    Reply  13 Aug 2017, Stefan Ritt, Suggestion, Increasing Max Number of Frontends 
The type INT has been defined in 1989 when I for the first time sent data between a 16-bit MS-DOS computer and a 32-bit VAX computer (good old 
days!). At that time, uint32_t was not available at all. So much for the historical background.
Entry  15 Nov 2017, Andreas Knecht, Suggestion, Feature request: Separate ODB flag to show programs on "Programs page" 
Currently one has to set the required flag in the ODB (e.g., /Programs/Logger/Required) to "y" for the program 
to appear on the "Programs page" and being able to start and stop the program easily.
    Reply  17 Nov 2017, Konstantin Olchanski, Suggestion, Feature request: Separate ODB flag to show programs on "Programs page" 
> Currently one has to set the required flag in the ODB (e.g., /Programs/Logger/Required) to "y" for the program 
> to appear on the "Programs page" and being able to start and stop the program easily.
    Reply  21 Nov 2017, Stefan Ritt, Suggestion, Feature request: Separate ODB flag to show programs on "Programs page" 
> > Currently one has to set the required flag in the ODB (e.g., /Programs/Logger/Required) to "y" for the program 
> > to appear on the "Programs page" and being able to start and stop the program easily.
> > 
Entry  16 Feb 2018, Amy Roberts, Suggestion, respect capitalization option in db_get_values mjsonrpc method? 
I'd like to use the mjsonrpc db_get_values method, but (as indicated in the
documentation) it returns all ODB keys as lowercase.
    Reply  17 Feb 2018, Amy Roberts, Suggestion, respect capitalization option in db_get_values mjsonrpc method? 
It appears I needed to read the documentation more closely - the method db_save
does respect key-name capitalization and solves my problem.
Entry  19 Feb 2018, Thomas Lindner, Suggestion, Rename sequencer program to msequencer 
Hi Folks,

In last year's updates to MIDAS, the MIDAS sequencer has been broken out as a
    Reply  05 Mar 2018, Thomas Lindner, Suggestion, Rename sequencer program to msequencer 
Hearing no objections I changed the name of the program to msequencer.  Wiki
documentation updated.
Entry  05 Mar 2018, , Suggestion,  
 
    Reply  08 Mar 2018, Thomas Lindner, Suggestion, respect capitalization option in db_get_values mjsonrpc method? 
Hi Amy,

Let me start by explaining the reasoning for the default behavior of db_get_values.  I think it was mentioned elsewhere, but is worth repeating.
Entry  08 Mar 2018, Suzannah Daviel, Suggestion, link to an array element displays whole array in mhttpd controlvar.png
A link to an array variable such as

[local:npet:Stopped]/>ls /rcparams/ControlVariables/
Entry  19 Mar 2018, Andreas Suter, Suggestion, check current ODB size 
A feature I always missed (or just missed to find in the docu) is the following:
1) It would be nice to have a command in odbedit which allows to check how full
the ODB currently is.
    Reply  19 Mar 2018, Stefan Ritt, Suggestion, check current ODB size 
> A feature I always missed (or just missed to find in the docu) is the following:
> 1) It would be nice to have a command in odbedit which allows to check how full
> the ODB currently is.
    Reply  19 Mar 2018, Andreas Suter, Suggestion, check current ODB size 
> > A feature I always missed (or just missed to find in the docu) is the following:
> > 1) It would be nice to have a command in odbedit which allows to check how full
> > the ODB currently is.
    Reply  19 Mar 2018, Stefan Ritt, Suggestion, check current ODB size 
> > > A feature I always missed (or just missed to find in the docu) is the following:
> > > 1) It would be nice to have a command in odbedit which allows to check how full
> > > the ODB currently is.
Entry  24 Sep 2018, Lars Martin, Suggestion, Self-resetting alarm class 
I was planning to use the alarm system to display an information banner when a
certain valve is open, but I would like it to go away again when the valve is
closed.
    Reply  24 Sep 2018, Lukas Gerritzen, Suggestion, Self-resetting alarm class 
If you run an external script anyway, you can also call "odbedit -c alarm" to
reset all alarms. Or you could try to set the "Triggered" entry of that certain
alarm to 0 (again, with odbedit), that could also work.
    Reply  25 Sep 2018, Stefan Ritt, Suggestion, Self-resetting alarm class 
> If you run an external script anyway, you can also call "odbedit -c alarm" to
> reset all alarms. Or you could try to set the "Triggered" entry of that certain
> alarm to 0 (again, with odbedit), that could also work.
    Reply  25 Sep 2018, Stefan Ritt, Suggestion, Self-resetting alarm class 
> I was planning to use the alarm system to display an information banner when a
> certain valve is open, but I would like it to go away again when the valve is
> closed.
    Reply  26 Dec 2018, Konstantin Olchanski, Suggestion, Self-resetting alarm class 
> > If you run an external script anyway, you can also call "odbedit -c alarm" to
> > reset all alarms. Or you could try to set the "Triggered" entry of that certain
> > alarm to 0 (again, with odbedit), that could also work.