  969   27 Feb 2014 Andreas SuterSuggestionrunlog is "ugly"
I have a couple of questions and suggestions concerning the "new" CSS style of the mhttpd, especially related to the runlog

  1. If I am not mistaken, the mhttpd.css is hard coded (path/name) into the mhttpd. Wouldn't it be beneficial to have ODB entries where to get is from? This way people could change the look and feel more freely.
  2. Especially the look and feel of the runlog is unsatisfactorily from my point of view. See . The old style was much more readable. I could recover the old style look and feel by slightly changing the mhttpd.cxx where I changed in show_rawfile(const char*) "dialogTable" to "runlogTable" in the table class. This way I could tinker around with the mhttpd.css by adding the following stuff there:
    • adding .runlogTable in line 289 :
    • adding some style information for the runlogTable :
This way the "old" runlog look and feel recovered : , which I think is much more readable.
  • If possible, I would love to have alternating background colors between the runs for readability reasons, but I am not sure how easy it would be to add something like this.
    I not much experience with HTML/CSS yet, though a concrete implementation might be different.
  •   970   27 Feb 2014 Konstantin OlchanskiSuggestionrunlog is "ugly"
    > If I am not mistaken, the mhttpd.css is hard coded (path/name) into the mhttpd.
    
    mhttpd.css is served from $MIDASSYS/resources/mhttpd.css. The actual path is reported on the mhttpd 
    "help" page.
    
    (I think the internal mhttpd.css and mhttpd.js should be removed as no longer useful - nothing will work 
    right if the real mhttpd.js and mhttpd.css cannot be served).
    
    > Especially the look and feel of the runlog is unsatisfactorily from my point of view.
    
    persons in charge of implementing the CSS stuff failed to convert quite a few pages, for example, the elog 
    and the history editor pages were left completely broken. (mostly fixed now).
    
    so thank you for reporting the runlog breakage, I hope Stefan & co can fix it quickly. (I cannot do - I have 
    have no runlog pages on any of my test experiments).
    
    > the old style was much more readable.
    
    I think the new style is not too bad, except for a few visual artefacts here and there, the general comment 
    that CSS is too complicated and hard to debug and the fact that over-subtle colouring yields inconsistent 
    visuals between different monitors and ambient lighting conditions. (persons who select the colours always 
    respond that "but to me, it looks just fine on my laptop", making it hard to resolve any issues).
    
    > I could recover the old style look and feel by slightly changing the mhttpd.cxx
    
    If you post the patches that fix it for you, I can commit them to midas. (git diff | mail olchansk@triumf.ca).
    
    K.O.
      973   28 Feb 2014 Andreas SuterSuggestionrunlog is "ugly"
    Understand me right, I mostly like the new style, except the runlog as reported.
    Attached you will find the diff's you were asking for. But as pointed out, I
    haven't worked so far on CSS and hence this should be checked!!
    
    I understand that the mhttpd.js needs to be the default one, however, mhttpd.css
    might be left to the end-user to adopt to their specific needs. I shortly
    checked in the mhttpd demon. It checks for the resources path in the ODB. If it
    also would check for a CSS name, mhttpd.css could be changed/adopted by the
    end-users without breaking things (at least it would then be their one business).
    
    > > If I am not mistaken, the mhttpd.css is hard coded (path/name) into the mhttpd.
    > 
    > mhttpd.css is served from $MIDASSYS/resources/mhttpd.css. The actual path is
    reported on the mhttpd 
    > "help" page.
    > 
    > (I think the internal mhttpd.css and mhttpd.js should be removed as no longer
    useful - nothing will work 
    > right if the real mhttpd.js and mhttpd.css cannot be served).
    > 
    > > Especially the look and feel of the runlog is unsatisfactorily from my point
    of view.
    > 
    > persons in charge of implementing the CSS stuff failed to convert quite a few
    pages, for example, the elog 
    > and the history editor pages were left completely broken. (mostly fixed now).
    > 
    > so thank you for reporting the runlog breakage, I hope Stefan & co can fix it
    quickly. (I cannot do - I have 
    > have no runlog pages on any of my test experiments).
    > 
    > > the old style was much more readable.
    > 
    > I think the new style is not too bad, except for a few visual artefacts here
    and there, the general comment 
    > that CSS is too complicated and hard to debug and the fact that over-subtle
    colouring yields inconsistent 
    > visuals between different monitors and ambient lighting conditions. (persons
    who select the colours always 
    > respond that "but to me, it looks just fine on my laptop", making it hard to
    resolve any issues).
    > 
    > > I could recover the old style look and feel by slightly changing the mhttpd.cxx
    > 
    > If you post the patches that fix it for you, I can commit them to midas. (git
    diff | mail olchansk@triumf.ca).
    > 
    > K.O.
      974   28 Feb 2014 Stefan RittSuggestionrunlog is "ugly"
     > If I am not mistaken, the mhttpd.css is hard coded (path/name) into the mhttpd.
    
    I agree that this should be removed, Unfortunately I'm away right now, so I will fix it next week. Also will put in 
    Andreas' diffs.
    
    /Stefan
      977   07 Mar 2014 Stefan RittSuggestionrunlog is "ugly"
    I put mhttpd.css and mhttpd.js into the ODB, so every experiment can change it. I put also Andreas' modifications of the CSS file for the runlog table and 
    committed the changes.
    
    /Stefan
      999   26 May 2014 Dan MelconianSuggestion"Edit-on-end" would be nice
    We use the "Edit-on-start" and it's great.  But sometimes, something breaks
    during the run, or you didn't realize you forgot to plug in a cable, or
    whatever.  It'd be nice to have an "Edit-on-end" where you could prompt the user
    to answer simple questions (like "Was this a good run?  [y/n]" or "Was the data
    polarized?  [y/n]") and/or add a quick summary of what happened that run.
    
    
    Thanks in advance,
    
    Dan
      1000   26 May 2014 Stefan RittSuggestion"Edit-on-end" would be nice
    We have similar demands, and we solve it in the following:
    
    We use a run database. In the simplest case, this can be a text file which gets written at the end of the file. The 
    mlogger has a built in SQL interface, so one can keep that table even inside a SQL interface. The per-run-
    information then contains the run number, start/stop time, number of events, some run parameters and a "junk" 
    flag. So if a run has a problem, one can set the junk flag by accessing the database (or text file) and setting this 
    flag. In many cases you see that a run had a problem not at the end of the run, but a bit later. You mayby realize 
    that the last two or three runs had the problem. With the run database approach, you can flag any run as "junk" 
    later, which we need often, An edit-on-end would not make this possible.
    
    So technically putting and edit-on-end is not a problem, but your life might be much easier if you use a run 
    database as outlined above.
    
    Best regards,
    Stefan
      1004   27 May 2014 Scott OserSuggestionSaving ODB values in a sequencer script
    I have a possibly simple feature request for the MIDAS sequencer.  It would be
    helpful to be able to save an ODB key's value to a variable, for later use, and
    would be the analogue of the ODBSET command.  I had in mind an application where
    a user wants to temporarily change some settings in the ODB, then restore the
    ODB to its original values.  Maybe something like on ODBRead command:
    
    <ODBRead path="/Path/ODBkey">varname</ODBRead>
    <ODBSet path="/Path/ODBkey">0</ODBRead> 
    <Wait for="events">3000</Wait>
    <ODBSet path="/Path/ODBkey">$varname</ODBRead> 
    
    (In which the key's value is saved to variable varname, then later written back
    to the ODB.)
    
    I'm open to other suggestions for simple ways to do this through the sequencer.
    
    Thanks! 
      1007   12 Jun 2014 Stefan RittSuggestionSaving ODB values in a sequencer script
    > I have a possibly simple feature request for the MIDAS sequencer.  It would be
    > helpful to be able to save an ODB key's value to a variable, for later use, and
    > would be the analogue of the ODBSET command.  I had in mind an application where
    > a user wants to temporarily change some settings in the ODB, then restore the
    > ODB to its original values.  Maybe something like on ODBRead command:
    
    I implemented your request, committed the changed to GIT and updated the documentation. Now you can run 
    things like:
    
    ODBSET /System/tmp/test 1234 
    ODBGET /System/tmp/test v 
    MESSAGE $v 
    
    (first you must create the key in the ODB manually).
    
    Best regards,
    Stefan
      1008   12 Jun 2014 Scott OserSuggestionSaving ODB values in a sequencer script
    Thanks, this seems very helpful, and we'll give it a try.
    
    > > I have a possibly simple feature request for the MIDAS sequencer.  It would be
    > > helpful to be able to save an ODB key's value to a variable, for later use, and
    > > would be the analogue of the ODBSET command.  I had in mind an application where
    > > a user wants to temporarily change some settings in the ODB, then restore the
    > > ODB to its original values.  Maybe something like on ODBRead command:
    > 
    > I implemented your request, committed the changed to GIT and updated the documentation. Now you can run 
    > things like:
    > 
    > ODBSET /System/tmp/test 1234 
    > ODBGET /System/tmp/test v 
    > MESSAGE $v 
    > 
    > (first you must create the key in the ODB manually).
    > 
    > Best regards,
    > Stefan
      1057   14 May 2015 Konstantin OlchanskiSuggestionchecksums for midas data files
    I am adding LZ4 and LZO compression the mlogger and as part of this work, I would like to add 
    computation of checksums for the midas files.
    
    On one side, such checksums help me confirm that uncompressed data contents is the same as original 
    data (compression/decompression is okey).
    
    On the other side, such checksums can confirm to the end user that today's contents of the midas file is 
    the same as originally written by mlogger (maybe years ago) - there was no bit rot, no file corruption, no 
    accidental or intentional modification of contents.
    
    There are several choices of checksums available:
    crc32 - as implemented by zlib (already written inside mid.gz files)
    crc32c - improved and hardware accelerated version of CRC32 (http://tools.ietf.org/html/rfc3309)
    md5 - cryptographically strong checksum, but obsolete
    sha1 - same, also obsolete
    sha256 - currently considered to be cryptographically strong
    
    Of these checksums, only sha256 (sha512, etc) are presently considered to be cryptographically strong,
    meaning that they can detect intentional file modifications. As opposed to (for example) crc32 where
    it is easy to construct 2 files with different contents but the same checksum. Both md5 and sha1 are 
    presently considered to be similarly cryptographically broken. But all of them are still usable
    as checksums - as they will detect non-intentional data modifications (bit rot, etc) with
    very high probability.
    
    (Of course the strongest checksum is also the most expensive to compute).
    
    I will probably implement crc32 (already in zlib), crc32c (easy to find hardware-accelerated
    implementations) and sha256 (cryptographically strong).
    
    I can write the computed checksums into midas.log, or into runNNN.crc32, runNNN.sha256, etc files. (or 
    both).
    
    Any thoughts on this?
    
    K.O.
      1058   14 May 2015 Stefan RittSuggestionchecksums for midas data files
    > Any thoughts on this?
    
    We use binary midas files now for ~20 years and never felt the necessity to put any checksums or even encryption on these files. The reason for that is the following: Data on 
    modern hard disks is already protected by CRC code or even ERC on the lower level, so it's very unlikely that single bytes change. If something happens, then it's a 
    corruption of the file system, so a few sectors of a file are missing or wrong. In that case a CRC won't help you much, just tells you that the files are corrupt. But you see that 
    also in the midas event structure. Each event has a header with the size of the event, so you can follow the file event by event. If something is missing, the next event header 
    is no event header but something in the middle of the date, and you recognise this immediately since the header does not make any send (date is off by many years, event ID 
    is arbitrary, event size is very different). So this redundancy in the midas event structure helps you to identify any corrupt files as good in my opinion as a CRC code will. I 
    would not want to waste a single CPU cycle on lengthy CRC or even SHA algorithms, unless I see single bytes change inside events. But in this case this can even happen at 
    the network level between frontend and backends. So we should add the CRC/SHA code at the frontend level. This could increase the dead time of the experiment which is 
    bad. And what about VME transfer? While hard disks and Ethernet networks have already built-in CRC checks, VME transfer doesn't. So how can you be sure that no bits 
    get corrupt between your ADC and your frontend computer?
    
    If people insist of having CRC or SHA protection/encryption for some reason I do not understand yet, we should make this optional, so that I can turn it off, since I don't 
    need it.
    
    /Stefan
      1059   15 May 2015 Konstantin OlchanskiSuggestionchecksums for midas data files
    > > Any thoughts on this?
    > 
    > We use binary midas files now for ~20 years and never felt the necessity to put any checksums or even encryption on these files ...
    >
    
    "I have never seen a corrupted file, therefore nobody should ever need checksums". Well,
    
    1) actually if you write mid.gz files, you get gzip checksums "for free" (but the checksums are not recorded anywhere, so 5 years later you cannot confirm that the file did not change).
    2) I had a defective computer once where reading the same file several times yielded different data. (the defect was on the motherboard, not in the disks)
    3) I am presently testing the btrfs filesystem which (like ZFS) keeps checksums for all data. For these tests I am using 3rd quality disks and I see btrfs regularly detect (and correct) "data corruption" events - where data on disk has changed.
    4) there was a report from CERN(?) where they checked the checksums on a large number of data files and found a good number of corrupted files.
    
    So bit rot does exist.
    
    In more practical terms:
    
    a) CRC32C is "free" to compute (hardware accelerated on latest CPUs), but does not detect malicious file modifications
    b) SHA256 does detect that (but for how long?), but probably too expensive to compute (speed measurement TBD).
    c) gzip compressed files have internal whole-file CRC32
    d) bzip2 compressed files have internal per-block CRC32
    e) lz4 compressed files have internal per-block xxhash checksums
    
    Personally, when dealing with compressed files, I prefer to have a checksum recoded somewhere that I can check against after I decompress the file.
    
    I think there is no need to add checksums to the MIDAS data files format itself (see c,d,e above).
    
    K.O.
      1119   28 Sep 2015 Anthony VillanoSuggestionFeature Request: MIDAS sequencer abort.
    I am working for the SuperCDMS collaboration on some DAQ issues for our upcoming
    SNOLAB installation.  So far, the MIDAS sequencer seems to be a good paradigm
    for us to do procedural tasks for our detectors and data running interspersed
    with other protocols.  
    
    In our testing we've found that the sequencer works very well for this kind of
    activity, although it would be useful to have a kind of scripted "abort" for
    when something goes wrong -- especially if the user selects to abort a run
    sequence. 
    
    Because the sequencer is setting various detector parameters to a certain value
    before performing the tasks, the values will never be restored if the user
    aborts the sequence.  Instead, perhaps there can be a portion of a MIDAS
    sequence script which is instructed to happen on an abort.  Perhaps something
    like all commands after a given tag like:
    
    ON ABORT:
    
    get run on a user-initiated abort?  
      1123   22 Oct 2015 Konstantin OlchanskiSuggestionFeature Request: MIDAS sequencer abort.
    > it would be useful to have a kind of scripted "abort" for when something goes wrong ...
    
    How about having the sequencer switching from the aborted sequence file to the special "abort" sequence file? That 
    should be simple to implement if it is not already there.
    
    K.O.
      1124   22 Oct 2015 Stefan RittSuggestionFeature Request: MIDAS sequencer abort.
    > > it would be useful to have a kind of scripted "abort" for when something goes wrong ...
    > 
    > How about having the sequencer switching from the aborted sequence file to the special "abort" sequence file? That 
    > should be simple to implement if it is not already there.
    > 
    > K.O.
    
    It's about the same effort if we jump to a specific label in a script or to a separate script. I just have to find some time to implement it.
    
    Stefan
      1125   24 Oct 2015 Stefan RittSuggestionFeature Request: MIDAS sequencer abort.
    > It would be useful to have it be specified for each script.  Reason is that it's simpler, some scripts might only 
    > change a few sensitive settings, then on abort it only has to set back to "normal" what it touched to begin with.  
    > Also, the "normal" values are usually stored in local variables, so it's important to have those similarly accessible 
    > to the "Abort" portion of the script.
    
    Agree. So I will put a special optional label, which will be accessed upon abort.
    
    Stefan
      1150   10 Dec 2015 Amy RobertsSuggestionscript command limited to 256 characters; remove limit?
    Both the /Script and /CustomScript trees in the ODB allow users to trigger a 
    script via Midas - which silently truncates command strings longer than 
    256 characters.
    
    I'd prefer that Midas place no limit on string length.  Failing that, it would be
    helpful to have character limits called out in the documentation 
    (https://midas.triumf.ca/MidasWiki/index.php//Script_ODB_tree#.3Cscript-name.3E_key_or_subtree,
    https://midas.triumf.ca/MidasWiki/index.php//Customscript_ODB_tree).
    
    As far as I can tell, odb.c allows arbitrarily large strings in the ODB data.  
    (Although key *names* are restricted to 256 characters.)  I've submitted one 
    possible version of an arbitrary-length exec_script() as a pull request 
    (https://bitbucket.org/tmidas/midas/pull-requests/).
    
    Am I misunderstanding any critical pieces?  Does Midas intentionally treat 
    strings in the ODB as limited to 256 characters?
      1152   05 Jan 2016 Tom StuttardSuggestion64 bit bank type
    I've seen that a similar question has been asked in 2011 but I'll ask again in 
    case there are any updates. Is there any way to write 64-bit data words to MIDAS 
    banks (other than breaking them up in to two 32-bit words, such as 2 DWORDs) 
    currently? And if not, is there any plan to introduce this feature in the future?
    
    Many thanks,
    Tom
      1153   05 Jan 2016 Konstantin OlchanskiSuggestion64 bit bank type
    > I've seen that a similar question has been asked in 2011 but I'll ask again in 
    > case there are any updates. Is there any way to write 64-bit data words to MIDAS 
    > banks (other than breaking them up in to two 32-bit words, such as 2 DWORDs) 
    > currently? And if not, is there any plan to introduce this feature in the future?
    
    There is no "breaking them up" as such, you can treat a midas bank as a char* array
    and store arbitrary data inside. In this sense, "there is no need" for a special 64-bit bank type.
    
    For endian-ness conversion (if such things still matter, big-endian PPC CPUs still exist), single 64-bit 
    word converts the same as two 32-bit words, so here also "there is no need", once can use banks of 
    DWORD with equal effect.
    
    The above applies equally to 64-bit integers and 64-bit double-precision IEEE-754 floating point 
    numbers.
    
    But specifically for 64-bit values, such as float64, there is a big gotcha.
    
    The MIDAS banks structure goes to great lengths to make sure each data type is correctly aligned,
    and gets it exactly wrong for 64-bit quantities - all because the bank header is three 32-bit words.
    
    bankhheader1
    bh2
    bh3
    bankdata1 <--- misaligned
    ...
    bankdataN
    bh1
    bh2
    bh3
    banddata1 <--- aligned
    ... etc
    
    So we could introduce QWORD banks today, but inside the midas file, they will be misaligned defeating 
    the only purpose of adding them.
    
    I guess the misalignement could be cured by adding dummy words, dummy banks, dummy bank 
    headers, etc.
    
    I figure this problem dates all the way bank where alignement to 16-bits was just getting important. 
    Today, in the VME word, I have to align things on 128-bit boundaries (for 2eSST 2x2 DWORD transfers).
    
    So back to your question, what advantage do you see in using a QWORD bank instead of putting the 
    same data in a DWORD bank?
    
    K.O.
    ELOG V3.1.4-2e1708b5