    Reply  28 Apr 2023, Konstantin Olchanski, Suggestion, Maximum ODB size 
> > Is this maybe related to what Stefan said about the run start - so that odbedit needs some time to load the bigger ODB?

> At the run start mlogger writes the ODB to the .mid file. This needs conversion (binary ODB -> XML ASCII) which can take time.
    Reply  09 Jun 2023, Konstantin Olchanski, Suggestion, Maximum ODB size 
> > 1) The ODB shared memory is dumped into a binary file (".ODB.SHM") after the last client finished ...

correction: ODB shared memory is saved to .ODB.SHM each time a client stops, this is db_close_database().
    Reply  12 Jun 2023, Stefan Ritt, Suggestion, Maximum ODB size 
> correction: ODB shared memory is saved to .ODB.SHM each time a client stops, this is db_close_database().

The original design of the midas shared memory (back in the 1990's) was that the ODB shared memory file gets
    Reply  12 Jun 2023, Konstantin Olchanski, Suggestion, Maximum ODB size 
> > correction: ODB shared memory is saved to .ODB.SHM each time a client stops, this is db_close_database().

> The original design of the midas shared memory (back in the 1990's) was that the ODB shared memory file gets
    Reply  13 Jun 2023, Stefan Ritt, Suggestion, Maximum ODB size 
> I remember the same, but I tracked it down in git to the very first commit, and there is no if() there,
> odb is saved to .ODB.SHM on every client shutdown, not just the last client. I guess we both misremebered.
    Reply  13 Jun 2023, Marius Koeppel, Suggestion, Maximum ODB size 

> BTW, how do I resize the ODB. I remember we discussed this some time ago, and concluded that odbedit needs a resize flag. Has this even been 
> done? If not, what is the "official" way to resize the ODB. We had some documentation about that some time ago, but I can't find it anymore.
    Reply  13 Jun 2023, Konstantin Olchanski, Suggestion, Maximum ODB size 
> > I remember the same, but I tracked it down in git to the very first commit, and there is no if() there,
> > odb is saved to .ODB.SHM on every client shutdown, not just the last client. I guess we both misremebered.
    Reply  13 Jun 2023, Konstantin Olchanski, Suggestion, Maximum ODB size 
> > BTW, how do I resize the ODB.

ODB cannot be resized "online". Everything has to stop, save content to odb.json, get rid of old ODB.SHM, ensure ODB shared memory is destroyed (SysV or
    Reply  13 Jun 2023, Stefan Ritt, Suggestion, Maximum ODB size 

> small problem. build an experiment, start taking data, observe how ODB is never saved to disk because the "last client" never stops. as bonus, crash
    Reply  13 Jun 2023, Konstantin Olchanski, Suggestion, Maximum ODB size 

> > small problem. build an experiment, start taking data, observe how ODB is never saved to disk because the "last client" never stops. as bonus, crash
    Reply  13 Jun 2023, Stefan Ritt, Suggestion, Maximum ODB size 

> are you sure? when/how often does "last midas program finishes" happen? it does not happen on a system crash, not on power loss, not on "shutdown -r
now" 
    Reply  15 Jun 2023, Konstantin Olchanski, Suggestion, Maximum ODB size 

> > are you sure? when/how often does "last midas program finishes" happen? it does not happen on a system crash, not on power loss, not on "shutdown -r
now" 
    Reply  28 Jul 2023, Stefan Ritt, Suggestion, Maximum ODB size 
> RFE filed:
> https://bitbucket.org/tmidas/midas/issues/367/odb-should-be-saved-to-disk-periodically
    Reply  09 Aug 2023, Konstantin Olchanski, Suggestion, Maximum ODB size 
> > RFE filed:
> > https://bitbucket.org/tmidas/midas/issues/367/odb-should-be-saved-to-disk-periodically
Entry  06 Jun 2004, Konstantin Olchanski, , Makefile: set -rpath 
I commited Makefile bits to set the RPATH on dynamically linked executables
to find libmidas.so and ROOT shared libraries without setting
LD_LIBRARY_PATH , etc. K.O.
Entry  28 Jun 2020, Konstantin Olchanski, Info, Makefile update 
I reworked the MIDAS Makefile to simplify things and to remove redundancy with functions 
provided by cmake.
    Reply  15 Jul 2020, Stefan Ritt, Info, Makefile update 
Please note that you can also compile midas in the standard cmake way with

$ mkdir build
Entry  10 May 2023, Lukas Gerritzen, Suggestion, Make sequencer more compatible with mobile devices 
When trying to select a run script on an iPad or other mobile device, you cannot enter subdirectories. This is caused by the following part:

[CODE]
    Reply  10 May 2023, Stefan Ritt, Suggestion, Make sequencer more compatible with mobile devices 
[quote="Lukas Gerritzen"]When trying to select a run script on an iPad or other mobile device, you cannot enter subdirectories. This is caused by the following
part:
[/quote]
Entry  11 Jul 2011, Konstantin Olchanski, Info, Make "STOP" run transition always succeed 
Over the years, there was some back-and-forth changes in what happens to run transitions when some 
of the participants misbehave (do not respond to RPC calls, timeout, crash, etc).