2874
|
11 Oct 2024 |
Denis Calvet | Bug Report | Frontend name must differ from others by more than the last three characters | Hi,
I have developed two Midas front-end programs
for different hardware. The frontend_name |
|
2875
|
11 Oct 2024 |
Stefan Ritt | Bug Report | Frontend name must differ from others by more than the last three characters | Hi Denis,
indeed a bug. Will fix it next week.
|
|
2876
|
13 Oct 2024 |
Konstantin Olchanski | Bug Report | Difficulty running MIDAS on Rocky 9.4 | Thank you for the stack trace, I fixed the
buglet that cause midas programs to crash
twice,
|
|
2877
|
16 Oct 2024 |
Amy Roberts | Bug Report | Difficulty running MIDAS on Rocky 9.4 | > Thank you for the stack trace, I fixed the
buglet that cause midas programs to crash
twice,
|
|
2878
|
18 Oct 2024 |
Stefan Ritt | Bug Report | Frontend name must differ from others by more than the last three characters | Fixed and committed.
Best,
|
|
2879
|
18 Oct 2024 |
Konstantin Olchanski | Bug Report | Difficulty running MIDAS on Rocky 9.4 | > [aroberts@sdfcdmsdaq midas]$ odbedit
> [ODBEdit,ERROR] [odb.cxx:2043:db_open_database,ERROR]
Removed ODB client 'ODBEdit', index 0 because |
|
2880
|
18 Oct 2024 |
Konstantin Olchanski | Bug Report | Difficulty running MIDAS on Rocky 9.4 | > suddenly, an ODB semaphore timeout...
I am wondering if something bizarre is going |
|
2881
|
23 Oct 2024 |
Lukas Gerritzen | Bug Report | ODB key picker does not close when creating link / Edit-on-run string box too large | To reproduce:
In the interactive ODB, click the 🔗
icon to create a link. Next to the target, |
|
2882
|
28 Oct 2024 |
Lukas Gerritzen | Bug Report | Visual glitch in history system | Today, I encountered the bug shown in the
attached video. The value of the plotted
curve does not match the mouseover number.
|
 |
Draft
|
28 Oct 2024 |
Lukas Gerritzen | Bug Report | Visual glitch in history system | |
|
2884
|
28 Oct 2024 |
Amy Roberts | Bug Report | Difficulty running MIDAS on Rocky 9.4 | > Now for each timeout it will print detailed
syscall and timing information, if time goes
backwards, it should catch it.
|
|
2889
|
06 Nov 2024 |
Amy Roberts | Bug Report | Difficulty running MIDAS on Rocky 9.4 | After following Konstantin's debugging suggestions,
I thought I would try to replicate
the issue on my own computer. My hope was |
|
2902
|
22 Nov 2024 |
Konstantin Olchanski | Bug Report | ODB lock timeout, Difficulty running MIDAS on Rocky 9.4 | > try to replicate the issue ...
I see ODB lock timeout (and abort() of everything) |
|
2903
|
24 Nov 2024 |
Pavel Murat | Bug Report | ODB lock timeout, Difficulty running MIDAS on Rocky 9.4 | there is a really good software tool developed
by the Fermilab DAQ group, called TRACE -
|
|
2904
|
26 Nov 2024 |
Nick Hastings | Bug Report | TMFE::Sleep() errors | Hello,
I've noticed that SC FEs that use the TMFE |
|
2905
|
26 Nov 2024 |
Maia Henriksson-Ward | Bug Report | TMFE::Sleep() errors | > Hello,
>
> I've noticed that SC FEs that use the TMFE |
|
2906
|
27 Nov 2024 |
Konstantin Olchanski | Bug Report | TMFE::Sleep() errors | > [tmfe.cxx:1033:TMFE::Sleep,ERROR] select()
returned -1, errno 22 (Invalid argument).
|
|
2907
|
27 Nov 2024 |
Konstantin Olchanski | Bug Report | TMFE::Sleep() errors | >
> I wonder also if now that midas requires
stricter/newer c++ standards if there maybe
|
|
2908
|
27 Nov 2024 |
Konstantin Olchanski | Bug Report | TMFE::Sleep() errors | > status = select(1, &fdset, NULL, NULL,
&timeout);
>
|
|
2909
|
30 Nov 2024 |
Pavel Murat | Bug Report | EQ_PERIODIC-only equipment ? | Dear Midas experts,