    Reply  28 May 2020, Stefan Ritt, Suggestion, ODB++ API - documantion updates and odb view after key creation 
> 2. When I create an ODB structure with the new API I do for example:

>     midas::odb stream_settings = {
    Reply  30 May 2020, Stefan Ritt, Suggestion, ODB++ API - documantion updates and odb view after key creation 
Marius, has the problem been fixed in meantime?

Stefan
    Reply  04 Jun 2020, Marius Koeppel, Suggestion, ODB++ API - documantion updates and odb view after key creation 
Hi Stefan,

your test program was only working for me after I changed the following lines inside the odbxx.cpp
    Reply  05 Jun 2020, Stefan Ritt, Suggestion, ODB++ API - documantion updates and odb view after key creation 
Hi Marius,

your fix is good. Thanks for digging out this deep-lying issue, which would have haunted us if we would not fix it. 
    Reply  08 Jun 2020, Marius Koeppel, Suggestion, ODB++ API - documantion updates and odb view after key creation 
Hi Stefan,

I agree with your explanation about the size of BOOL and bool. 
    Reply  16 Jun 2020, Marius Koeppel, Suggestion, ODB++ API - documantion updates and odb view after key creation 
Hi Stefan,

I played around with the code a bit more and I found out that if I do:
    Reply  23 Jun 2020, Stefan Ritt, Suggestion, ODB++ API - documantion updates and odb view after key creation 
Hi Marius,

thanks for your help, you identified the problematic location. I changed that to
    Reply  24 Jun 2020, Marius Koeppel, Suggestion, ODB++ API - documantion updates and odb view after key creation 
Hi Stefan,

now everything works well (Tested on: OpenSuse and Arch Linux) :) 
Entry  30 Sep 2023, Gennaro Tortone, Bug Report, ODB page and hex values 10.png

Hi,
    Reply  01 Oct 2023, Stefan Ritt, Bug Report, ODB page and hex values 
Thanks for reporting this bug, I fixed it in the last commit.

Best,
    Reply  22 Nov 2024, Konstantin Olchanski, Bug Report, ODB lock timeout, Difficulty running MIDAS on Rocky 9.4 
> try to replicate the issue ...

I see ODB lock timeout (and abort() of everything) in the dsvslice test station. We have 
    Reply  24 Nov 2024, Pavel Murat, Bug Report, ODB lock timeout, Difficulty running MIDAS on Rocky 9.4 
there is a really good software tool developed by the Fermilab DAQ group, called TRACE - 

https://github.com/art-daq/trace ,
Entry  27 Nov 2007, Stefan Ritt, Info, ODB links to array elements implemented 
In revision 4090 I implemented ODB links to individual array elements. Now you
can have for example:
Entry  23 Oct 2024, Lukas Gerritzen, Bug Report, ODB key picker does not close when creating link / Edit-on-run string box too large Screenshot_2024-10-23_at_11.38.38.png
To reproduce:
In the interactive ODB, click the 🔗 icon to create a link. Next to the target,  click the "..." button to open 
the key picker browser. Then try to close it by either:
    Reply  02 Dec 2024, Stefan Ritt, Bug Report, ODB key picker does not close when creating link / Edit-on-run string box too large 
> Actual result:
> The key picker does not close.
    Reply  02 Dec 2024, Stefan Ritt, Bug Report, ODB key picker does not close when creating link / Edit-on-run string box too large 
> Another more minor visual problem is the edit-on-start dialog. There seems to be no upper bound to the 
> size of the text box. In the attached screenshot, ShortString has a maximum length of 32 characters, 
> LongString has 255. Both are empty at the time of the screenshot. Maybe, the size should be limited to a 
    Reply  04 Dec 2024, Konstantin Olchanski, Bug Report, ODB key picker does not close when creating link / Edit-on-run string box too large 
> > Actual result:
> > The key picker does not close.
    Reply  05 Dec 2024, Konstantin Olchanski, Bug Report, ODB key picker does not close when creating link / Edit-on-run string box too large 
> > Another more minor visual problem is the edit-on-start dialog. There seems to be no upper bound to the 
> > size of the text box. In the attached screenshot, ShortString has a maximum length of 32 characters, 
> > LongString has 255. Both are empty at the time of the screenshot. Maybe, the size should be limited to a 
Entry  18 Jun 2020, Ruslan Podviianiuk, Forum, ODB key length 
Hello,

I have a question about length of the name of ODB key.
    Reply  18 Jun 2020, Stefan Ritt, Forum, ODB key length 
No. But if you need more than 32 characters, you do something wrong. The 
information you want to put into the ODB key name should probably be stored in 
another string key or so.