Entry  08 Jul 2021, Francesco Renga, Forum, Problem with python file reader 
Dear experts,
       while trying to readout a MIDAS file from a python script. I get the error below at the very first event. Any hint?
    Reply  09 Jul 2021, Ben Smith, Forum, Problem with python file reader 
Hi Francesco,

Can you send me an example file to look at please? Either attached to the elog or sent directly to bsmith@triumf.ca
Entry  26 Apr 2017, Francesco Renga, Forum, Problem with logger at run start 
Dear experts,
    we have a problem when trying to run a MIDAS DAQ which worked in the past on the same PC (but on a different
network). We get the following error messages when starting a new run:
    Reply  26 Apr 2017, Stefan Ritt, Forum, Problem with logger at run start 
Dear Francesco,

Your error (No route to host) typically means that you have a network problem outside of MIDAS. Your computer has to "find itself" and 
    Reply  26 Apr 2017, Francesco Renga, Forum, Problem with logger at run start 
Dear Stefan,
           thank you very much for your reply. We could finally fix the problem by replacing "scarlett" with "scarlett.localdomain" in our
hostname configuration file /etc/hostname (under debian).
    Reply  02 May 2017, Konstantin Olchanski, Forum, Problem with logger at run start 
> Wed Apr 26 23:03:12 2017 [mhttpd,ERROR] [midas.c:9106:rpc_client_connect,ERROR] cannot connect to host "scar
> lett", port 44858: connect() returned -1, errno 113 (No route to host)
Entry  14 Oct 2014, Konstantin Olchanski, Bug Report, Problem with EQ_USER 
If you use EQ_USER in mfe.c and have multiple threads writing into the ring buffer, you will have a big 
problem - the thread locking in the ring buffer code only works for a single writer thread and a single 
reader thread.
    Reply  15 Oct 2014, Stefan Ritt, Bug Report, Problem with EQ_USER 
Sure, each thread needs its own ring buffer for writing.

So I see that we need back the multiple-ring-buffer-readout-scheme even before MEG will start. So what you need is something like
    Reply  16 Oct 2014, Stefan Ritt, Bug Report, Problem with EQ_USER 
I restructured the front-end code to enable multiple readout threads for EQ_USER equipment. Last summer I was definitively interrupted during 
that work and left it in an half finished state, sorry for that.
Entry  10 Aug 2012, Carl Blaksley, Forum, Problem with CAMAC controlled by CES8210 and read out by CAEN V1718 VME controller 
Hello all,

I am trying to put together a system to read out several camac adc. The camac is
Entry  22 Feb 2016, ZiyiGuo, Forum, Problem with BLTRead 
Dear all,

I'm using MIDAS system and CAEN V1721 to digitize the waveform from photomultipliers ( 
    Reply  23 Feb 2016, Pierre-Andre Amaudruz, Forum, Problem with BLTRead 
> Dear all,

> I'm using MIDAS system and CAEN V1721 to digitize the waveform from photomultipliers ( 
    Reply  02 Mar 2016, ZiyiGuo, Forum, Problem with BLTRead 
> > Dear all,
> > 
> > I'm using MIDAS system and CAEN V1721 to digitize the waveform from photomultipliers ( 
Entry  26 Jun 2019, Hassan, Forum, Problem transferring fetest data from the remote frontend to the backend 
Hi again, we now have Midas installed on the Rpi (remote frontend machine) and
have managed to run Fetest on it. Now we are at a stage where we want to send
the Fetest data over to the Data Acquisition machine, which also has Midas
    Reply  26 Jun 2019, Konstantin Olchanski, Forum, Problem transferring fetest data from the remote frontend to the backend 
> Hi again, we now have Midas installed on the Rpi (remote frontend machine) and
> have managed to run Fetest on it. Now we are at a stage where we want to send
> the Fetest data over to the Data Acquisition machine ...
Entry  12 Mar 2019, Francesco Renga, Forum, Problem stopping every second run 
Dear all,
         I'm running a DAQ frontend and it works well if one single run is
taken. If I try to take a second run right after, the run is performed but, when
    Reply  13 Mar 2019, Konstantin Olchanski, Forum, Problem stopping every second run 
>          I'm running a DAQ frontend and it works well if one single run is
> taken. If I try to take a second run right after, the run is performed but, when
> stopping it, I get the error messages below. Any hint?
    Reply  02 Feb 2007, Exaos Lee, Bug Fix, Problem solved by Re-define _syscall0(...) 
OK, I searched and found that my kernel doesn't support "_syscall0" any more. So I patched the system.c as the following (from line 954):
[CODE]
    Reply  06 Feb 2007, Stefan Ritt, Bug Fix, Problem solved by Re-define _syscall0(...) 
[quote="Exaos Lee"]Maybe it's not the perfect way, but it works. :-)[/quote]

I changed it to:
Entry  14 Oct 2014, Konstantin Olchanski, Bug Report, Problem in mfe multithread equipments 
In the ALPHA experiment at CERN I found a problem in mfe.c handling of multithreaded equipments. This problem was in 
some forms introduced around May 2013 and around Aug 2013 (commit 
https://bitbucket.org/tmidas/midas/src/45984c35b4f7/src/mfe.c) (I hope I got it right).