Entry  28 Dec 2018, Konstantin Olchanski, Info, note on the midas event buffer code, part 1 
    Reply  28 Dec 2018, Konstantin Olchanski, Info, note on the midas event buffer code, part 2, bm_send_event() 
       Reply  28 Dec 2018, Konstantin Olchanski, Info, note on the midas event buffer code, part 3, rpc_send_event() 
          Reply  28 Dec 2018, Konstantin Olchanski, Info, note on the midas event buffer code, part 4, reading from event buffer 
             Reply  02 Jan 2019, Konstantin Olchanski, Info, note on the midas event buffer code, part 5, bm_read_buffer() 
                Reply  02 Jan 2019, Konstantin Olchanski, Info, note on the midas event buffer code, part 6, reading events through the mserver 
                   Reply  03 Jan 2019, Konstantin Olchanski, Info, note on the midas event buffer code, part 7, event buffer polling frequencies 
                      Reply  03 Jan 2019, Konstantin Olchanski, Info, note on the midas event buffer code, part 8, writer and reader communications 
                         Reply  10 Jan 2019, Konstantin Olchanski, Info, note on the midas event buffer code, part 8, writer and reader communications 
Message ID: 1428     Entry time: 28 Dec 2018     In reply to: 1427     Reply to this: 1429
Author: Konstantin Olchanski 
Topic: Info 
Subject: note on the midas event buffer code, part 3, rpc_send_event() 
> In this technical note, I write down the workings of the midas event buffer code
> we need to understand and write down how the event buffer code works.
> bm_send_event() does this ...

When connecting to midas remotely via the mserver, bm_send_event() works as expected through
the MIDAS RPC (RPC_BM_SEND_EVENT).

MIDAS RPC does a lot of work encoding and decoding the data, so for extra efficiency,
mfe-based frontends, use rpc_send_event().

rpc_send_event() does this:
- if we are connected locally, call bm_send_event()
- if rpc_mode==0, an RPC_BM_SEND_EVENT request is constructed "by hand" and sent to the mserver, result is same as calling 
bm_send_event() but overhead is reduced because we avoid calling the generic rpc_call().
- if rpc_mode!=0, event data is sent to the mserver by writing it into the event tcp connection (_server_connection.event_sock).
- there is a small (8kbyte) cache for batching tcp writes, probably not useful for modern tcp implementation, but it makes 
rpc_send_event() non thread-safe.

rpc_send_event() is NOT thread safe.

mserver receives event data in rpc_server_receive():
- read the data from the event tcp connection (_server_acception[idx].event_sock) via recv_event_server()
- decode the buffer handle and call bm_send_event(BM_WAIT)
- this is done in a loop for a maximum of 500 msec or until there is no more data in the event tcp connection
- maximum event size that can be received is set by ODB /Experiment/MAX_EVENT_SIZE.

This data path is the most efficient way for sending data from a remote client into midas.

Limitations:
- rpc_send_event() is not thread safe because
a) it uses a small and probably unnecessary data cache and
b) the communication protocol requires 2 syscalls to send an event (1st syscall to send 2 bytes of buffer handle, 2nd syscall to send the 
event data).
- rpc_server_receive() cannot receive arbitrary large events because recv_event_server() does not know how to allocate memory (it does 
know the event size).
 
to be continued,
K.O.
ELOG V3.1.4-2e1708b5