Entry  27 Dec 2006, Eric-Olivier LE BIGOT, Forum, Access to out_info from mana.c 
Hello,

Is it possible to access out_info (defined in mana.c) from another program?
Entry  11 Jan 2007, Steve Hardy, Forum, Shared memory problems 
Hello,

Just did a fresh install of MIDAS from the SVN repository under CentOS and
    Reply  11 Jan 2007, Stefan Ritt, Forum, Shared memory problems 
> Hello,

> Just did a fresh install of MIDAS from the SVN repository under CentOS and
    Reply  11 Jan 2007, Steve Hardy, Forum, Shared memory problems 
Thanks for your help.  I tried again and it got me back to the initial problem I had.
 The frontend will start, and the analyzer starts (complains about there not being a
last.root, but other than that it's fine), and then when starting mlogger, I get:
    Reply  11 Jan 2007, Stefan Ritt, Forum, Shared memory problems 
That sounds like you mix versions: You have an old executable (maybe your mlogger) which
has been linked against the old midas version, but you create the ODB with the new
odbedit or frontend. The new version complains if it finds an ODB from a previous version
Entry  22 Jan 2007, Carl Metelko, Forum, Midas on a x86_64 
Hi,
   has anyone managed to get midas to work on a x86_64 processor. I followed the
instructions for the 64-bit opteron but i am getting runtime error when trying
    Reply  22 Jan 2007, Konstantin Olchanski, Forum, Midas on a x86_64 
>    has anyone managed to get midas to work on a x86_64 processor. I followed the
> instructions for the 64-bit opteron but i am getting runtime error when trying
> the examples.
    Reply  26 Jan 2007, Carl Metelko, Forum, Midas on a x86_64 
I upgraded from 1.9.5 to the latest on SVN an it works fine
Entry  26 Jan 2007, Carl Metelko, Forum, Front end electronics broadcast data over ethernet, can midas read this in 
Hi,
   the system I'm building will have data read into the frontend nodes
via ethernet (optic). Is this possible?>
Entry  27 Feb 2007, Piotr Zolnierczuk, Forum, event builder scalability 
Hi there:
I have a question if there's anybody out there running MIDAS with event builder
that assembles events from more that just a few front ends (say on the order of
    Reply  27 Feb 2007, Stefan Ritt, Forum, event builder scalability 
> Hi there:
> I have a question if there's anybody out there running MIDAS with event builder
> that assembles events from more that just a few front ends (say on the order of
    Reply  27 Feb 2007, John M O'Donnell, Forum, event builder scalability 
At Los Alamos, we have 15+1 frontends - the 15 between them read about 2 or 3
TB/hour and reduce it to 1 to 5 GB/hour which is then sent to the mevb on a 17th
computer.  The 16th frontend handles deadtime issues and scalers (small data rate).
    Reply  27 Feb 2007, Stefan Ritt, Forum, event builder scalability 
> Our bottle neck is (a) compactPCI backplane reading data from waveform digitizers
> to the frontend CPUs and (b) CPU power on the frontend CPUs to analyzer the waveforms.
    Reply  02 Mar 2007, Kevin Lynch, Forum, event builder scalability 
> Hi there:
> I have a question if there's anybody out there running MIDAS with event builder
> that assembles events from more that just a few front ends (say on the order of
    Reply  03 Mar 2007, Piotr Zolnierczuk, Forum, event builder scalability 
Hi all,
thank you for all responses. 
    Reply  03 Mar 2007, Stefan Ritt, Forum, event builder scalability 
> It seems that there's no problem running MIDAS with event builder assembling
> data from ~10 front-ends. How about ~100? One possible solution is to have a
> multi-tiered architecture. 
Entry  10 Apr 2007, Dan Gastler, Forum, Interrupt code for VME? 
Hello, 
   Is there any example code for using midas for interrupt driven data
collection over VME? I am using a Struck SIS3100 PCI/VME setup to connect to my
Entry  09 May 2007, Carl Metelko, Forum, Splitting data transfer and control onto different networks 
Hi,
   I'm setting up a system with two networks with the intension of having
control info (odb, alarm) on the 192.168.0.x
    Reply  09 May 2007, Stefan Ritt, Forum, Splitting data transfer and control onto different networks 
Hi Carl,

so far I did not experience any problems of running odb&alarm on the same link as
    Reply  09 May 2007, Konstantin Olchanski, Forum, Splitting data transfer and control onto different networks 
> I'm setting up a system with two networks with the intension of having
> control info (odb, alarm) on the 192.168.0.x
> and the frontend readout on 192.168.1.x