Entry  24 Jun 2021, Konstantin Olchanski, Bug Fix, changes in history plots 
    Reply  24 Jun 2021, Stefan Ritt, Bug Fix, changes in history plots 
       Reply  25 Jun 2021, Marco Francesconi, Bug Fix, changes in history plots 
          Reply  25 Jun 2021, Konstantin Olchanski, Bug Fix, changes in history plots 
       Reply  25 Jun 2021, Konstantin Olchanski, Bug Fix, changes in history plots 
          Reply  25 Jun 2021, Konstantin Olchanski, Bug Fix, changes in history plots 
    Reply  25 Jun 2021, Stefan Ritt, Bug Fix, changes in history plots 
       Reply  25 Jun 2021, Konstantin Olchanski, Bug Fix, changes in history plots 
    Reply  30 Jun 2021, Konstantin Olchanski, Bug Fix, changes in history plots 
       Reply  14 Jul 2021, Konstantin Olchanski, Bug Fix, changes in history plots 
          Reply  14 Jul 2021, Konstantin Olchanski, Bug Fix, changes in history plots 
             Reply  24 Aug 2021, Stefan Ritt, Bug Fix, changes in history plots 
Message ID: 2237     Entry time: 25 Jun 2021     In reply to: 2231     Reply to this: 2238
Author: Konstantin Olchanski 
Topic: Bug Fix 
Subject: changes in history plots 
> I disagree ...

I am happy with disagreement and differences of opinions. Zest of life, driver of progress and improvements, etc.

I am even more happy with solutions to problems. The current problem is that the offset and factor feature
of history plots has been removed without much discussion.

I stress, we have been using this feature to run experiments for the last 20 years.

I do not understand objections to it being restored. If you do not want to use it, do not use it.

K.O.

> with the proposed change to scale the HV current for a "nice" display. If values are scaled, the axis should be 
> scaled in the same way. Otherwise people might read the current from the plot, look at the axis, and again get the wrong 
> value (the factor of 25x you mention). Sure you can hover with the cursor over the graph, and see the right value, but think 
> of taking a screen shot, putting this into a publication, and get complaints from the reviewer.
> 
> The only "correct" way in my opinion is to implement two vertical axis, as can be seen in some papers. One for the HV, and a 
> new TBD right axis for the current values, then indicating for each graph if the left or right vertical axis applies. For 
> the secondary axis we can have autoscaling or fixed scaling, as we have for the primary axis.
> 
> Stefan