Back Midas Rome Roody Rootana
  Midas DAQ System, Page 46 of 146  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Date Authordown Topic Subject Text Attachments
  2846   16 Sep 2024 Stefan RittBug ReportCrash using ODB watchThe answer is in the error message: „Object
went out of scope“. When your frontent_init()
exits, the odb objects are destroyed. When
  
  2848   16 Sep 2024 Stefan RittBug ReportCrash using ODB watchWell, the object *went* out of scope. For
my code it‘s hard to realize this, so the
error reporting is poor. Also the first object
  
  2853   20 Sep 2024 Stefan RittBug ReportCrash using ODB watchThe problem has been fixed in the current
version. Here is my analysis:
  
  2855   20 Sep 2024 Stefan RittSuggestionClean up compiler warning in manalyzer> I like the look of std::format, looks cleaner
than string streams
  
  2857   24 Sep 2024 Stefan RittInfoNews MSCB++ API> Where is the example of error handling?

#include "mscbxx.h"
  
  2872   09 Oct 2024 Stefan RittSuggestionodbedit minor quality of lifeOk, accepted, done and pushed.

Stefan
  
  2875   11 Oct 2024 Stefan RittBug ReportFrontend name must differ from others by more than the last three charactersHi Denis,

indeed a bug. Will fix it next week.
  
  2878   18 Oct 2024 Stefan RittBug ReportFrontend name must differ from others by more than the last three charactersFixed and committed.

Best,
  
  2891   07 Nov 2024 Stefan RittSuggestionStop run and sequencer buttonI don't find this very useful. Some experiments
do not only want to stop the run, but also
do other cleanup things. To do that, I proposed
  
  2892   13 Nov 2024 Stefan RittInfoNew sequencer command ODBLOOKUPA new sequencer command "ODBLOOKUP" has been
implemented, which does a lookup of a string
in a string 
  
  2894   14 Nov 2024 Stefan RittSuggestionIssue with creating banksAll I can see is that your bank header gets
corrupted along the way. The funny character
reported by 
  
  2898   18 Nov 2024 Stefan RittInfoNew sequencer command ODBLOOKUP> "value not found" sets "index" to ?

It sets it actually to "not found". Since
  
  2901   21 Nov 2024 Stefan RittInfoWhat do the status numbers mean and where can I find more information about them?
> [RP Streaming Frontend,ERROR] [midas.cxx:17806:cm_write_event_to_odb,ERROR]
  
  2910   01 Dec 2024 Stefan RittBug ReportEQ_PERIODIC-only equipment ? There is no requirement that you pair an EQ_PERIODIC
with an EQ_TRIGGER. Take for exmaple
  
  2912   02 Dec 2024 Stefan RittBug ReportODB key picker does not close when creating link / Edit-on-run string box too large> Actual result:
> The key picker does not close.
  
  2913   02 Dec 2024 Stefan RittBug ReportODB key picker does not close when creating link / Edit-on-run string box too large> Another more minor visual problem is the
edit-on-start dialog. There seems to be no
upper bound to the 
  
  2914   02 Dec 2024 Stefan RittForum"Safe" abort of sequencer scriptsThe atexit() function has been implemented
in the current develop branch of midas, see
  
  2917   06 Dec 2024 Stefan RittInfoNew slow control framework "mdev"A new slow control mini-framework has been
developed for MIDAS and been successfully
tested in the Mu3e experiment. It 
 PDCC.png 
  2920   10 Dec 2024 Stefan RittSuggestionComma-separated indices in alarm conditionsThese kind of alarm conditions have been implemented
and committed. The documentation at 
  
  2921   12 Dec 2024 Stefan RittSuggestionNew alarm sound flag to be testedWe had the case in MEG that some alarms were
actually just warnings, not very severe.
This happens for example if we calibrate
  
ELOG V3.1.4-2e1708b5