  1305   13 Jul 2017 Konstantin OlchanskiInfoimplemented: json-rpc batch requests
The mhttpd json-rpc interface now implements batch requests per
http://www.jsonrpc.org/specification#batch

In the nutshell, instead of a single request, one can send a json array of requests and receive a json 
array of replies.

As a variance from the spec, the midas implementation executes the requests strictly in-order and 
the array of replies corresponds exactly to the array of requests (the spec requires user to use the 
"id" field to match replies to requests, in midas json-rpc, the 1st reply is always to the 1st request,
2nd reply is to the 2nd request and so forth).

See this in action look at resources/example.html and in resources/transition.html

K.O.
  1680   08 Sep 2019 Vinzenz BildsteinBug Reporthttps redirect and ODB access
I'm not sure if these issues are related or not, but I'm getting an error
message when I want to access the root of the ODB via the webserver:
[mhttpd,ERROR] [mhttpd.cxx:563:rread,ERROR] Cannot read file '/root', read of
4096 returned -1, errno 21 (Is a directory)

I also tried turning the re-direct from http to https off, but this does not
seem to work. I also noticed that the redirect changes the localhost into a
hostname. Where does mongoose take this hostname from?

EDIT: Seems that the change of the hostname is due to a setting in /etc/hosts,
i.e. all my fault ...

EDIT: I think there was some issue with the mhttpd. When I checked the output (I
used screen to run it), it was full of these messages:

ss_semaphore_wait_for: semop/semtimedop(2588679) returned -1, errno 43
(Identifier removed)
al_check: Something is wrong with our semaphore, ss_semaphore_wait_for()
returned 408, aborting.
al_check: Cannot abort - this will lock you out of odb. From this point, MIDAS
will not work correctly. Please read the discussion at
https://midas.triumf.ca/elog/Midas/945

Restarted it and it stopped redirecting. So accessing the root of the ODB via
the webserver is the only issue now.
  1686   16 Sep 2019 Konstantin OlchanskiBug Reporthttps redirect and ODB access
> I'm not sure if these issues are related or not, but I'm getting an error
> message when I want to access the root of the ODB via the webserver:
> [mhttpd,ERROR] [mhttpd.cxx:563:rread,ERROR] Cannot read file '/root', read of
> 4096 returned -1, errno 21 (Is a directory)

This is an old bug. It was part of the "custom path" confusion. Fixed (I think) in all midas-2019 
releases.

To confirm, which version are you using (run "odbedit ver" or look on the mhttpd "help" page)?

If you have an older version, I recommend that you update to midas-2019-03 (cd midas; git pull; 
git checkout midas-2019-03; make clean; make).

If you feel adventurous, you can also update to the head of the development version
and see all the new features (cmake, c++11, new history pages).

If you do not feel adventurous, wait until we have midas-2019-09 ready, use midas-2019-03 
until then.

K.O.
  851   04 Jan 2013 Nabin PoudyalSuggestionhow to start using midas
Please, tell me how to choose a value of a "key" like DCM, pulser period,
presamples, upper thresholds to run a experiment? where can I find the related
informations? 
  401   20 Aug 2007 Konstantin OlchanskiBug Reporthow to handle end of run?
I am having problems with handling the end-of-run situation in my midas
frontend. I have a device that continuously sends data (over USB) and I read
this data in my "read_event" function.

Everything is good until the end-of-run, at which time this happens:
0) mfe.c calls my read_event() to read the data (loop until the end-of-run
transition)
1) mfe.c calls my end_of_run()
2) here, I tell the device "please stop sending data"
3) all seems good, but wait!!!
4) there is all this data generated between step 0 and step 2 still sitting
inside the device and it has nowhere to go: the run is ended, the output file is
closed, my read_event() will never be called ever again (well, until the next run).

It seems to me mfe.c needs to have one more function, something like
"pre_end_of_run()" that works like this:
0) mfe.c calls my read_event() to read the data (loop until the end-of-run
transition)
1) mfe.c calls pre_end_of_run(), here I tell the device to stop sending data
2) mfe.c calls read_event() for the very last time, to give me the opportunity
to read and send away any data I still may have.
3) mfe.c calls the end_of_run(). The run is truely finished.

Any thoughts?

K.O.
  405   03 Sep 2007 Stefan RittBug Reporthow to handle end of run?
> I am having problems with handling the end-of-run situation in my midas
> frontend. I have a device that continuously sends data (over USB) and I read
> this data in my "read_event" function.
> 
> Everything is good until the end-of-run, at which time this happens:
> 0) mfe.c calls my read_event() to read the data (loop until the end-of-run
> transition)
> 1) mfe.c calls my end_of_run()
> 2) here, I tell the device "please stop sending data"
> 3) all seems good, but wait!!!
> 4) there is all this data generated between step 0 and step 2 still sitting
> inside the device and it has nowhere to go: the run is ended, the output file is
> closed, my read_event() will never be called ever again (well, until the next run).
> 
> It seems to me mfe.c needs to have one more function, something like
> "pre_end_of_run()" that works like this:
> 0) mfe.c calls my read_event() to read the data (loop until the end-of-run
> transition)
> 1) mfe.c calls pre_end_of_run(), here I tell the device to stop sending data
> 2) mfe.c calls read_event() for the very last time, to give me the opportunity
> to read and send away any data I still may have.
> 3) mfe.c calls the end_of_run(). The run is truely finished.
> 
> Any thoughts?

You can achieve the desired functionality without changing mfe.c:

0) mfe.c calls read_event
1) mfe.c calls end_of_run. Your end_of_run tells the device to stop data and flushes
the remaining data. At this point you have to re-make actually a part of the mfe.c
functionality, but basically you need a bm_compose_event() and a bm_send_event(), so
just a few lines of code. If you want to have the final event number right in your
equipment, you also need to update eq->events_sent accordingly. 

Given the fact that 99% of the experiments do not need this functionality, I propose
that we keep mfe.c and you add the few lines of code into your user part of the
specific frontend.

Stefan
  2646   09 Dec 2023 Pavel MuratForumhow to fix forgotten password ?
[Dear All, I apologize in advance for spamming.]

1) I tried to login into the forum from the lab computer and realized 
   that I forgot my password
2) I tried to reset the password and found that when registering 
   I mistyped my email address, having typed '.giv' instead of '.gov'
   in the domain name, so the recovery email went into nowhere 

(still have one session open on the laptop so can post this question)

- how do I get my email address fixed so I'd be able to reset the password?

-- many thanks, Pasha
  498   29 Aug 2008 Konstantin OlchanskiInfohistory_odbc: store MIDAS history in ODBC/MySQL database
The code for storing midas history in an odbc sql database has been committed.
Changes:
include/history_odbc.h, src/history_odbc.cxx --- implementation
src/mlogger.c --- call the history_odbc functions
utils/mh2sql.cxx --- import existing midas history files (*.hst) into an odbc
sql database.

This new code is enabled by the HAVE_ODBC gunk in the Makefile. If compilation
bombs, please let me know and as a work around, comment out all instances of
HAVE_ODBC from your Makefile.

Limitations:
- mhttpd support for reading history data from odbc sql database is missing
- many sql functions are implemented in a very minimalistic form (i.e. when
defining a history event, we blindly ask sql to create the tables, even if they
already exist - this works, but spams the midas log with sql errors).
- error handling is incomplete: after any sql error, the odbc connection is closed.
- only MySQL (and ascii output) are supported: we use mysql-specific data types
as they match midas types exactly. Code to support PgSQL is present and it used
to work, but is commented out. (At TRIUMF/T2K, we intend to use MySQL exclusively).
- ODBC ascii interface is used, instead of the potentially more efficient binary
interface.

To enable:
- create a MySQL database,
- create $HOME/.odbc.ini (see attached example)
- set ODB "/History/PerVariableHistory" to "1" - the new code is intended to be
used with per-variable history. Per-equipment (traditional) history would work,
but will result in suboptimal layout of SQL tables.
- set ODB "/Logger/ODBC_DSN" to the DSN defined in .odc.ini.
- set ODB "/Logger/ODBC_Debug" to non-zero to enable debugging output from the
new code.

To use the "ascii output" mode:
Included is code to write "ascii" sql output into a text file, instead of using
an actual SQL database. To enable it, set "ODBC_DSN" to
"/path/to/some/text/file" and all SQL output will be written to this file. No
actual SQL database required. This mode exists mostly for debugging the SQL syntax.

Despite limitations, the committed code is fully functional - we are presently
using it to record history data from slow controls of T2K detector tests
(voltages, currents, temperatures).

Comments and suggestions on naming and mapping from odb structures to SQL tables
is very much welcome.

K.O.
  2096   24 Feb 2021 Zaher SalmanBug Reporthistory reload
I have a history that is embedded in a custom page using

<div class="mjshistory" data-group="SampleCryo" data-panel="SampleTemp" data-scale="30m" style="'+size+' position: relative;left: 640px;top: -205px;"></div>

this works fine when I load the page but seems to cause a timeout when reloading (F5) the page. It used to work fine last year but since a midas update this year it does not work. 

When I manually stop the script when firefox reports that it is slowing down the browse I get the following in the console:

Script terminated by timeout at:
binarySearch@http://xxx.psi.ch:8081/mhistory.js:1051:11
MhistoryGraph.prototype.findMinMax@http://xxx.psi.ch:8081/mhistory.js:1583:28
MhistoryGraph.prototype.loadInitialData/<@http://xxx.psi.ch:8081/mhistory.js:780:15

any ideas what may be causing this?

thanks.

Another hint to the problem, the custom page is accessible via 
http://xxx.psi.ch:8081/?cmd=custom&page=SampleCryo&
once loaded the address changes to where A and B change values as time passes (I guess B-A=30m).
http://xxx.psi.ch:8081/?cmd=custom&page=SampleCryo&&A=1614173369&B=1614175169
  2097   25 Feb 2021 Stefan RittBug Reporthistory reload
I have to reproduce the problem. Can you please send me the full link by direct email. As you know, I'm also at PSI.

Stefan
  2647   09 Dec 2023 Pavel MuratForumhistory plotting: where to convert the ADC readings into temps/voltages?
to plot time dependencies of the monitored detector parameters, say, voltages or temperatures,
one needs to convert the coresponging ADC readings into floats.

One could think of two ways of doing that: 

- one can perform the ADC-->T or ADC-->V conversion in the MIDAS frontend, 
  store their [float] values in the data bank, and plot precalculated parameters vs time

- one can also store in the data bank the ADC readings which typically are short's 
  and convert them into floats (V's or T's) at the plotting time 

The first approach doubles the storage space requirements, and I couldn't find the place where 
one would do the conversion, if stored were the 16-bit ADC readings.

I'm sure this issue has been thought about, so what is the "recommended MIDAS way" of performing 
the ADC -> monitored_number conversion when making MIDAS history plots ?

-- many thanks, regards, Pasha
  2650   10 Dec 2023 Stefan RittForumhistory plotting: where to convert the ADC readings into temps/voltages?
> to plot time dependencies of the monitored detector parameters, say, voltages or temperatures,
> one needs to convert the coresponging ADC readings into floats.
> 
> One could think of two ways of doing that: 
> 
> - one can perform the ADC-->T or ADC-->V conversion in the MIDAS frontend, 
>   store their [float] values in the data bank, and plot precalculated parameters vs time
> 
> - one can also store in the data bank the ADC readings which typically are short's 
>   and convert them into floats (V's or T's) at the plotting time 
> 
> The first approach doubles the storage space requirements, and I couldn't find the place where 
> one would do the conversion, if stored were the 16-bit ADC readings.
> 
> I'm sure this issue has been thought about, so what is the "recommended MIDAS way" of performing 
> the ADC -> monitored_number conversion when making MIDAS history plots ?

Most experiment go with the second method. The front-end program converts all ADC reading into physicsl 
units, i.e. not only Volt, but even Degrees Centigrade or Tesla or whatever. The slow control part of 
midas then puts these number into /Equipment/<name>/Variables as "float", and the history system picks 
them up from there. This way your history is shown in physical units and not ADC count. Actually the 
recommended slow control framework (check the examples direcotory) does not rely on data banks, but 
puts values directly into the ODB. This is typically done faster, like once per second if a value 
changes, rather than slow control events which are generated maybe once per 10 seconds or once per 
minute. Usually the slow control values are only few compared with trigger data, so a factor of two 
there does not really matter. In the MEG experiment, we have like 400 GB of slow control data per year, 
but 400 TB of trigger data per year.

Best,
Stefan
  2049   09 Dec 2020 Frederik WautersForumhistory and variables confusion
I have a fe, with 2 "equipments" (2 different types of LV supplies).

Equipment/../Setting has a "Names" key, with the actual channel names (ch1, ch2, ...) of the devices.

Equipment/../Variables has channel states, voltage, etc. 

I also write a separate midas bank for each supply.

When I turn the "Log History" on, 2 things happen which cause troubles:
1. It writes the data of both bank to both the /Equipment/(Device1/Device2)/Variables .
2. I have e.g. 4 channels. In the banks I write current and voltages, so 8 numbers. When I turn on the logger I get an "Array size mismatch" between names and the midas bank size.

The only way around this is to disable the history logging in the equipment, and set "virtual" History events?
  2050   09 Dec 2020 Stefan RittForumhistory and variables confusion
First, the writing of banks is completely independent of the history system. Banks go to the log file only, 
while the history is only linked to the "Variables" section in the ODB.

Second, it's advisable to group similar equipment into one. Like if you have five power supplies powering
and experiment, you don't want to have five equipments Supply1, Supply2, ..., but only one equipment
"Power Supplies". In the frontend belonging to that equipment, you define a DEVICE_DRIVER list with
one entry for each power supply. If you interact with an mscb device, there are some helper functions
which simplify the definition of the equipment and which I can send you privately. So your device
driver looks a bit like the one attached.

If you cannot do that and absolutely want separate equipments, please post a complete ODB subtree of your
settings, and I can try to reproduce your problem.

Stefan

======================

DEVICE_DRIVER power_driver[] = {
   {"Power Supply 1", mscbdev, 0, NULL, DF_INPUT | DF_MULTITHREAD},
   {"Power Supply 2", mscbdev, 0, NULL, DF_INPUT | DF_MULTITHREAD},
   {"Power Supply 3", mscbdev, 0, NULL, DF_INPUT | DF_MULTITHREAD},
   {""}
};

...

INT frontend_init()
{
   mscb_define("mscbxxx.psi.ch", "Power Supplies", "Power Supply 1", power_driver, 1, 0, "Output 1", 0.1);
   mscb_define("mscbxxx.psi.ch", "Power Supplies", "Power Supply 1", power_driver, 1, 1, "Output 2", 0.1);
   ...
}

/*-- Function to define MSCB variables in a convenient way ---------*/

void mscb_define(const char *submaster, const char *equipment, const char *devname, 
                 DEVICE_DRIVER *driver, int address, unsigned char var_index, 
                 const char *name, double threshold)
{
   int i, dev_index, chn_index, chn_total;
   char str[256];
   float f_threshold;
   HNDLE hDB;

   cm_get_experiment_database(&hDB, NULL);

   if (submaster && submaster[0]) {
      sprintf(str, "/Equipment/%s/Settings/Devices/%s/Device", equipment, devname);
      db_set_value(hDB, 0, str, submaster, 32, 1, TID_STRING);
      sprintf(str, "/Equipment/%s/Settings/Devices/%s/Pwd", equipment, devname);
      db_set_value(hDB, 0, str, "meg", 32, 1, TID_STRING);
   }

   /* find device in device driver */
   for (dev_index=0 ; driver[dev_index].name[0] ; dev_index++)
      if (equal_ustring(driver[dev_index].name, devname))
         break;

   if (!driver[dev_index].name[0]) {
      cm_msg(MERROR, "mscb_define", "Device \"%s\" not present in device driver list", devname);
      return;
   }

   /* count total number of channels */
   for (i=chn_total=0 ; i<=dev_index ; i++)
      if (((driver[dev_index].flags & DF_INPUT) > 0 && (driver[i].flags & DF_INPUT)) ||
          ((driver[dev_index].flags & DF_OUTPUT) > 0 && (driver[i].flags & DF_OUTPUT)))
      chn_total += driver[i].channels;

   chn_index = driver[dev_index].channels;
   sprintf(str, "/Equipment/%s/Settings/Devices/%s/MSCB Address", equipment, devname);
   db_set_value_index(hDB, 0, str, &address, sizeof(int), chn_index, TID_INT, TRUE);
   sprintf(str, "/Equipment/%s/Settings/Devices/%s/MSCB Index", equipment, devname);
   db_set_value_index(hDB, 0, str, &var_index, sizeof(char), chn_index, TID_BYTE, TRUE);

   if (threshold != -1 && (driver[dev_index].flags & DF_INPUT) > 0) {
     sprintf(str, "/Equipment/%s/Settings/Update Threshold", equipment);
     f_threshold = (float) threshold;
     db_set_value_index(hDB, 0, str, &f_threshold, sizeof(float), chn_total, TID_FLOAT, TRUE);
   }

   if (name && name[0]) {
      sprintf(str, "/Equipment/%s/Settings/Names %s", equipment, devname);
      db_set_value_index(hDB, 0, str, name, 32, chn_total, TID_STRING, TRUE);
   }

   /* increment number of channels for this driver */
   driver[dev_index].channels++;
}
  2051   10 Dec 2020 Frederik WautersForumhistory and variables confusion
I wanted to have a c++ style driver, e.g. a instance of a "PowerSupply" class. This was not compatible with the list of DEVICE_DRIVER structs, with needs a C function entry point with variable arguments. 

Anyways, I attach my odb. I believe the issue stands regardless of the specific design choice here. Setting the History Log flag copies the banks created to the "Variables" of every equipments initialized, leading to a mismatch between the names array, and the variables. Can be solved by not using FE history events, but Virtual, but the flag in the Equipment is confusing.  

Bank creation in readout function:

for(const auto& d: drivers)
{
...
...
  bk_create(pevent,bk_name, TID_FLOAT, (void **)&pdata);
...			
  std::vector<float> voltage = d->GetVoltage();
  std::vector<float> current = d->GetCurrent();
  for(channels)
  {
    *pdata++ = voltage.at(iChannel);
    *pdata++ = current.at(iChannel);
  }
  bk_close(pevent, pdata);
}
Attachment 1: genesys.odb
[/Equipment/Genesys/Statistics]
Events sent = DOUBLE : 2
Events per sec. = DOUBLE : 0.2583311805734952
kBytes per sec. = DOUBLE : 0.0268664427796435

[/Equipment/Genesys/Settings]
IP = STRING : [13] 192.168.0.24
NChannels = INT32 : 2
port = INT32 : 8003
Global Reset On FE Start = BOOL : n
Address = INT32[2] :
[0] 0
[1] 1
Identification Code = STRING[2] :
[64] TDK-LAMBDA,GH30-50,114B137-0007,G:02.109
[64] TDK-LAMBDA,GH30-50,114B137-0004,G:02.109
Names = STRING[2] :
[32] ch1
[32] ch2
Blink = BOOL[2] :
[0] n
[1] n
Enable = BOOL : n
reply timout = INT32 : 50
min reply = INT32 : 3
Read ESR = BOOL : n
ESR = INT32[2] :
[0] 0
[1] 0

[/Equipment/Genesys/Variables]
State = BOOL[2] :
[0] y
[1] n
Set State = BOOL[2] :
[0] y
[1] n
Voltage = FLOAT[2] :
[0] 1.997
[1] 0
Demand Voltage = FLOAT[2] :
[0] 2
[1] 0
Current = FLOAT[2] :
[0] 2.03
[1] 0
Current Limit = FLOAT[2] :
[0] 16
[1] 0
LG 0 = FLOAT[4] :
[0] 1.997
[1] 2.03
[2] 0
[3] 0
LH 0 = FLOAT[8] :
[0] 1
[1] 0.0005
[2] 0
[3] 0
[4] 0
[5] 0
[6] 0
[7] 0

[/Equipment/Genesys/Common]
Event ID = UINT16 : 121
Trigger mask = UINT16 : 0
Buffer = STRING : [32] SYSTEM
Type = INT32 : 1
Source = INT32 : 0
Format = STRING : [8] MIDAS
Enabled = BOOL : y
Read on = INT32 : 35
Period = INT32 : 10000
Event limit = DOUBLE : 0
Num subevents = UINT32 : 0
Log history = INT32 : 1
Frontend host = STRING : [32] localhost
Frontend name = STRING : [32] Power Frontend
Frontend file name = STRING : [256] /home/labor/online/backend_pc/midas_fe/power_control/power.cpp
Status = STRING : [256] Ok
Status color = STRING : [32] greenLight
Hidden = BOOL : n
Write cache size = INT32 : 100000

  2052   11 Dec 2020 Frederik WautersForumhistory and variables confusion
1. ok, so calling the same readout functions from different equipments is just a bad idea, my bad, no blame for Midas to write data from both bank to both odb trees ...

2. One needs the same amount of bank entries as the size of settings/names[] . Otherwise the "History Log" flag does not work. So just don`t us "names" but "channel names" or something. 

" Second, it's advisable to group similar equipment into one. Like if you have five power supplies powering
and experiment, you don't want to have five equipments Supply1, Supply2, ..., but only one equipment
"Power Supplies".  "

It would be nice if this also works with c++ style drivers, i.e. a instance of a class. I don`t now how one would give an entry point to the "DEVICE_DRIVER" struct then.



> I wanted to have a c++ style driver, e.g. a instance of a "PowerSupply" class. This was not compatible with the list of DEVICE_DRIVER structs, with needs a C function entry point with variable arguments. 
> 
> Anyways, I attach my odb. I believe the issue stands regardless of the specific design choice here. Setting the History Log flag copies the banks created to the "Variables" of every equipments initialized, leading to a mismatch between the names array, and the variables. Can be solved by not using FE history events, but Virtual, but the flag in the Equipment is confusing.  
> 
> Bank creation in readout function:
> 
> for(const auto& d: drivers)
> {
> ...
> ...
>   bk_create(pevent,bk_name, TID_FLOAT, (void **)&pdata);
> ...			
>   std::vector<float> voltage = d->GetVoltage();
>   std::vector<float> current = d->GetCurrent();
>   for(channels)
>   {
>     *pdata++ = voltage.at(iChannel);
>     *pdata++ = current.at(iChannel);
>   }
>   bk_close(pevent, pdata);
> }
  2053   15 Dec 2020 Konstantin OlchanskiForumhistory and variables confusion
I think you are facing several problems:

a) mlogger does not clearly explain what history names will be used for which entries
in /eq/xxx/variables. "mlogger -v" almost does it, but we also need
"mlogger -v -n" to "show what you will do, but do not do it yet".

b) the mfe.c and the device class driver structure is very dated, tries to "do c++ in c". If it works for you,
certainly use it, but if it confuses you (as it confuses me), it probably only takes a few lines of c++
to replace the whole thing (minus the actual device drivers, which is the meat of it).

It think today, you face a choice:
- invest some time to understand the old device driver framework
- invest some time to do it "by hand" in c++, write your own device drivers (or use 3rd party drivers or snarf the "c" drivers from midas). Use the TMFE C++ frontend class if you go this route.

I would estimate that both choices are about the same amount of work.

K.O.


> 1. ok, so calling the same readout functions from different equipments is just a bad idea, my bad, no blame for Midas to write data from both bank to both odb trees ...
> 
> 2. One needs the same amount of bank entries as the size of settings/names[] . Otherwise the "History Log" flag does not work. So just don`t us "names" but "channel names" or something. 
> 
> " Second, it's advisable to group similar equipment into one. Like if you have five power supplies powering
> and experiment, you don't want to have five equipments Supply1, Supply2, ..., but only one equipment
> "Power Supplies".  "
> 
> It would be nice if this also works with c++ style drivers, i.e. a instance of a class. I don`t now how one would give an entry point to the "DEVICE_DRIVER" struct then.
> 
> 
> 
> > I wanted to have a c++ style driver, e.g. a instance of a "PowerSupply" class. This was not compatible with the list of DEVICE_DRIVER structs, with needs a C function entry point with variable arguments. 
> > 
> > Anyways, I attach my odb. I believe the issue stands regardless of the specific design choice here. Setting the History Log flag copies the banks created to the "Variables" of every equipments initialized, leading to a mismatch between the names array, and the variables. Can be solved by not using FE history events, but Virtual, but the flag in the Equipment is confusing.  
> > 
> > Bank creation in readout function:
> > 
> > for(const auto& d: drivers)
> > {
> > ...
> > ...
> >   bk_create(pevent,bk_name, TID_FLOAT, (void **)&pdata);
> > ...			
> >   std::vector<float> voltage = d->GetVoltage();
> >   std::vector<float> current = d->GetCurrent();
> >   for(channels)
> >   {
> >     *pdata++ = voltage.at(iChannel);
> >     *pdata++ = current.at(iChannel);
> >   }
> >   bk_close(pevent, pdata);
> > }
  2070   08 Jan 2021 Stefan RittForumhistory and variables confusion
We kind of agreed to rewrite the slow control system in C++. Each device will have its own driver derived from a common base class implementing the general communication. The reason we need a "system" and not only a "hand-written" driver is because we want:

- glue many device drivers together for a single equipment
- have a dedicated readout thread for every device, in order not to block other devices
- have a common error reporting scheme working with several threads
- being able to disable/enable individual devices without changing the history system each time
- having a common naming scheme for all devices (like "enforce" /Equipment/<name>/Settings/Names xxx) which is needed by the history system
- ...

Will see when we have time for that.

Stefan
  2446   05 Nov 2022 Zaher SalmanSuggestionhistories capture 'ruy'
The histories capture key events from 'r' 'u' 'y' and 'Escape' for various functions like rescaling etc. However, this also means that if we include an editable modbvalue and a history in the same custom page then changing the modbvalue to something that includes 'ruy' is not possible.

In mhistory.js we have

// Keyboard event handler (has to be on the window!)
window.addEventListener("keydown", this.keyDown.bind(this));

I am not sure why it "has to be on the window". For now, I am bypassing this issue by changing the event listener to "keyup" but maybe there is a more elegant solution for this. Adding the event listener to the div element that includes the history does not seem to work.
  2455   08 Feb 2023 Stefan RittSuggestionhistories capture 'ruy'
> The histories capture key events from 'r' 'u' 'y' and 'Escape' for various functions like rescaling etc. However, this also means that if we include an editable modbvalue and a history in the same custom page then changing the modbvalue to something that includes 'ruy' is not possible.
> 
> In mhistory.js we have
> 
> // Keyboard event handler (has to be on the window!)
> window.addEventListener("keydown", this.keyDown.bind(this));
> 
> I am not sure why it "has to be on the window". For now, I am bypassing this issue by changing the event listener to "keyup" but maybe there is a more elegant solution for this. Adding the event listener to the div element that includes the history does not seem to work.

I could reproduce the problem. I see two options there:

1) We replace 'r' with 'Ctrl-r' etc. 

2) We change the history JS code not to process keyboard inputs if we are currently editing a value.

I added 2) to give it a try. It works fine for me. The additional code is

MhistoryGraph.prototype.keyDown = function (e) {
   // don't consume events if we are editing a value
   if (e.target.tagName === "INPUT")
      return;
   ...
}


Feedback is welcome.

Stefan