    Reply  18 Oct 2024, Stefan Ritt, Bug Report, Frontend name must differ from others by more than the last three characters 
Fixed and committed.

Best,
    Reply  18 Oct 2024, Konstantin Olchanski, Bug Report, Difficulty running MIDAS on Rocky 9.4 
> [aroberts@sdfcdmsdaq midas]$ odbedit
> [ODBEdit,ERROR] [odb.cxx:2043:db_open_database,ERROR] Removed ODB client 'ODBEdit', index 0 because process pid 
> 1615051 does not exists
    Reply  18 Oct 2024, Konstantin Olchanski, Bug Report, Difficulty running MIDAS on Rocky 9.4 
> suddenly, an ODB semaphore timeout...

I am wondering if something bizarre is going on, like the system clock going backwards. I heard of things like that 
Entry  23 Oct 2024, Lukas Gerritzen, Bug Report, ODB key picker does not close when creating link / Edit-on-run string box too large Screenshot_2024-10-23_at_11.38.38.png
To reproduce:
In the interactive ODB, click the 🔗 icon to create a link. Next to the target,  click the "..." button to open 
the key picker browser. Then try to close it by either:
Entry  28 Oct 2024, Lukas Gerritzen, Bug Report, Visual glitch in history system Screen_Recording_2024-10-28_at_17.23.57.movScreenshot_2024-10-28_at_17.29.34.png
Today, I encountered the bug shown in the attached video. The value of the plotted curve does not match the mouseover number.

When trying to understand it better, I stopped being able to replicate. Has anyone else observed a similar problem? 
    Reply  28 Oct 2024, Lukas Gerritzen, Bug Report, Visual glitch in history system Screenshot_2024-10-28_at_17.34.26.png
 
    Reply  28 Oct 2024, Amy Roberts, Bug Report, Difficulty running MIDAS on Rocky 9.4 
> Now for each timeout it will print detailed syscall and timing information, if time goes backwards, it should catch it.

It appears that time is moving forward:
    Reply  06 Nov 2024, Amy Roberts, Bug Report, Difficulty running MIDAS on Rocky 9.4 
After following Konstantin's debugging suggestions, I thought I would try to replicate 
the issue on my own computer.  My hope was that I could provide instructions for 
replicating the bug so that the MIDAS team could try debugging things more easily.
    Reply  22 Nov 2024, Konstantin Olchanski, Bug Report, ODB lock timeout, Difficulty running MIDAS on Rocky 9.4 
> try to replicate the issue ...

I see ODB lock timeout (and abort() of everything) in the dsvslice test station. We have 
    Reply  24 Nov 2024, Pavel Murat, Bug Report, ODB lock timeout, Difficulty running MIDAS on Rocky 9.4 
there is a really good software tool developed by the Fermilab DAQ group, called TRACE - 

https://github.com/art-daq/trace ,
Entry  26 Nov 2024, Nick Hastings, Bug Report, TMFE::Sleep() errors 
Hello,

I've noticed that SC FEs that use the TMFE class with midas-2022-05-c often report errors when calling TMFE:Sleep().
    Reply  26 Nov 2024, Maia Henriksson-Ward, Bug Report, TMFE::Sleep() errors 
> Hello,

> I've noticed that SC FEs that use the TMFE class with midas-2022-05-c often report errors when calling TMFE:Sleep().
    Reply  27 Nov 2024, Konstantin Olchanski, Bug Report, TMFE::Sleep() errors 
> [tmfe.cxx:1033:TMFE::Sleep,ERROR] select() returned -1, errno 22 (Invalid argument).

The very original copy of this function had an error and was spewing out this error quite often,
    Reply  27 Nov 2024, Konstantin Olchanski, Bug Report, TMFE::Sleep() errors 

> I wonder also if now that midas requires stricter/newer c++ standards if there maybe
> some more straightforward method to sleep that is sufficiently robust and portable.
    Reply  27 Nov 2024, Konstantin Olchanski, Bug Report, TMFE::Sleep() errors 
>       status = select(1, &fdset, NULL, NULL, &timeout);
>
>       On error, -1 is returned, ... timeout becomes undefined.
Entry  30 Nov 2024, Pavel Murat, Bug Report, EQ_PERIODIC-only equipment ?  
Dear Midas experts, 

I'm running into something which looks like an initialization problem. 
    Reply  01 Dec 2024, Stefan Ritt, Bug Report, EQ_PERIODIC-only equipment ?  
There is no requirement that you pair an EQ_PERIODIC with an EQ_TRIGGER. Take for exmaple

  midas/examples/experiment/frontend.cxx
    Reply  01 Dec 2024, Pavel Murat, Bug Report, EQ_PERIODIC-only equipment ?  
> There is no requirement that you pair an EQ_PERIODIC with an EQ_TRIGGER. Take for exmaple

>   midas/examples/experiment/frontend.cxx
    Reply  02 Dec 2024, Stefan Ritt, Bug Report, ODB key picker does not close when creating link / Edit-on-run string box too large 
> Actual result:
> The key picker does not close.
    Reply  02 Dec 2024, Stefan Ritt, Bug Report, ODB key picker does not close when creating link / Edit-on-run string box too large 
> Another more minor visual problem is the edit-on-start dialog. There seems to be no upper bound to the 
> size of the text box. In the attached screenshot, ShortString has a maximum length of 32 characters, 
> LongString has 255. Both are empty at the time of the screenshot. Maybe, the size should be limited to a 