Back Midas Rome Roody Rootana
  Midas DAQ System, Page 81 of 143  Not logged in ELOG logo
ID Date Author Topicdown Subject
  2286   11 Oct 2021 Konstantin OlchanskiForumtest
> > test, no email. K.O.
> 
> test reply, no email. K.O.

test attachment, no email. K.O.
Attachment 1: image.png
image.png
  2287   11 Oct 2021 Konstantin OlchanskiForumtest
> > > test, no email. K.O.
> > 
> > test reply, no email. K.O.
> 
> test attachment, no email. K.O.

test email. K.O.
  2288   11 Oct 2021 Konstantin OlchanskiForummidas forum updated, moved
The midas forum software (elogd) was updated to latest version and moved from our old server 
(ladd00.triumf.ca) to our new server (daq00.triumf.ca).

The following URLs should work:

https://daq00.triumf.ca/elog-midas/Midas/ (new URL)
https://midas.triumf.ca/elog/Midas/ (old URL, redirects to daq00)
https://midas.triumf.ca/forum (link from midas wiki)

The configuration on the old server ladd00.triumf.ca is quite tangled between
several virtual hosts and several DNS CNAMEs. I think I got all the redirects
correct and all old URLs and links in old emails & etc still work.

If you see something wrong, please reply to this message here or email me directly.

K.O.
  2291   22 Oct 2021 Francesco RengaForummhttpd error
Dear all,
      I am trying to make the MIDAS web server for my DAQ project accessible from other machines. In the ODB, I activated the necessary flags:

[local:CYGNUS_RD:S]/WebServer>ls
Enable localhost port           y
localhost port                  8080
localhost port passwords        n
Enable insecure port            y
insecure port                   8081
insecure port passwords         y
insecure port host list         y
Enable https port               y
https port                      8443
https port passwords            y
https port host list            n
Host list
                                localhost
Enable IPv6                     y
Proxy                           
mime.types

Following the instructions on the Wiki I enabled the SSL support. When running mhttpd, I get these messages:

Mongoose web server will use HTTP Digest authentication with realm "CYGNUS_RD" and password file "/home/cygno/DAQ/online/htpasswd.txt"
Mongoose web server will use the hostlist, connections will be accepted only from: localhost
Mongoose web server listening on http address "localhost:8080", passwords OFF, hostlist OFF
Mongoose web server listening on http address "[::1]:8080", passwords OFF, hostlist OFF
Mongoose web server listening on http address "8081", passwords enabled, hostlist enabled
[mhttpd,ERROR] [mhttpd.cxx:19166:mongoose_listen,ERROR] Cannot mg_bind address "[::0]:8081"
Mongoose web server will use https certificate file "/home/cygno/DAQ/online/ssl_cert.pem"
Mongoose web server listening on https address "8443", passwords enabled, hostlist OFF
[mhttpd,ERROR] [mhttpd.cxx:19166:mongoose_listen,ERROR] Cannot mg_bind address "[::0]:8443"

and the server is not accessible from other machines. Any suggestion to solve or better investigate this problem?

Thank you very much,
         Francesco
  2292   22 Oct 2021 Stefan RittForummhttpd error
> Enable IPv6                     y

Probably the IPv6 problem, see here elog:2269

I asked to turn off IPv6 by default, or at least mention this in the documentation,
but unfortunately nothing happened.

Stefan
  2293   25 Oct 2021 Francesco RengaForummhttpd error
It worked, thank you very much!

Francesco

> > Enable IPv6                     y
> 
> Probably the IPv6 problem, see here elog:2269
> 
> I asked to turn off IPv6 by default, or at least mention this in the documentation,
> but unfortunately nothing happened.
> 
> Stefan
  2294   25 Oct 2021 Francesco RengaForumLogger crash
Hello,
     I'm experiencing crashes of the mlogger program on the time scale of a couple 
of days. The only messages from MIDAS are:

05:34:47.336 2021/10/24 [mhttpd,INFO] Client 'Logger' (PID 14281) on database 
'ODB' removed by db_cleanup called by cm_periodic_tasks (idle 10.2s,TO 10s)
05:34:47.335 2021/10/24 [mhttpd,INFO] Client 'Logger' on buffer 'SYSMSG' removed 
by cm_periodic_tasks (idle 10.2s, timeout 10s)

Any suggestion to further investigate this issue?

Thank you very much,
         Francesco
  2295   25 Oct 2021 Stefan RittForumLogger crash
The short term solution would be to increase the logger timeout in the ODB under

/Programs/Logger/Watchdog timeout

and set it to 6000 (one minute). But that is curing just the symptoms. It would be 
interesting to understand the cause of this error. Probably the logger takes more than 10 
seconds to start or stop the run. The reason could be that the history grow too big (what 
we have right now in MEG II), or some disk problems. But that needs detailed debugging on 
the logger side.

Stefan
  2299   09 Nov 2021 Francesco RengaForumIssue in data writing speed
Dear all,
       I've a frontend writing a quite big bunch of data into a MIDAS bank (16bit output from a 4MP photo camera). 
I'm experiencing a writing speed problem that I don't understand. When the photo camera is triggered at a low rate (< 2 Hz) 
writing into the bank takes a very short time for each event (indeed, what I measure is the time to write and go back 
into the polling function). If I increase the rate to 4 Hz, I see that writing the first two events takes a sort time, 
but the third event takes a very long time (hundreds of ms), then again the fourth and fifth events are very fast, and 
the sixth is very slow. If I further increase the rate, every other event is very slow. The problem is not in the readout 
of the camera, because if I just remove the bank writing and keep the camera readout, the problem disappears. Can you 
explain this behavior? Is there any way to improve it?

Below you can also find the code I use to copy the data from the camera buffer into the bank. If you have any suggestion 
to improve it, it would be really appreciated.

Thank you very much,
          Francesco



  const char* pSrc = (const char*)bufframe.buf;

  for(int y = 0; y < bufframe.height; y++ ){

    //Copy one row
    const unsigned short* pDst = (const unsigned short*)pSrc;

    //go through the row
    for(int x = 0; x < bufframe.width; x++ ){

      WORD tmpData = *pDst++; 

      *pdata++ = tmpData;

    }

    pSrc += bufframe.rowbytes;

  }
 
  2300   09 Nov 2021 Hunter LoweForumMityCAMAC Login
Hello all,

I've recently acquired a MityCAMAC system that was built at TRIUMF and I'm 
having issues accessing it over ethernet.

The system: Ubuntu VM inside Windows 10 machine.

I've tried reconfiguring the network settings for the VM but nmap and arp/ip 
commands have yielded me no results in finding the crate controller. 

I was getting help from Pierre Amaudruz but I think he is now busy for some 
time. I have the mac address of the crate controller and its name. The 
controller seems to initialize fine inside of the CAMAC crate. The windows side 
of the workstation also tells me that an unknown network is in fact connected.

I suspect I either need to do something with an ssh key (which I thought we 
accomplished but maybe not), or perhaps the domain name in the controller needs 
to be changed. 

If anybody has experience working with MityARM I would appreciate any advice I 
could get.

Best,
Hunter Lowe
UNBC Graduate Physics
  2301   10 Nov 2021 Stefan RittForumIssue in data writing speed
Midas uses various buffers (in the frontend, at the server side before the SYSTEM buffer, the SYSTEM buffer itself, on the 
logger before writing to disk. All these buffers are in RAM and have fast access, so you can fill them pretty quickly. When
they are full, the logger writes to disk, which is slower. So I believe at 2 Hz your disk can keep up with your writing 
speed, but at 4 Hz (2x8MBx4=32 MB/sec) your disk starts slowing down the writing process. Now 32MB/s is pretty slow for
a disk, so I presume you have turned compression on which takes quite some time.

To verify this, disable logging. The disable compression and keep logging. Then report back here again.

> Dear all,
>        I've a frontend writing a quite big bunch of data into a MIDAS bank (16bit output from a 4MP photo camera). 
> I'm experiencing a writing speed problem that I don't understand. When the photo camera is triggered at a low rate (< 2 Hz) 
> writing into the bank takes a very short time for each event (indeed, what I measure is the time to write and go back 
> into the polling function). If I increase the rate to 4 Hz, I see that writing the first two events takes a sort time, 
> but the third event takes a very long time (hundreds of ms), then again the fourth and fifth events are very fast, and 
> the sixth is very slow. If I further increase the rate, every other event is very slow. The problem is not in the readout 
> of the camera, because if I just remove the bank writing and keep the camera readout, the problem disappears. Can you 
> explain this behavior? Is there any way to improve it?
> 
> Below you can also find the code I use to copy the data from the camera buffer into the bank. If you have any suggestion 
> to improve it, it would be really appreciated.
> 
> Thank you very much,
>           Francesco
> 
> 
> 
>   const char* pSrc = (const char*)bufframe.buf;
> 
>   for(int y = 0; y < bufframe.height; y++ ){
> 
>     //Copy one row
>     const unsigned short* pDst = (const unsigned short*)pSrc;
> 
>     //go through the row
>     for(int x = 0; x < bufframe.width; x++ ){
> 
>       WORD tmpData = *pDst++; 
> 
>       *pdata++ = tmpData;
> 
>     }
> 
>     pSrc += bufframe.rowbytes;
> 
>   }
>  
  2302   11 Nov 2021 Thomas LindnerForumMityCAMAC Login
Hi Hunter 

This sounds like a Triumf specific problem; 
not a MIDAS problem.  Please email me directly 
and we can try to solve this problem.

Thomas Lindner
TRIUMF DAQ


 Hello all,
> 
> I've recently acquired a MityCAMAC system 
that was built at TRIUMF and I'm 
> having issues accessing it over ethernet.
> 
> The system: Ubuntu VM inside Windows 10 
machine.
> 
> I've tried reconfiguring the network 
settings for the VM but nmap and arp/ip 
> commands have yielded me no results in 
finding the crate controller. 
> 
> I was getting help from Pierre Amaudruz but 
I think he is now busy for some 
> time. I have the mac address of the crate 
controller and its name. The 
> controller seems to initialize fine inside 
of the CAMAC crate. The windows side 
> of the workstation also tells me that an 
unknown network is in fact connected.
> 
> I suspect I either need to do something with 
an ssh key (which I thought we 
> accomplished but maybe not), or perhaps the 
domain name in the controller needs 
> to be changed. 
> 
> If anybody has experience working with 
MityARM I would appreciate any advice I 
> could get.
> 
> Best,
> Hunter Lowe
> UNBC Graduate Physics
  2303   19 Nov 2021 Jacob ThorneForumSequencer error with ODB Inc
Hi,

I am having problems with the midas sequencer, here is my code:

1  COMMENT "Example to move a Standa stage"
2  RUNDESCRIPTION "Example movement sequence - each run is one position of a single stage
3  
4  PARAM numRuns
5  PARAM sequenceNumber
6  PARAM RunNum
7  
8  PARAM positionT2
9  PARAM deltapositionT2
10 
11 ODBSet "/Runinfo/Run number", $RunNum
12 ODBSet "/Runinfo/Sequence number", $sequenceNumber
13 
14 ODBSet "/Equipment/Neutron Detector/Settings/Detector/Type of Measurement", 2
15 ODBSet "/Equipment/Neutron Detector/Settings/Detector/Number of Time Bins", 10
16 ODBSet "/Equipment/Neutron Detector/Settings/Detector/Number of Sweeps", 1
17 ODBSet "/Equipment/Neutron Detector/Settings/Detector/Dwell Time", 100000
18 
19 ODBSet "/Equipment/MTSC/Settings/Devices/Stage 2 Translation/Device Driver/Set Position", $positionT2
20 
21 LOOP $numRuns
22  WAIT ODBvalue, "/Equipment/MTSC/Settings/Devices/Stage 2 Translation/Ready", ==, 1
23  TRANSITION START
24  WAIT ODBvalue, "/Equipment/Neutron Detector/Statistics/Events sent", >=, 1
25  WAIT ODBvalue, "/Runinfo/State", ==, 1
26  WAIT ODBvalue, "/Runinfo/Transition in progress", ==, 0
27  TRANSITION STOP
28  ODBInc "/Equipment/MTSC/Settings/Devices/Stage 2 Translation/Device Driver/Set Position", $deltapositionT2
29 
30 ENDLOOP
31 
32 ODBSet "/Runinfo/Sequence number", 0

The issue comes with line 28, the ODBInc does not work, regardless of what number I put I get the following error:

[Sequencer,ERROR] [odb.cxx:7046:db_set_data_index1,ERROR] "/Equipment/MTSC/Settings/Devices/Stage 2 Translation/Device Driver/Set Position" invalid element data size 32, expected 4

I don't see why this should happen, the format is correct and the number that I input is an int.

Sorry if this is a basic question.

Jacob
  2306   02 Dec 2021 Stefan RittForumSequencer error with ODB Inc
Thanks for reporting that bug. Indeed there was a problem in the sequencer code which I fixed now. Please try the updated develop branch.

Stefan
  2309   16 Dec 2021 Zaher SalmanForumDevice driver for modbus
Dear all, does anyone have an example of for a device driver using modbus or modbus tcp to communicate with a device and willing to share it? Thanks.
  2310   26 Jan 2022 Frederik WautersForum.gz files
I adapted our analyzer to compile against the manalyzer included in the midas repo.

All our data files are .mid.gz, which now fail to process :(

frederik@frederik-ThinkPad-T550:~/new_daq/build/analyzer$ ./analyzer -e100 -s100 ../../run_backup_11783.mid.gz 
...
...n
Registered modules: 1
file[0]: ../../run_backup_11783.mid.gz
Setting up the analysis!
TMReadEvent: error: short read 0 instead of -1193512213

Which is in the TMEvent* TMReadEvent(TMReaderInterface* reader) class in the midasio.cxx file

Reading the unzipped files works. But we have always processed our .gz files directly, for the unzipping we would need ~2x disk space.

Am I doing something wrong? I see that there is some activity on lz4 in the midasio repo, is gunzip next?
  2311   26 Jan 2022 Konstantin OlchanskiForum.gz files
> I adapted our analyzer to compile against the manalyzer included in the midas repo.
> TMReadEvent: error: short read 0 instead of -1193512213

I think this problem is fixed in the latest version of midasio and manalyzer, but this update
was not pulled into midas yet. (Canada is in the middle of a covid wave since December).

What happens is you do not have the gzip library installed on your computer and
your analyzer is built without support for gzip.

The fix is done the hard way, the gzip library is no longer optional, but required.

You do not say what linux you use, so I cannot give exact instructions, but for:
ubuntu: apt -y install libz-dev
centos7: installed by default
centos8: installed by default
debian11/raspbian: same as ubuntu

K.O.
  2312   26 Jan 2022 Konstantin OlchanskiForumDevice driver for modbus
> Dear all, does anyone have an example of for a device driver using modbus or modbus tcp to communicate with a device and willing to share it? Thanks.

I have not seen any modbus devices recently, so all my code and examples are quite old.

Basic modbus/tcp communication driver is in the midas repo:

daq00:midas$ find . | grep -i modbus
./drivers/divers/ModbusTcp.cxx
./drivers/divers/ModbusTcp.h
daq00:midas$ 

This driver worked for communication to a modbus PLC (T2K/ND280/TPC experiment in Japan).

An example program to use this driver and test modbus communication is here:
https://bitbucket.org/expalpha/agdaq/src/master/src/modbus.cxx

Because at the end, we do not have any modbus devices in any recent experiment,
I do not have any example of using this driver in the midas frontend. Sorry.

K.O.
  2318   26 Jan 2022 Konstantin OlchanskiForumIssue in data writing speed
Francesco, when you say "writing an event is slow", do you mean it in the frontend
or in the output data file?

Stefan is quite right about the data file, it can take seconds between generating
an event in the frontend and seeing it written to the data file. (if compression
buffers are too big, an event can sit there forever, until pushed out by next events
or by run stop).

But maybe you see this on the frontend side.

What you are looking at is "real time" performance of the frontend and of the linux kernel.

The mfe.c frontend has many problems with real time performance, it can stall and take a long
time between calls to read_event(), for many reasons.

There are ways around that, but it is simpler to switch to the tmfe c++ frontend
that was designed for good real time performance.

In the tmfe frontend, if you use the polled equipment and enable the poll thread,
your frontend will be limited only by the linux kernel real time performance (i.e.
on a single-core CPU, other programs will delay execution of your frontend
and you will see it as long delays (usec, millisec) between calls to your read_event().

Next limit to real time performance (common to mfe.c and tmfe frontends) is the writing
of event data to the midas shared event buffer. One has to lock the shared memory semaphore
and this has to wait until other users of the event buffer finish their reading
or writing and unlock it. Arbitrary amount of time (usec, millisec, sec) can pass.
(there is also problems with "fairness" of the linux semaphores, a different story, again).

Making things more interesting, midas event buffers implement a write cache (default size 100 kbytes),
events smaller than the cache are quickly accumulated (no need to lock the shared memory semaphore),
them flushed to shared memory when cache is full. This is done to reduce the number
of shared memory semaphore locks per event, in the case of very high rate of very small events.

Solution to all this is to use 2 threads: read the data from hardware in one thread and write the data to midas
in a different thread. Between the threads would be an event fifo (circular buffer in mfe.c,
std::deque<EVENT> in tmfe c++ frontends).

For remote connected frontends, things are a bit different. Event data is written directly
into the TCP socket and as long as socket buffers are big enough, there is no real-time delays,
unless SYSTEM buffer is very congested and mserver does not read the TCP socket quickly enough.
So depending on event size, data rate and tcp socket buffer size, the extra 2nd thread
may not be necessary and poll thread real time performance may be good enough.

I hope this clarifies the situation somewhat.

K.O.

> Dear all,
>        I've a frontend writing a quite big bunch of data into a MIDAS bank (16bit output from a 4MP photo camera). 
> I'm experiencing a writing speed problem that I don't understand. When the photo camera is triggered at a low rate (< 2 Hz) 
> writing into the bank takes a very short time for each event (indeed, what I measure is the time to write and go back 
> into the polling function). If I increase the rate to 4 Hz, I see that writing the first two events takes a sort time, 
> but the third event takes a very long time (hundreds of ms), then again the fourth and fifth events are very fast, and 
> the sixth is very slow. If I further increase the rate, every other event is very slow. The problem is not in the readout 
> of the camera, because if I just remove the bank writing and keep the camera readout, the problem disappears. Can you 
> explain this behavior? Is there any way to improve it?
> 
> Below you can also find the code I use to copy the data from the camera buffer into the bank. If you have any suggestion 
> to improve it, it would be really appreciated.
> 
> Thank you very much,
>           Francesco
> 
> 
> 
>   const char* pSrc = (const char*)bufframe.buf;
> 
>   for(int y = 0; y < bufframe.height; y++ ){
> 
>     //Copy one row
>     const unsigned short* pDst = (const unsigned short*)pSrc;
> 
>     //go through the row
>     for(int x = 0; x < bufframe.width; x++ ){
> 
>       WORD tmpData = *pDst++; 
> 
>       *pdata++ = tmpData;
> 
>     }
> 
>     pSrc += bufframe.rowbytes;
> 
>   }
>  
  2320   26 Jan 2022 Konstantin OlchanskiForumIssue in data writing speed
> Francesco, when you say "writing an event is slow", do you mean it in the frontend
> or in the output data file?

Another explanation just occurred to me. We do not know your event size and we do not
know the size of your SYSTEM buffer. But if you have an unlucky combination,
this can happen:

Consider event size is 6 Mbytes, buffer size is 8 Mbytes, enough space for only 1 event.

First event is written quickly (buffer is empty).
Second event will be delayed, there is not enough free space in the buffer, we have
to wait for mlogger to finish reading the first event.

Same thing happens if event size is 3 Mbytes, the first 2 events will write quickly,
writing the 3rd event will be delayed until mlogger does it's thing.

The mlogger reads the SYSTEM buffer "fast" and "quickly", but it can be delayed
for a number of reasons, i.e. handling a history event, a delay writing to disk,
a delay writing to network connected storage, etc.

In general, it is best to size the SYSTEM buffer to hold about 1 second worth
of data (of average size, average rate). If your event size is 4 Mbytes, and you
record them at 10/sec, SYSTEM buffer should be at least 40 Mbytes big. (this is
set in ODB /Experiment/Buffer Sizes). (MIDAS event buffer size is limited to 2 GBytes).

K.O.
ELOG V3.1.4-2e1708b5