ID |
Date |
Author |
Topic |
Subject |
Text |
 |
3024
|
02 Apr 2025 |
Konstantin Olchanski | Suggestion | Sequencer ODBSET feature requests | > I once looked at using LUA for this
>
> > but I think basing off an full featured |
|
3025
|
02 Apr 2025 |
Stefan Ritt | Suggestion | Sequencer ODBSET feature requests | And there is one more argument:
We have a Python expert in our development |
|
3026
|
07 Apr 2025 |
Zaher Salman | Suggestion | Sequencer ODBSET feature requests | [quote="Lukas Gerritzen"]
I also encountered a small annoyance in the
current workflow of editing sequencer files |
|
3027
|
07 Apr 2025 |
Stefan Ritt | Suggestion | Sequencer ODBSET feature requests | If people are simultaneously editing scripts
this is indeed an issue, which probably never
can be resolved by technical means. It need |
|
952
|
31 Jan 2014 |
Stefan Ritt | Info | Separation of MSCB subtree | Since several projects at PSI need MSCB but
not MIDAS, I decided to separate the two
repositories. So if you
|
|
960
|
18 Feb 2014 |
Konstantin Olchanski | Info | Separation of MSCB subtree | > Since several projects at PSI need MSCB
but not MIDAS, I decided to separate the
two repositories. So if you
|
|
530
|
26 Nov 2008 |
Jimmy Ngai | Info | Send email alert in alarm system | Dear All,
We have a temperature/humidity sensor in |
|
531
|
26 Nov 2008 |
Stefan Ritt | Info | Send email alert in alarm system | > We have a temperature/humidity sensor in
MIDAS now and will add a liquid level
> sensor to MIDAS soon. We want the operators |
|
1397
|
24 Sep 2018 |
Lars Martin | Suggestion | Self-resetting alarm class | I was planning to use the alarm system to
display an information banner when a
certain valve is open, but I would like it |
|
1398
|
24 Sep 2018 |
Lukas Gerritzen | Suggestion | Self-resetting alarm class | If you run an external script anyway, you
can also call "odbedit -c alarm" to
reset all alarms. Or you could try to set |
|
1399
|
25 Sep 2018 |
Stefan Ritt | Suggestion | Self-resetting alarm class | > If you run an external script anyway, you
can also call "odbedit -c alarm" to
> reset all alarms. Or you could try to set |
|
1400
|
25 Sep 2018 |
Stefan Ritt | Suggestion | Self-resetting alarm class | > I was planning to use the alarm system to
display an information banner when a
> certain valve is open, but I would like |
|
1422
|
26 Dec 2018 |
Konstantin Olchanski | Suggestion | Self-resetting alarm class | > > If you run an external script anyway,
you can also call "odbedit -c alarm" to
> > reset all alarms. Or you could try to |
|
2503
|
08 May 2023 |
Alexey Kalinin | Forum | Scrript in sequencer | Hello,
I tried different ways to pass parameters |
|
2504
|
08 May 2023 |
Stefan Ritt | Forum | Scrript in sequencer | > I tried different ways to pass parameters
to bash script, but there are seems to
> be empty, what could be the problem?
|
|
2505
|
09 May 2023 |
Alexey Kalinin | Forum | Scrript in sequencer | Thanks. It works perfect.
Another question is:
Is it possible to run .msl seqscript from |
|
2506
|
10 May 2023 |
Stefan Ritt | Forum | Scrript in sequencer | > Thanks. It works perfect.
> Another question is:
> Is it possible to run .msl seqscript from |
|
613
|
04 Aug 2009 |
Exaos Lee | Forum | Scripts to handle MIDAS sessions | Hi, all again
I have some scripts in "bash" and "Python" |
|
674
|
23 Nov 2009 |
Exaos Lee | Suggestion | Scripts for "midas-config" | Supposing you have installed MIDAS to some
directory such as "/opt/MIDAS/r4621", you
have to write some Makefile as the following |
 |
269
|
13 Jun 2006 |
Stefan Ritt | Info | Scheduler changed for slow control equipment | The schedule in mfe.c is used both for "normal"
front-ends and for "slow-control" front-ends.
Unfortunately it was only optimized for the |
|