16
|
09 Jul 2004 |
Stefan Ritt | | Introduction of environment variable MIDASSYS |
Starting from midas version 1.9.4 on, the environment variable 'MIDASSYS'
should be defined and point to the installation directory of midas. The
purpose of that is that add-on packages (like the upcoming ROME system) can
find the midas libraries and include files. It is excatly the same as for
ROOT which defines ROOTSYS and should therefore be straight forward. The
libraries should then reside in $MIDASSYS/lib (or %MIDASSYS%\lib under windows).
To remind users about this new variable, a test has been added to odbedit,
which shows a warning when starting odbedit and MIDASSYS is not defined. |
15
|
29 Jun 2004 |
Konstantin Olchanski | | FAQ: anonymous cvs access? |
> Is the midas CVS server set-up so that I can pull the newest
> version off the CVS server?
>
> What would be my CVSROOT?
> pserver:anoncvs@midas.psi.ch:/cvs/midas *this did not work* :)
I use:
setenv CVS_RSH ssh
cvs -d cvs@midas.psi.ch:/usr/local/cvsroot checkout midas
It works most of the time. Sometimes I get locking and "permission denied"
errors on some subdirectories, presumably when CVS is being reorganized or
when there are stale locks. Does not happen too often.
K.O. |
14
|
22 Jun 2004 |
Exaos Lee | | FAQ: anonymous cvs access? |
> In the Midas doc under "Quick Start"
> http://midas.triumf.ca/doc/html/quickstart.html
> you will find the proper cvs command for accessing the latest cvs Midas
> version. The public pwd is cvs. You will only be able to checkout/update the
> package.
I cannot checkout module:
------------
01:52:16: pc2075.psi.ch: Operation timed out
01:52:16: cvs [checkout aborted]: end of file from server (consult above
messages if any)
------------
Could anybody add download tar package in the WWW interface of CVS repository.
I know the original CGI script has such a feature. Thanks. |
13
|
21 Jun 2004 |
Pierre-André Amaudruz | | FAQ: anonymous cvs access? |
> Is the midas CVS server set-up so that I can pull the newest
> version off the CVS server?
>
> What would be my CVSROOT?
> pserver:anoncvs@midas.psi.ch:/cvs/midas *this did not work* :)
>
> Piotr
>
>
In the Midas doc under "Quick Start"
http://midas.triumf.ca/doc/html/quickstart.html
you will find the proper cvs command for accessing the latest cvs Midas
version. The public pwd is cvs. You will only be able to checkout/update the
package. |
12
|
21 Jun 2004 |
Piotr Zolnierczuk | | FAQ: anonymous cvs access? |
Is the midas CVS server set-up so that I can pull the newest
version off the CVS server?
What would be my CVSROOT?
pserver:anoncvs@midas.psi.ch:/cvs/midas *this did not work* :)
Piotr
|
11
|
11 Mar 2004 |
Renee Poutissou | | Creation of secondary Midas output file. |
Jan ,
Do you need to log this stage 1 output? If not, you would use the
eventbuilder mechanism to create your stage 2 events.
I use the eventbuilder mechanism with success for my TWIST experiment.
Renee |
10
|
10 Mar 2004 |
Stefan Ritt | | Creation of secondary Midas output file. |
Dear Jan,
I had a look at your code. You create a gPhysicsEventHeader array, fill it, and expect the
framework to write it to disk. But how can the framework "guess" that you want your private
global array being written? Unfortunately it cannot do magic!
Do do what you want, you have to write a "secondary" midas file yourself. I modified your
code to do that. First, I define the event storage like
BYTE gSecEvent[ MAX_EVENT_SIZE ];
EVENT_HEADER *gPhysicsEventHeader = (EVENT_HEADER *) gSecEvent;
WORD* gPhysicsEventData = ( WORD * )( gPhysicsEventHeader + 1 );
I use gSecEvent as a BYTE array, since it only contains one avent at a time, so this is more
appropriate. Then, in the BOR routine, I open a file:
sprintf(str, "sec%05d.mid", run_number);
sec_fh = open(str, O_CREAT | O_RDWR | O_BINARY, 0644);
and close it in the EOR routine
close(sec_fh);
The event routine now manually fills events into the secondary file:
/* write event to secondary .mid file */
gPhysicsEventHeader->data_size = bk_size(gPhysicsEventData);
write(sec_fh, gPhysicsEventHeader, sizeof(EVENT_HEADER)+bk_size(gPhysicsEventData));
Note that this code is placed *inside* the for() loop over nItems, so for each detector you
create and event and write it.
That's all you need, the full file adccalib.c is attached. I tried to produce a sec01220.mid
file and was able to read it back with the mdump utility.
Best regards,
Stefan |
9
|
10 Mar 2004 |
Jan Wouters | | Creation of secondary Midas output file. |
Dear Midas Team,
I have run into a problem with Midas and was wondering if you could explain what I
am doing wrong. I have included a simple demo to illustrate what I am doing and
can send a small input data file if needed.
WHAT I AM TRYING TO DO:
Every midas event for the DANCE experiment consists of many physics events. I am
trying to create a secondary mid file where the event boundaries are now the
physics events rather than the midas events. This secondary mid file will be
analyzed using a second stage midas analyzer.
For the demo, I use the data from EV02 (one of our 15 frontends), which consists of a
variable number of fixed length structures where each structure contains the data for
one crystal from the DANCE detector.
I treat each crystal as a separate physics event and write it out in the TREK bank,
which is a demo calculated output bank, as a separate event.
(The only difference between this demo and our real system is that we would include
all the crystals from the other frontends that have approximately the same time stamp
in the output bank. Thus the output bank would consist of a varing number of
crystals in one event rather than the fixed one crystal per event used in this demo.)
THE CHANGES TO analyzer.c AND adccalib.c
I loop through the EV02 bank examining each crystal structure in turn. I calculate
"calibrated" parameters and put them into an output bank called TREK. The unusual
part of this example is that the TREK bank is no longer part of the main list of input
banks, ana_trigger_bank_list[]. Instead it is now part of a new bank list called
ana_physics_bank_list[]. See the analyzer.c file for this definition.
In adccalib.c I create the space for this new bank as follows.
EVENT_HEADER gPhysicsEventHeaders[ MAX_EVENT_SIZE / sizeof(
EVENT_HEADER ) ];
WORD* gPhysicsEventData = ( WORD * )( gPhysicsEventHeaders + 1 );
In the adc_calib routine I create the bank header as follows. Note that the serial
numbers will restart at 0 at the beginning of each midas event. Should I let the serial
number increment monotonically until the end of the run?:
gPhysicsEventHeaders->serial_number = (DWORD) - 1;
gPhysicsEventHeaders->event_id = 2;
gPhysicsEventHeaders->trigger_mask = 0;
gPhysicsEventHeaders->time_stamp = pheader->time_stamp;
In a loop that loops through all the crystals contained in EV02, I extract each crystal,
calibrate it, and store it in a TREK structure. In creating the TREK bank I assume that
each one will be a separate physics event thus I update the event serial number and
use bk_init32 to initialize the memory.
for ( short i = 0; i < nItems; i++ )
{ ++(gPhysicsEventHeaders->serial_number); // Update serial number.
bk_init32( gPhysicsEventData ); // Initialize storage.
bk_create( gPhysicsEventData, "TREK", TID_STRUCT, &trek );
trek->one = (double) pev->areahg * 1.0;
trek->two = (float) pev->timelo * 1.0;
bk_close( gPhysicsEventData, trek+1 );
pev++; // Loop to next crystal's data.
}
The output bank should consist of multiple events for each individual EV02 midas
input event.
As far as I can tell the code compiles and runs fine, but I get no data in the .mid
output file except for the ODB. I have a print statement at the beginning of each
midas event stating how many crystals were found in the EV02 bank. I also print out
the calibrated value for each crystal as it is being placed in its own TREK output
bank. The data appears correct.
I cannot place TREK in the input bank the way it normally is done in the examples
because there is not a one-to-one correspondence between a midas event and a
true physics event. Instead one midas event has many physics events. Thus the
output bank needs to be in a new memory area so that I can create a custom header
and increment the serial number properly for each event. Our follow-on analysis
using a second Midas analyzer only needs to analyze one physics event at a time
rather than one Midas event at a time, which is why we are going to all the trouble to
get this paradigm working.
I include all the code for this very simple example.
RUNNING THE CODE:
To run the example just use the run01220.mid file I will send:
./analyzer -i run01220.mid.gz -o run01220out.mid -c settings.odb_cfg -n 50
The only thing done by the settings.odb_cfg file is to turn on the TREK output bank. I
have verified that the bank is on.
SUMMARY:
I believe that I must not be creating the new TREK output bank correctly so that
midas understands that the event-by-event calculated physics data should be written
out event-by-event. I have pointed out several places in the above discussion where
I might be making a mistake.
I would like to get both this example running and a similar which create Root trees,
though the Root trees are of secondary importance. With this example I can finish
writing the second stage analyzer and get the DANCE collaboration moving forward
with their analysis. Currently, we cannot use this paradigm because I cannot create
a secondary mid file in our stage one analysis. I would be very grateful if you could
take a look at this example and tell me what I am doing incorrectly.
Jan |
8
|
17 Jan 2004 |
Stefan Ritt | | Access to hardware in the MIDAS framework |
> The result is strange because the get function is called all the time very
> fast (much faster then the 9 seconds as set in the equipment) and even
> before starting the run (I just put the flag RO_RUNNING).
This is on purpose. When the frontend is idle, it loops over the slow control
equipment as fast as possible. This way, you see changes in your hardware very
quickly. I see no reason to waste CPU cycles in the frontend when there are
better things to do like reading slow control equipment. Presume you have the
alarm system running, which turns off some equipment in case of an over
current. You better do this as quickly as possible, not wasting up to 9
seconds each time.
The 9 seconds you mention are for reading *EVENTS*. You have double
functionality: First, reading the slow control system, writing updated values
to the ODB, where someone else can display or evaluate them (in the alarm
system for example). Second, assemble events and sending them with the other
data to disk or tape. Only the second one gets controlled by RO_RUNNING and
the 9 seconds. You can see this by the updating event statists on your
frontend display, which increments only when running and then every 9 seconds. |
7
|
16 Jan 2004 |
Razvan Stefan Gornea | | Access to hardware in the MIDAS framework |
The multimeter device is indeed to simple to use MIDAS but I am just trying
it as a learning experience. The DAQ system to develop involves VME crates
and general purpose I/O boards. The slow control part, especially accessing
the I/O boards seem to me more complex then the VME access. I want to
understand very well the "correct" way of using the MIDAS slow control
framework before starting the project.
I chose the second method and created a meterdev.c driver (essentially a
copy of the nulldev.c) where I changed the init. function and the get
function. I am not sending a "INIT ..." string because for this device it
is useless. In the get function I send a "D" and read my string. I changed
the frontend of the example to have a new driver list (in the first try I
eliminated the Output device but the ODB got corrupted, I guess the class
multi needs to have defined output channels). The output channel is linked
with nulldev and null (I guess this is like if they would not be present).
The result is strange because the get function is called all the time very
fast (much faster then the 9 seconds as set in the equipment) and even
before starting the run (I just put the flag RO_RUNNING).
Thanks for any help |
6
|
14 Jan 2004 |
Stefan Ritt | | Access to hardware in the MIDAS framework |
There is some information at
http://midas.triumf.ca/doc/html/Internal.html#Slow_Control_system
and at
http://midas/download/course/course_rt03.zip , file "part1.ppt", expecially
page 59 and page 62 "writing your own device driver".
So what you are missing for your application is a "device driver" for your
multimeter. The only function it has to implement is the function CMD_INIT
where you initialize the RS232 port, and the funciton CMD_GET, which sends
a "R" and reads the value. Now you have two options:
1) You implement RS232 calls directly in your device driver
You link against rs232.c and directly call rs232_init() at the inizialization,
then call rs232_write() and rs232_read() where you read your 14 ASCII
characters.
2) You call a "bus driver" in your device driver
This method makes the device driver independent of the underlying transport
interface. So if your next multimeter accepts the same "R" command over
Ethernet, you can just replace the RS232 bus driver by the TCPIP bus driver
without having to change your device driver. But I guess that method 2) is not
worth for such a simple device like your multimeter.
So take nulldev.c or dastemp.c as your starting point, put some RS232
initialization into the init routine and the communication via "R" into
the "get" routine. The slow control frontend, driven by mfe.c, should then
regularly read your multimeter and the value should appear in the ODB. Take
the examples/slowcont/frontend.c as an example, and adjust the multi_driver[]
list to use your new device driver (instead of the nulldev).
I would like to mention that the usage of midas only makes sense for some
experiemnts which require event based readout, using VME or CAMAC crates. If
your only task is to read out some devices which are called "slow control
equipment" in the midas language, then you might be better of with labview or
something. |
5
|
14 Jan 2004 |
Razvan Stefan Gornea | | Access to hardware in the MIDAS framework |
I am just starting to explore MIDAS, i.e. reading the manual and trying
some examples. For the moment I would like to make a simple frontend that
access a portable multimeter through RS-232 port. I think this could help
me understand how to access hardare inside MIDAS framework. Initially I've
started from the MiniFE.c example and tried to initialize the serial port
on run start transition and build a readout loop in the main function. I
know that this is not a full frontend but I was just interested in getting
some experience with the drivers available in the distribution, in this
case RS-232. The portable multimeter is very simple in principle, one just
has to configure the port settings and then send character 'R' and read 14
ASCII characters from the device. Unfortunately I could not understand how
to invoke the driver services so I changed and started again with the
slowcont/frontend.c example. From this example and after reading the "Slow
Control System" section in the MIDAS manual I think that all I need to do
is to define my own equipment structure based on the multi.c class driver
with a single input channel (and replace the null driver with the RS-232).
Here I got stuck. I see from the code source that there is a relationship
between drivers at all levels (even bus) and the ODB but I don't yet fully
understand how they work. Actually for a couple of days now I am in a loop
going from class to device to bus and then back again to class drivers
trying to see how to create my own device driver and especially how to call
the bus driver. It could be that the framework is invoking the drivers and
the user just has to configure things ... up to now I didn't dare to look
at the mfe.c.
Is there a more detailed documentation about slow control and drivers then
the MIDAS manual? What is the data flow through the three layers system for
drivers? What is the role of the framework and what is left to the user
choice?
Thanks |
4
|
18 Dec 2003 |
Stefan Ritt | | Alarm on no ping? |
> I want midas alarms to go off when I cannot ping arbitrary remote hosts. Is
> there is easy/preferred way to do this? K.O.
There are "internal alarms" with type AT_EVALUATED. Just find a program
where you can put some code which gets periodically executed (like the idle
loop in the frontend), and so something like:
DWORD last = 0;
if (ss_time() > last+60)
{
last = ss_time();
/* do a ping via socket(), bind() and connect() */
...
if (status != CM_SUCCESS)
al_trigger_alarm("XYZ Ping", str, "Warning",
"Host is dead", AT_INTERNAL);
}
Pierre does the same thing in lazylogger.c, just have a look. I don't know
how to do a ping correctly in C, I guess you have to send an UDP packet
somewhere, but I never did it. If you find it out, please post it.
|
3
|
27 Aug 2003 |
Pierre-André Amaudruz | | Operation under 1.9.3 with the analyzer |
1) Prior upgrading midas to 1.9.3, make sure you've saved your ODB in ASCII
format using "odbedit> save my_odb.odb", as the internal structure is
incompatible with previous version. You will be able to restore it once
the new odb is up using "odbedit> load my_odb.odb".
2) since version 1.9.2, the analyzer supports ROOT and PAW packages.
The general Midas makefile build the analyzer core system mana.c
differently depending on presence of the environment variable $ROOTSYS.
In the case $ROOTSYS is not defined, the Makefile will create:
~/os/lib/mana.o, build for NO HBOOK calls.
~/os/lib/hmana.o, build with HBOOK calls for PAW analyzer
(requires /cern/pro/lib to be present).
In the case $ROOTSYS is defined and pointing to a valid root directory:
~/os/lib/mana.o, build for NO HBOOK calls.
~/os/lib/rmana.o, build for ROOT analyzer.
3) Since 1.9.2, the ~/examples/experiment contains the ROOT
analyzer example instead of HBOOK. The local Makefile uses the source
examples and the ~/os/lib/rmana.o for building the final user
application.
The previous HBOOK(PAW) analyzer has been moved into ~examples/hbookexpt
directory. The analyzer is build using the ~/os/lib/hmana.o
4) A new application "rmidas" is available when the system is build with
ROOT support. This application is an initial "pure" ROOT GUI implementing
TSocket for remote ROOT histogram display.
Once a ONLINE ROOT analyzer is up and running, by invoking "rmidas"
you will be prompt for a host name. Enter the node name hosting the
analyzer. You will be presented with a list of histogram which can
be display in a ROOT frame environment (see attachment).
5) The support of ROOT is also available for the logger by changing
the data format and the destination file name in the ODB structure.
This option will save on file the Midas banks converted into ROOT Tree.
This file can be opened with ROOT (see attachment).
------- ODB structure of /Logger/Channels/0/Settings
[local:midas:R]Settings>ls
Active y
Type Disk
Filename run%05d.root <<<<<<<<< new extension
Format ROOT <<<<<<<<< new format
Compression 0
ODB dump y
Log messages 0
Buffer SYSTEM
Event ID -1
Trigger mask -1
Event limit 0
Byte limit 0
Tape capacity 0
Subdir format
Current filename run00211.root
-------
. |
2
|
11 Aug 2003 |
Konstantin Olchanski | | Alarm on no ping? |
I want midas alarms to go off when I cannot ping arbitrary remote hosts. Is
there is easy/preferred way to do this? K.O. |
1
|
06 Jun 2003 |
Pierre-André Amaudruz | | Welcome |
Dear Midas users,
As you certainly aware, ELOG (Electronic Logbook) has been written
by Stefan Ritt and its functionality is part of the Midas package too.
This web site using Elog is replacing the W-Agora Forum previously setup.
You will need to register to this forum in order to gain Write access and
possible Email notification.
We would like to encourage you to post your questions or comments at
this Midas Elog site instead of using private Email to the authors as your
remarks are surely of interest to the other users too.
|