Back Midas Rome Roody Rootana
  Midas DAQ System  Not logged in ELOG logo
Entry  28 Dec 2018, Konstantin Olchanski, Info, note on the midas event buffer code, part 1 
    Reply  28 Dec 2018, Konstantin Olchanski, Info, note on the midas event buffer code, part 2, bm_send_event() 
       Reply  28 Dec 2018, Konstantin Olchanski, Info, note on the midas event buffer code, part 3, rpc_send_event() 
          Reply  28 Dec 2018, Konstantin Olchanski, Info, note on the midas event buffer code, part 4, reading from event buffer 
             Reply  02 Jan 2019, Konstantin Olchanski, Info, note on the midas event buffer code, part 5, bm_read_buffer() 
                Reply  02 Jan 2019, Konstantin Olchanski, Info, note on the midas event buffer code, part 6, reading events through the mserver 
                   Reply  03 Jan 2019, Konstantin Olchanski, Info, note on the midas event buffer code, part 7, event buffer polling frequencies 
                      Reply  03 Jan 2019, Konstantin Olchanski, Info, note on the midas event buffer code, part 8, writer and reader communications 
                         Reply  10 Jan 2019, Konstantin Olchanski, Info, note on the midas event buffer code, part 8, writer and reader communications 
Message ID: 1434     Entry time: 10 Jan 2019     In reply to: 1433
Author: Konstantin Olchanski 
Topic: Info 
Subject: note on the midas event buffer code, part 8, writer and reader communications 
> > > > > > > In this technical note, I write down the workings of the midas event buffer code
> Event buffer readers and writers need to communicate following information:
> 
> N.B.1. There is a fly in the ointment for the writer-to-reader path: a function called
> bm_mark_read_waiting() is called from several places to set and clear the reader "read_wait" flag.
> I think this causes several logic errors...

bm_mark_read_waiting() is removed in the new code, it is unnecessary. This uncovered a number of problems
in the writer-to-reader communications, fixed in the new code:

- bm_poll_event() did not poll anything because internal flags were not set right
- reader "read_wait" now means "I am waiting for new data, please send me a notification "B" message".
- writer sends a notification "B" message and clears "read_wait" to stop sending more notifications until the reader asks for more data.
- for remote clients, there is interplay between the 500 ms sec blank-off in sending BM_MSG notifications from the mserver and the 1000 ms timeout in the loop of bm_poll_event(). Do not 
change one of them without thinking how it will affect the other one and how they interact.

K.O.