Entry  19 Feb 2008, Petr Nomokonov, Info, Frontend - Backend c onnection 
Backend computer with SLC4.4 Linux did'not work as mserver because some security
protection under iptables service (could not connect with frontend computers).
The connection established if to make ( under root ) iptables disable
Entry  26 Jan 2007, Carl Metelko, Forum, Front end electronics broadcast data over ethernet, can midas read this in 
Hi,
   the system I'm building will have data read into the frontend nodes
via ethernet (optic). Is this possible?>
Entry  26 Feb 2007, Stefan Ritt, Info, Fragmented polled events 
Fragmented polled events have been implemented in SVN revision 3625.
Fragmentation is a method of breaking down large (>MB) events into smaller
pieces and send them through the shared memory buffers, reassembling them at the
Entry  05 Sep 2006, Konstantin Olchanski, Forum, Forums moved from dasdevpc.triumf.ca to ladd00.triumf.ca 
For the record, the MIDAS (& co) forums have been physically moved from
dasdevpc.triumf.ca to our new server machine ladd00.triumf.ca. This change
should be transparent to all users, but if anything stops working, please let me
Entry  29 Jan 2020, Pintaudi Giorgio, Info, Force triggering of idle routine of a frontend 
Hello!
As you know, the generic MIDAS frontend has a class driver, device driver, bus driver
structure. Assuming a slow device frontend, its class driver should have a routine of type   
    Reply  02 Feb 2020, Konstantin Olchanski, Info, Force triggering of idle routine of a frontend 
Hi, Giorgio - I think you encountered a fundamental problem with what to do at the begin of 
run. There are two ways of thinking about it.
    Reply  02 Feb 2020, Pintaudi Giorgio, Info, Force triggering of idle routine of a frontend 
Dear Konstantin,
thank you very much for the explanation. I already have an idea of how to solve my problem by bypassing the class driver altogether or by slightly modifying
the mfe.cxx frontend.
    Reply  03 Feb 2020, Stefan Ritt, Info, Force triggering of idle routine of a frontend 
It is important to note that slow control readout and sending of midas events are two separate things. Readout is done as fast as possible, even multi-threaded
if selected. On fast devices this can be 100 Hz readout rate and even more. This data is stored in an internal buffer. When one of the values changes by
more than the update threshold, then the ODB gets updated. The midas events are composed from this internal buffer when a new event has to be sent. This
    Reply  04 Feb 2020, Pintaudi Giorgio, Info, Force triggering of idle routine of a frontend 
Dear Stefan,
thank you very much for the clarification. I knew about the DF_XXX flags and I am making good use of them in all my frontends. Anyway, what I really needed
was to change the readout rate depending on the run status (in particular DF_RUNNING or DF_TRANSITION).
    Reply  07 Feb 2020, Stefan Ritt, Info, Force triggering of idle routine of a frontend 
Dear Giorgio,

ok, now I'm slowly getting your point.
    Reply  07 Feb 2020, Pintaudi Giorgio, Info, Force triggering of idle routine of a frontend 
Dear Stefan,
Thank you for the advice. I will try to modify the driver as you say. As for the dynamical change of readout rate, basically you are telling me that is
not achievable without dirty hacks like mine and it is better to find a way to avoid it.
    Reply  09 Feb 2020, Stefan Ritt, Info, Force triggering of idle routine of a frontend 
You dirty hacks will probably work, but what you REALLY want is to read out your HV always as fast as possible, not only during run transitions or ramping.
We had a case where a detector produced electrostatic discharges which only lasted for a second or so, and we were happy to detect this in spikes in the
HV current. With measurements of only one per minute we would not have realized that so quicky.
    Reply  10 Feb 2020, Konstantin Olchanski, Info, Force triggering of idle routine of a frontend 
> We had a case where a detector produced electrostatic discharges which only lasted for a second or so
> and we were happy to detect this in spikes in the HV current. With measurements of only one per minute
> we would not have realized that so quicky.
    Reply  12 Feb 2020, Stefan Ritt, Info, Force triggering of idle routine of a frontend 
I had a look again at the issue. If you sett the event limit to zero in the EQUIPMENT list, then the idle() routine of your class driver is called as often
as possible. Typically with 100 Hz. It's then up to you what to do in the class driver. The hv_idle() routine of the HV class driver shipped in the distribution
for example read a channel more often if it has been changed recently. Look at the lines
Entry  10 May 2013, Konstantin Olchanski, Bug Fix, Fixed: crash if alarm "write elog message" is enabled 
If the MIDAS Alarm property "write elog message" is enabled, an uninitialized variable "tag" is passed to 
el_submit() and depending on your luck, cause a crash. "tag" is supposed to be and is now a NUL-
terminated string. The only other use of el_submit() is in mhttpd.cxx and mserver.c, where it is called 
Entry  15 Jan 2014, Konstantin Olchanski, Bug Fix, Fixed spurious symlinks to midas.log 
In some experiments (i.e. DEAP), we see spurious symlinks to midas.log scattered just about everywhere. I 
now traced this to an uninitialized variable in cm_msg_log() and it should be fixed now. K.O.
Entry  30 Oct 2003, Stefan Ritt, , Fixed several potential problems for ODB corruption 
I just realized that db_set_value, db_set_data, db_set_num_values and 
db_merge_data do not check for num_values == 0. With such a parameter the 
ODB can become corrupted, since zero length ODB entries are not allowed. I 
Entry  18 May 2006, Stefan Ritt, Bug Fix, Fixed problems with reload of custom pages 
We had a problem with custom pages and reloading of them. If they contain an ODB field which is editable, one can change the ODB value through the custom
page. The URL then contains a "?cmd=Set&value=x&index=x" section, which stays in the browser's address bar after the ODB value has been updated. If the
value changes later by some other means in the ODB, and one presses "reload" in the browser, the above URL gets executed again and the value gets changed
Entry  07 May 2009, Konstantin Olchanski, Bug Fix, Fixed mlogger run start and stop 
Fixed problems with mlogger starting and stopping runs.

Basic difficulty was with the mlogger using ASYNC transitions, which did not implement proper 
Entry  02 Nov 2017, Konstantin Olchanski, Bug Fix, Fixed mlogger memory corruption, updated mxml 
I the agdaq system I see memory corruption in the mlogger. There were at least two bugs: one 
memory allocation error in mxml and one incorrect memset() in mlogger.cxx. The mxml bug is fixed 
in the mxml repository, mlogger.cxx bug is fixed in the midas-2017-10 branch.