Hi all,
thank you for all responses. 

It seems that there's no problem running MIDAS with event builder assembling
data from ~10 front-ends. How about ~100? One possible solution is to have a
multi-tiered architecture. 

The reason I am asking is that we are in the process of designing an Ethernet
based DAQ system with front-ends running on embedded computers (Linux/ARM
CPU/Xilinix FPGA) and MIDAS is one of my options as a DAQ framework.
I am open for advice/suggestions.

Thanks again
  Piotr