additional functionality has been implemented on the equipment table:

You can now select several elements by Ctrl/Shift-Click on their names, then change the 
    Reply  24 Oct 2023, Stefan Ritt, Forum, Device with inputs and outputs 
The "multi" class driver takes care of that. It properly calls the SET and GET functions 
with the correct index. The code for that is in multi.cxx:105:
    Reply  13 Nov 2023, Stefan Ritt, Forum, mlogger does not HAVE_ROOT 
When you do "cmake .." in the build directory, you will see

-- MIDAS: Found ROOT version xxx in yyy
    Reply  14 Nov 2023, Stefan Ritt, Forum, mlogger does not HAVE_ROOT 
No, I'm not aware of this problem, but I suspect that your events somehow got corrupted. You can try the mdump utility
or the "Event Dump" web page to peek into your events, maybe you see an issue there. To give you more detailed information,
I would have to reproduce your problem, which is probably hard without your hardware.
    Reply  22 Nov 2023, Stefan Ritt, Forum, Polled frontend writes data to ODB without RO_ODB 
I cannot confirm that. I just tried myself with examples/experiment/frontend.cxx, removed the RO_ODB, and the trigger events did NOT get copied to the ODB.

Actually you can debug the code yourself. The relevant line is in mfe.cxx:2075:
    Reply  22 Nov 2023, Stefan Ritt, Forum, run number from an external (*SQL) db? 
> - multiple subdetectors are taking test data during early commissioning 
> - a postgres db is a single sorce of run numbers.
> - test runs taken by different subsystems are assigned different [unique] run numbers and 
    Reply  02 Dec 2023, Stefan Ritt, Forum, run number from an external (*SQL) db? 
> Stefan, I don't think we're talking 'mis-use' - rather different subdetectors being commisisoned 
> at different locations, on an uncorrelated schedule, using independent run control (RC) instances. 
> At this point in time, we can't use a common RC instance. 
    Reply  02 Dec 2023, Stefan Ritt, Forum, MIDAS state machine : how to get around w/o 'configured' state?  muegamma.msl
> The MIDAS state machine doesn't seem to have a state in between 'initialized' and 
> 'running'.
> In a larger detectors with multiple subsystems, the DAQ systems often have one more state:
    Reply  04 Dec 2023, Stefan Ritt, Forum, run number from an external (*SQL) db? 
> - how does one communicate with an external shell script from MSL ? I looked at the MIDAS Sequencer page 
>   
>   https://daq00.triumf.ca/MidasWiki/index.php/Sequencer