  2091   12 Feb 2021 Konstantin OlchanskiBug Reportmlogger history snafu
there is a problem with mlogger between commits xxx (17 Nov 2020) and a762bb8 (12 feb 2021). because of 
confusion between seconds and milliseconds, FILE (mhf*.dat files) and SQL history are recording with 
incorrect timestamps.

- traditional MIDAS history (*.hst files) does not have this problem (because of a buglet)
- midas-2020-12 release does not have this problem (it has mlogger from midas-2020-08 release)

there are some additional changes in mlogger that we are sorting out, when ready, we will make a new 
release of midas.

K.O.
  2090   11 Feb 2021 Isaac Labrie BoulayForumJavascript error during run transitions.
> > I am encountering a Javascript error (TypeError: client.error is undefined) when 
> > I transition between run states. Does anybody have an idea of what my problem 
> > might be? I have pasted an example of what MIDAS logs during such sequences.
> 
> 
> Not enough information. Can you do this:
> 
> a) for the javascript error, if you get it every time, open the javascript debugger 
> and capture the stack trace? or at least the file name, function name and line number 
> where the javascript exception is thrown?

I've attached a screenshot of the call stack showing the file names and line numbers.

> b) for the run start failure, start the run from odbedit "start now -v" or from 
> "mtransition -v -d 1 START" (or "stop" as the case may be). capture the output, email 
> to me directly or put in this elog here.

I have also attached a screen capture of the output.

Thanks for your help as always.

Isaac

> K.O.
> 
> 
> > 
> > Thanks for all the help!
> > 
> > Isaac
> > 
> > 
> > 09:24:08.611 2021/02/10 [mhttpd,INFO] Executing script 
> > "~/ANIS_20210106/scripts/start_daq.sh" from ODB "/Script/Start DAQ"
> > 
> > 09:24:13.833 2021/02/10 [Logger,LOG] Program Logger on host localhost started
> > 
> > 09:24:28.598 2021/02/10 [fevme,LOG] Program fevme on host localhost started
> > 
> > 09:24:33.951 2021/02/10 [mhttpd,INFO] Run #234 started
> > 
> > 09:26:30.970 2021/02/10 [mhttpd,ERROR] [midas.cxx:4260:cm_transition_call,ERROR] 
> > Client "Logger" transition 2 aborted while waiting for client "fevme": 
> > "/Runinfo/Transition in progress" was cleared
> > 
> > 09:26:31.015 2021/02/10 [mhttpd,ERROR] [midas.cxx:5120:cm_transition,ERROR] 
> > transition STOP aborted: "/Runinfo/Transition in progress" was cleared
> > 
> > 09:27:27.270 2021/02/10 [mhttpd,ERROR] 
> > [system.cxx:4937:ss_recv_net_command,ERROR] timeout receiving network command 
> > header
> > 
> > 09:27:27.270 2021/02/10 [mhttpd,ERROR] [midas.cxx:12262:rpc_client_call,ERROR] 
> > call to "fevme" on "localhost" RPC "rc_transition": timeout waiting for reply
  2089   10 Feb 2021 Konstantin OlchanskiReleasemidas-2020-12-a
midas-2020-12-a is here, see https://midas.triumf.ca/MidasWiki/index.php/Changelog#2020-12

notable change from previous midas releases:

Use of ODB "Common" by mfe.c frontends has changed. New preferred behaviour
is to have the values defined in the equipment structure in the source code
to always overwrite values in ODB /Equipment/Foo/Common, except for the value
of "Common/enabled" (equipment_common_overwrite set to TRUE).

All mfe.c frontends will need to be modified for this change:

- for old behaviour (use ODB "Common"), add: BOOL equipment_common_overwrite = false;
- for new behaviour (use equipment values in the source code), add: BOOL equipment_common_overwrite = true;

The TMFE C++ frontend does not implement this change yet, it uses all "Common" values from ODB
and there is no way to overwrite things like the MIDAS event buffer name from C++ code. This may
change with the next version.

notable updates since midas-2020-08:

- new ODB variable /Experiment/Enable sound can be used to globally prevent mhttpd from playing sounds.
- Lazylogger now supports writing data over SFTP.
- odbvalue elements on custom pages now support an onload() callback as well as onchange(). Most elements now also 
support a data-validate callback.
- custom pages can now tie a select drop-down box to an ODB value using modbselect.
- ability to choose whether the code or the current ODB values take precendence for the "Common" settings of an 
equipment when starting a frontend. See elog thread 2014 for more details, and the "Upgrade guide" below for 
instructions.
- minor improvements to mdump program - support for 64-bit data types and ability to load larger events if needed.
- minor improvements to History plots and Buffers webpage.
- bug fixes

plans for next development: major update of mlogger to simplify channel 
configuration in odb, improvements to mhttpd multithreading, new history plot 
configuration page, more c++ification.

To obtain this release, either checkout the top of branch release/midas-2020-12 
(recommended) or checkout the tag midas-2020-12-a.

K.O.
  2088   10 Feb 2021 Konstantin OlchanskiForumJavascript error during run transitions.
> I am encountering a Javascript error (TypeError: client.error is undefined) when 
> I transition between run states. Does anybody have an idea of what my problem 
> might be? I have pasted an example of what MIDAS logs during such sequences.


Not enough information. Can you do this:

a) for the javascript error, if you get it every time, open the javascript debugger 
and capture the stack trace? or at least the file name, function name and line number 
where the javascript exception is thrown?

b) for the run start failure, start the run from odbedit "start now -v" or from 
"mtransition -v -d 1 START" (or "stop" as the case may be). capture the output, email 
to me directly or put in this elog here.

K.O.


> 
> Thanks for all the help!
> 
> Isaac
> 
> 
> 09:24:08.611 2021/02/10 [mhttpd,INFO] Executing script 
> "~/ANIS_20210106/scripts/start_daq.sh" from ODB "/Script/Start DAQ"
> 
> 09:24:13.833 2021/02/10 [Logger,LOG] Program Logger on host localhost started
> 
> 09:24:28.598 2021/02/10 [fevme,LOG] Program fevme on host localhost started
> 
> 09:24:33.951 2021/02/10 [mhttpd,INFO] Run #234 started
> 
> 09:26:30.970 2021/02/10 [mhttpd,ERROR] [midas.cxx:4260:cm_transition_call,ERROR] 
> Client "Logger" transition 2 aborted while waiting for client "fevme": 
> "/Runinfo/Transition in progress" was cleared
> 
> 09:26:31.015 2021/02/10 [mhttpd,ERROR] [midas.cxx:5120:cm_transition,ERROR] 
> transition STOP aborted: "/Runinfo/Transition in progress" was cleared
> 
> 09:27:27.270 2021/02/10 [mhttpd,ERROR] 
> [system.cxx:4937:ss_recv_net_command,ERROR] timeout receiving network command 
> header
> 
> 09:27:27.270 2021/02/10 [mhttpd,ERROR] [midas.cxx:12262:rpc_client_call,ERROR] 
> call to "fevme" on "localhost" RPC "rc_transition": timeout waiting for reply
  2087   10 Feb 2021 Isaac Labrie BoulayForumJavascript error during run transitions.
Hi all,

I am encountering a Javascript error (TypeError: client.error is undefined) when 
I transition between run states. Does anybody have an idea of what my problem 
might be? I have pasted an example of what MIDAS logs during such sequences.

Thanks for all the help!

Isaac


09:24:08.611 2021/02/10 [mhttpd,INFO] Executing script 
"~/ANIS_20210106/scripts/start_daq.sh" from ODB "/Script/Start DAQ"

09:24:13.833 2021/02/10 [Logger,LOG] Program Logger on host localhost started

09:24:28.598 2021/02/10 [fevme,LOG] Program fevme on host localhost started

09:24:33.951 2021/02/10 [mhttpd,INFO] Run #234 started

09:26:30.970 2021/02/10 [mhttpd,ERROR] [midas.cxx:4260:cm_transition_call,ERROR] 
Client "Logger" transition 2 aborted while waiting for client "fevme": 
"/Runinfo/Transition in progress" was cleared

09:26:31.015 2021/02/10 [mhttpd,ERROR] [midas.cxx:5120:cm_transition,ERROR] 
transition STOP aborted: "/Runinfo/Transition in progress" was cleared

09:27:27.270 2021/02/10 [mhttpd,ERROR] 
[system.cxx:4937:ss_recv_net_command,ERROR] timeout receiving network command 
header

09:27:27.270 2021/02/10 [mhttpd,ERROR] [midas.cxx:12262:rpc_client_call,ERROR] 
call to "fevme" on "localhost" RPC "rc_transition": timeout waiting for reply
  2086   08 Feb 2021 Stefan RittSuggestionmhttpd browser caching
> It seems that the only reliable way to bypass the browser cache is to add
> a tag with a random number to the URL ("&ts=currenttime").

Indeed that's the only reliable way to avoid caching across browsers. An alternative is

("&r=" + Math.random())

to add a random number.


> BTW, things like midas.js are also cached, and it is common to see problems
> after updating midas, where status.html is newly loaded, but midas.js is an old
> stale version from cache.

Reloading JavaScript file NOT from the cache is really tricky these days. I added a
special Google Chrome extension to clear my browser cache, which works reliably:

https://chrome.google.com/webstore/detail/clear-cache/cppjkneekbjaeellbfkmgnhonkkjfpdn

Stefan
  2085   08 Feb 2021 Konstantin OlchanskiSuggestionmhttpd browser caching
>    r->rsprintf("Expires: %s\r\n", str);

The best I can tell, none of this works in current browsers. with google-chrome,
I see it cache pretty much everything regardless of "expires", "no cache", etc
and anything else I tried.

Things like shift-<reload>, etc used to work to refresh the cache, but not any more.

So, I too, see confusing side-effects of caching, where I change something in ODB,
but "nothing happens". Then I scratch my head for 30 minutes until I remember
to open the javascript debugger where shift-<reload> (or is it ctrl-<reload>) actually works.

It seems that the only reliable way to bypass the browser cache is to add
a tag with a random number to the URL ("&ts=currenttime").

This is for HTTP GET requests. HTTP POST does not seem to be cached, so I do not worry
about this nonsense for json-rpc requests.

Perhaps we should do this random number trick for all user actions. User can
press buttons only so fast, we should be able to sustain the rate. Anything
loaded automatically or from a timer, we should allow caching.

BTW, things like midas.js are also cached, and it is common to see problems
after updating midas, where status.html is newly loaded, but midas.js is an old
stale version from cache.

Messy.

K.O.
  2084   08 Feb 2021 Konstantin OlchanskiForumpoll_event() is very slow.
> I should mention that I was using midas/examples/Triumf/c++/fevme.cxx

this is correct, the fevme frontend is written to do 100% CPU-busy polling.

there is several reasons for this:
- on our VME processors, we have 2 core CPUs, 1st core can poll the VME bus, 2nd core can run 
mfe.c and the ethernet transmitter.
- interrupts are expensive to use (in latency and in cpu use) because kernel handler has to call 
use handler, return back etc
- sub-millisecond sleep used to be expensive and unreliable (on 1-2GHz "core 1" and "core 2" 
CPUs running SL6 and SL7 era linux). As I understand, current linux and current 3+GHz CPUs can 
do reliable microsecond sleep.

K.O.
  2081   25 Jan 2021 Thomas LindnerSuggestionmhttpd browser caching
I tried reloading the pages.  If I reloaded the actual elog page 

https://server.triumf.ca/?cmd=Elog

then it bypassed the cache and got the correct updated page from mhttpd.

However, if when I reloaded the status page

https://server.triumf.ca/?cmd=Status

and then clicked the Elog button then I just got the cached (old) page.  Admittedly reloading the status page doesn't make so much sense (once I thought about it), but it is what I tried first (I'm good at modelling unexpected user behaviour); so there is some risk that the user will try reloading the wrong page and will be stuck not getting the external elog page (until 24 hours runs out).

Anyway, I will update the documentation to note that you need to reload the elog page after changing this variable.  That's probably an adequate solution.

I certainly don't suggest getting rid of caching entirely.  I was trying to think whether there was a set of pages where it would make sense to disable the cache (like the elog page).  But maybe that will just cause more problems.


> Let me first explain a bit why caching is there. Once we had the case that someone from 
> TRIUMF opened a midas custom page at T2K. It took about one minute (!) to load the page. 
> 
> When we looked at it, we found that the custom page pulled about 100 items with individual
> HTTP requests from Japan, each taking about one second for the roundtrip. Then we redesigned
> the custom page communication so that many ODB entries could be retrieved in one operation,
> which improved the loading time from 100s to about 2s.
> 
> With the buttons we will have to make the same compromise. If we do not cache anything,
> loading the midas status page over the Pacific takes many seconds. If we cache all, any
> change on the midas side will not be reflected on the web page. So there is a compromise
> to be made. I thought I designed it such that the side menu is cached locally, but when
> the user presses "reload", then the full menu is fetched from the server. Of course one
> has to remember this, so changing the ELOG URL or other things on the menu require a
> reload (or wait a certain time for the cache to expire). So try again if that's working
> for you. If not, I can visit it again and check if there is any bug.
> 
> If we go the route to disable the cache, better try this to T2K and see what you get before
> we commit ourselves to that. Last time TRIUMF people were complaining a lot about long
> load times.
> 
> Best,
> Stefan
  2080   25 Jan 2021 Stefan RittSuggestionmhttpd browser caching
Let me first explain a bit why caching is there. Once we had the case that someone from 
TRIUMF opened a midas custom page at T2K. It took about one minute (!) to load the page. 

When we looked at it, we found that the custom page pulled about 100 items with individual
HTTP requests from Japan, each taking about one second for the roundtrip. Then we redesigned
the custom page communication so that many ODB entries could be retrieved in one operation,
which improved the loading time from 100s to about 2s.

With the buttons we will have to make the same compromise. If we do not cache anything,
loading the midas status page over the Pacific takes many seconds. If we cache all, any
change on the midas side will not be reflected on the web page. So there is a compromise
to be made. I thought I designed it such that the side menu is cached locally, but when
the user presses "reload", then the full menu is fetched from the server. Of course one
has to remember this, so changing the ELOG URL or other things on the menu require a
reload (or wait a certain time for the cache to expire). So try again if that's working
for you. If not, I can visit it again and check if there is any bug.

If we go the route to disable the cache, better try this to T2K and see what you get before
we commit ourselves to that. Last time TRIUMF people were complaining a lot about long
load times.

Best,
Stefan
  2079   25 Jan 2021 Thomas LindnerSuggestionmhttpd browser caching
I have a more subtle point about the new ODB key for using an external elog I mentioned in [1].  I was very confused after changing the ODB "External Elog" because mhttpd still wasn't using my external elog URL.  I started trying to debug mhttpd.cxx, but found a lot of bits of mhttpd didn't seem to be getting called.  I eventually realized that my browser had been caching the responses for some (though not all) of the MIDAS navigation buttons.  Clearing my browser cache fixed the problem and allowed me to use the MIDAS button to the external ELOG.  This caching happens on my macbook for both Firefox 84.0.2 and Safari 13.1.

Many of the requests to mhttpd end up going to send_fp(), where we explicitly set the cache time to 24 hours.

   // send HTTP cache control headers                                                                                               
   time_t now = time(NULL);
   now += (int) (3600 * 24);
   struct tm* gmt = gmtime(&now);
   const char* format = "%A, %d-%b-%y %H:%M:%S GMT";
   char str[256];
   strftime(str, sizeof(str), format, gmt);
   r->rsprintf("Expires: %s\r\n", str);

Some other MIDAS buttons don't seem to be cached by the browser; for instance the response for the 'OldHistory' button doesn't get cached.

Should we remove the cache instruction for at least some of the buttons?  At least for the elog button where we want the link direction to get switched by an ODB key the caching seems a bad idea.

[1] https://midas.triumf.ca/elog/Midas/2078
  2078   21 Jan 2021 Thomas LindnerInfoUsing external ELOG with newer mhttpd
A warning, in case others have the same problem I had.

In the past you could configure mhttpd so that the 'Elog' button would redirect to an external ELOG server; to do this you only needed to create and set the ODB variable '/Elog/URL' to the URL of your external ELOG server.

But with the newer MIDAS you need to set two ODB variables:

* "/Elog/URL" needs to be set to the URL of the external ELOG.
* "/Elog/External Elog" needs to be set to 'y'

I hadn't noticed this and was confused why my Elog button wasn't working after upgrading MIDAS.

MIDAS documentation was updated to reflect this change:

https://midas.triumf.ca/MidasWiki/index.php/Electronic_Logbook_(ELOG)
  2077   15 Jan 2021 Isaac Labrie BoulayForumpoll_event() is very slow.
> > 
> > I'm currently trying to see if I can speed up polling in a frontend I'm testing. 
> > Currently it seems like I can't get 'lam's to happen faster than 120 times/second. 
> > There must be a way to make this faster. From what I understand, changing the poll 
> > time (500ms by default) won't affect the frequency of polling just the 'lam' 
> > period.
> > 
> > Any suggestions?
> > 
> 
> You could switch from the traditional midas mfe.c frontend to the C++ TMFE frontend,
> where all this "lam" and "poll" business is removed.
> 
> At the moment, there are two example programs using the C++ TMFE frontend,
> single threaded (progs/fetest_tmfe.cxx) and multithreaed (progs/fetest_tmfe_thread.cxx).
> 
> K.O.

Ok. I did not know that there was a C++ OOD frontend example in MIDAS. I'll take a look at 
it. Is there any documentation on it works?

Thanks for the support!

Isaac
  2076   14 Jan 2021 Isaac Labrie BoulayForumpoll_event() is very slow.
> Something must be wrong on your side. If you take the example frontend under
> 
> midas/examples/experiment/frontend.cxx
> 
> and let it run to produce dummy events, you get about 90 Hz. This is because we have a
> 
>   ss_sleep(10);
> 
> in the read_trigger_event() routine to throttle things down. If you remove that sleep, 
> you get an event rate of about 500'000 Hz. So the framework is really quick.
> 
> Probably your routine which looks for a 'lam' takes really long and should be fixed.
> 
> Stefan

Hi Stefan,

I should mention that I was using midas/examples/Triumf/c++/fevme.cxx. I was trying to see 
the max speed so I had the 'lam' always = 1 with nothing else to add overhead in the 
poll_event(). I was getting <200 Hz. I am assuming that this is a bug. There is no 
ss_sleep() in that function.

Thanks for your quick response!

Isaac
  2075   14 Jan 2021 Pintaudi GiorgioForumpoll_event() is very slow.
> Something must be wrong on your side. If you take the example frontend under
> 
> midas/examples/experiment/frontend.cxx
> 
> and let it run to produce dummy events, you get about 90 Hz. This is because we have a
> 
>   ss_sleep(10);
> 
> in the read_trigger_event() routine to throttle things down. If you remove that sleep, 
> you get an event rate of about 500'000 Hz. So the framework is really quick.
> 
> Probably your routine which looks for a 'lam' takes really long and should be fixed.
> 
> Stefan

Sorry if I am going off-topic but, because the ss_sleep function was mentioned here, I 
would like to take the chance and report an issue that I am having.

In all my slow control frontends, the CPU usage for each frontend is close to 100%. This 
means that each frontend is monopolizing a single core. When I did some profiling, I 
noticed that 99% of the time is spent inside the ss_sleep function. Now, I would expect 
that the ss_sleep function should not require any CPU usage at all or very little.

So my two questions are:
Is this a bug or a feature?
Would you able to check/reproduce this behavior or do you need additional info from my 
side?
  2074   13 Jan 2021 Stefan RittForumpoll_event() is very slow.
Something must be wrong on your side. If you take the example frontend under

midas/examples/experiment/frontend.cxx

and let it run to produce dummy events, you get about 90 Hz. This is because we have a

  ss_sleep(10);

in the read_trigger_event() routine to throttle things down. If you remove that sleep, 
you get an event rate of about 500'000 Hz. So the framework is really quick.

Probably your routine which looks for a 'lam' takes really long and should be fixed.

Stefan
  Draft   13 Jan 2021 Pierre-Andre AmaudruzForumpoll_event() is very slow.
> Hi all,
> 
> I'm currently trying to see if I can speed up polling in a frontend I'm testing. 
> Currently it seems like I can't get 'lam's to happen faster than 120 times/second. 
> There must be a way to make this faster. From what I understand, changing the poll 
> time (500ms by default) won't affect the frequency of polling just the 'lam' 
> period.
> 
> Any suggestions?
> 
> Thanks for your help!
> 
> Isaac

Hi,

How many equipment do you have and of what type?
What is the measured readout time of your equipment?

As you mentioned the polling time define the maximum time you spend in the in polling call before checking other equipment and system activities. But as soon as you get a LAM during the polling loop, the event is readout. The readout time of this equipment is obviously to be considered as well.

In case you have multiple equipment, the readout time of the other equipment is to be taken in account as you wont return to your polling prior the completion of them.
  2072   13 Jan 2021 Konstantin OlchanskiForumpoll_event() is very slow.
> 
> I'm currently trying to see if I can speed up polling in a frontend I'm testing. 
> Currently it seems like I can't get 'lam's to happen faster than 120 times/second. 
> There must be a way to make this faster. From what I understand, changing the poll 
> time (500ms by default) won't affect the frequency of polling just the 'lam' 
> period.
> 
> Any suggestions?
> 

You could switch from the traditional midas mfe.c frontend to the C++ TMFE frontend,
where all this "lam" and "poll" business is removed.

At the moment, there are two example programs using the C++ TMFE frontend,
single threaded (progs/fetest_tmfe.cxx) and multithreaed (progs/fetest_tmfe_thread.cxx).

K.O.
  2071   13 Jan 2021 Isaac Labrie BoulayForumpoll_event() is very slow.
Hi all,

I'm currently trying to see if I can speed up polling in a frontend I'm testing. 
Currently it seems like I can't get 'lam's to happen faster than 120 times/second. 
There must be a way to make this faster. From what I understand, changing the poll 
time (500ms by default) won't affect the frequency of polling just the 'lam' 
period.

Any suggestions?

Thanks for your help!

Isaac

Hi,

What is the actual readout time, event size?
Do you have multiple equipment and of what type if any?

PAA
  2070   08 Jan 2021 Stefan RittForumhistory and variables confusion
We kind of agreed to rewrite the slow control system in C++. Each device will have its own driver derived from a common base class implementing the general communication. The reason we need a "system" and not only a "hand-written" driver is because we want:

- glue many device drivers together for a single equipment
- have a dedicated readout thread for every device, in order not to block other devices
- have a common error reporting scheme working with several threads
- being able to disable/enable individual devices without changing the history system each time
- having a common naming scheme for all devices (like "enforce" /Equipment/<name>/Settings/Names xxx) which is needed by the history system
- ...

Will see when we have time for that.

Stefan