    Reply  26 May 2020, Pintaudi Giorgio, Forum, API to read MIDAS format file 
Eventually, I have settled for the SQLite format.
I could convert the MIDAS history files .hst to SQLite
database .sqlite3 using the utility mh2sql.
Entry  09 Sep 2016, Amy Roberts, Suggestion, AJAX jmsg "get messages since t" ability - add to docs? 
I recently needed to watch the Midas messages for a particular error - and 
thus needed a command to "get all the messages since a time t".
    Reply  09 Sep 2016, Suzannah Daviel, Suggestion, AJAX jmsg "get messages since t" ability - add to docs? 
> I recently needed to watch the Midas messages for a particular error - and 
> thus needed a command to "get all the messages since a time t".
    Reply  30 Sep 2016, Konstantin Olchanski, Suggestion, AJAX jmsg "get messages since t" ability - add to docs? 
> I recently needed to watch the Midas messages for a particular error - and 
> thus needed a command to "get all the messages since a time t".
Entry  04 Nov 2008, Suzannah Daviel, Suggestion, <odb ... edit=1> buttons and javascript  
When writing custom webpages, it would be nice to be able to write code such as

<odb src="/Equipment/TITAN_ACQ/ppg cycle/trans3/time offset (ms)" edit=1>
    Reply  09 Nov 2008, Stefan Ritt, Suggestion, <odb ... edit=1> buttons and javascript  
> When writing custom webpages, it would be nice to be able to write code such as

> <odb src="/Equipment/TITAN_ACQ/ppg cycle/trans3/time offset (ms)" edit=1>
Entry  25 Aug 2011, Francesco Prelz, Forum, 64-bit integer support in MIDAS 
Hi,

I've been doing some preliminary work to use at least the MIDAS
Entry  05 Jan 2016, Tom Stuttard, Suggestion, 64 bit bank type 
I've seen that a similar question has been asked in 2011 but I'll ask again in 
case there are any updates. Is there any way to write 64-bit data words to MIDAS 
banks (other than breaking them up in to two 32-bit words, such as 2 DWORDs) 
    Reply  05 Jan 2016, Konstantin Olchanski, Suggestion, 64 bit bank type 
> I've seen that a similar question has been asked in 2011 but I'll ask again in 
> case there are any updates. Is there any way to write 64-bit data words to MIDAS 
> banks (other than breaking them up in to two 32-bit words, such as 2 DWORDs) 
    Reply  15 Jan 2016, Tom Stuttard, Suggestion, 64 bit bank type 
> > I've seen that a similar question has been asked in 2011 but I'll ask again in 
> > case there are any updates. Is there any way to write 64-bit data words to MIDAS 
> > banks (other than breaking them up in to two 32-bit words, such as 2 DWORDs) 
    Reply  19 Jan 2016, Tom Stuttard, Suggestion, 64 bit bank type 
> > I've seen that a similar question has been asked in 2011 but I'll ask again in 
> > case there are any updates. Is there any way to write 64-bit data words to MIDAS 
> > banks (other than breaking them up in to two 32-bit words, such as 2 DWORDs) 
Entry  15 Jun 2021, Konstantin Olchanski, Info, 1000 Mbytes/sec through midas achieved! 
I am sure everybody else has 10gige and 40gige networks and are sending terabytes of data before breakfast.

Myself, I only have one computer with a 10gige network link and sufficient number of daq boards to fill
    Reply  15 Jun 2021, Stefan Ritt, Info, 1000 Mbytes/sec through midas achieved! frontend.cxx
In MEG II we also kind of achieved this rate. Marco F. will post an entry soon to describe the details. There is only one thing 
I want to mention, which is our network switch. Instead of an expensive high-grade switch, we chose a cheap "Chinese" high-grade 
switch. We have "rack switches", which are collector switch for each rack receiving up to 10 x 1GBit inputs, and outputting 1 x 
    Reply  16 Jun 2021, Marco Francesconi, Info, 1000 Mbytes/sec through midas achieved! 
As reported by Stefan, in MEG II we have very similar ethernet throughputs.
In total, we have 34 crates each with 32 DRS4 digitiser chips and a single 1 Gbps readout link through a Xilinx Zynq SoC.
The data arrives in push mode without any external intervention, the only throttling being an optional prescaling on the trigger rate.
    Reply  18 Jun 2021, Konstantin Olchanski, Info, 1000 Mbytes/sec through midas achieved! 
> In MEG II we also kind of achieved this rate.
>
> Instead of an expensive high-grade switch, we chose a cheap "Chinese" high-grade switch.
    Reply  18 Jun 2021, Konstantin Olchanski, Info, 1000 Mbytes/sec through midas achieved! 
> ... MEG II ... 34 crates each with 32 DRS4 digitiser chips and a single 1 Gbps readout link through a Xilinx Zynq SoC.
>
> Zynq ... embedded ethernet MAC does not support jumbo frames (always read the fine prints in the manuals!)
Entry  09 Mar 2016, Konstantin Olchanski, Info, /Experiment/Edit on start/Edit Run number 
The MIDAS documentation here:
  https://midas.triumf.ca/MidasWiki/index.php/Edit-on-start_Parameters
is missing informaiton about this ODB entry:
Entry  26 Jan 2022, Frederik Wauters, Forum, .gz files 
I adapted our analyzer to compile against the manalyzer included in the midas repo.

All our data files are .mid.gz, which now fail to process :(
    Reply  26 Jan 2022, Konstantin Olchanski, Forum, .gz files 
> I adapted our analyzer to compile against the manalyzer included in the midas repo.
> TMReadEvent: error: short read 0 instead of -1193512213
    Reply  31 Jan 2022, Frederik Wauters, Forum, .gz files 
> > I adapted our analyzer to compile against the manalyzer included in the midas repo.
> > TMReadEvent: error: short read 0 instead of -1193512213