    Reply  18 Dec 2003, Paul Knowles, , Poll about default indent style  
Hi Stefan,

> once and forever, I am considering using the "indent" program which comes 
> with every linux installation. Running indent regularly on all our code 
> ensures a consistent look.

I think this can be called a Good Thing.

> The "-kr" style does the standard K&R style, 
> but used tabs (which is not good), and does a 4-column 
> indention which is I think too much. So I would propose 
> following flags:
>        indent -kr -nut -i2 -di8 -bad <filename.c>

(some of this is a repeat from an earlier mail to SR):
You might also want a -l90 for a longer line length than 75
characters.  K&R style with indentation from 5 to 8 spaces
is a good indicator of complexity: as soon as 40 characters
of code wind up unreadably squashed to the right of the
screen, you have to refactor to have less indentation
levels.  This means you wind up rolling up the inner parts
of deeply nested conditionals or loops as separate
functions, making the whole code easier to understand.

I think that setting -i2 is ``going around the problem'' 
of deep nesting.  If you really need to keep the indentation 
tabs less than 4 (8 is ideal) because your code is falling off the 
right edge of the screen, you are indented too deeply.  Why do 
I say that?  There is the famous ``7+-1'' idea that you can hold
in you head only 7 ideas (give or take one) at any time.  I'm not 
that smart and I top out at about 5:  So for example, a conditional 
in a loop  in a conditional in a switch is about as deep a level 
of nesting as  I can easily understand (remember that I also have 
to hold the line i'm working on as well): that's 4 levels, plus one for the
function itself and we are at 40 characters away from the right edge
of the screen using -i8 and have some 40 characters available for writing code
(how often is a line of code really longer than about 40 characters?).
On top of that, the indentation is easily seen so you know immediately 
wheather you are at the upper conditional, or inner conditional.  A -i2
just doesn't make the difference big enough.  -i5 is a happy balance 
with enough visual clue as to the indentation level, but leaves you 50
to 60 characters for the code line itself.

However, if you are indenting very deeply, then the poor reader can't hold
on to the context: there are more than 6 or 7 things to keep in mind.
In those cases, roll up the inner levels as a separate function and 
call it that way. The inner complexity of the nested statements gets 
nicely abstracted and then dumb people like me can understand what 
you are doing.

So, in brief: indent is a good idea, and -in with n>=4 will be best.
I don't think -i2 will lend itself to making the code so much easier 
to read.

thanks for listening.
.p.
Entry  07 Aug 2019, Paolo Baesso, Bug Report, ROOTANA bug? 
Hi,

I posted on the ROOTANA elog but there seems to be little activity there...

Could someone confirm if this is a bug?
https://midas.triumf.ca/elog/Rootana/14

Another user replied that they are encountering the same issue, so I think it is unlikely it is just our installation.

While ROOTANA is unusable for us, I tried to use the example Frontend and Analyzer (under the Experiment source folder). The analyzer does not seem to do much though. A root file is produced but nothing is placed into it. Is that normal?

Any help would be welcome.
Entry  21 May 2024, Nikolay, Bug Report, experiment from midas/examples analyzer.jpg
There are 2 bugs in midas/examples/experiment:

1) In fronted bank named "PRDC" is created for scaler event. But in analyzer 
module scaler.cxx the bank named "SCLR" is searched for the same event.

2) In mana.cxx linked from analyzer.cxx is "Invalid name "/Analyzer/Tests/Always 
true/Rate [Hz]" passed to db_create_key: should not contain "["". 
Looks like ODB doesn't like '[', ']' characters.
    Reply  02 May 2023, Niklaus Berger, Forum, Problem with running midas odbxx frontends on a remote machine using the -h option 
Thanks for all the helpful hints. When finally managing to evade all timeouts and attach the debugger in just the right moment, we find that we get a segfault in mserver at L827:
   case RPC_DB_COPY_XML:
      status = db_copy_xml(CHNDLE(0), CHNDLE(1), CSTRING(2), CPINT(3), CBOOL(4));
Some printf debugging then pointed us to the fact that the culprit is the pointer de-referencing in CBOOL(4). This in turn can be traced back to mrpc.cxx L282 ff, where the line with the arrow was missing:
  {RPC_DB_COPY_XML, "db_copy_xml",
    {{TID_INT32, RPC_IN},
     {TID_INT32, RPC_IN},
     {TID_ARRAY, RPC_OUT | RPC_VARARRAY},
     {TID_INT32, RPC_IN | RPC_OUT},
 ->  {TID_BOOL, RPC_IN},
     {0}}},

If we put that in, the mserver process completes peacfully and we get a segfault in the client ("Wrong key type in XML file") which we will attempt to debug next. Shall I create a pull request for the additional RPC argument or will you just fix this on the fly?
    Reply  02 May 2023, Niklaus Berger, Forum, Problem with running midas odbxx frontends on a remote machine using the -h option 
And now we also fixed the client segfault, odb.cxx L8992 also needs to know about the header:
if (rpc_is_remote())
      return rpc_call(RPC_DB_COPY_XML, hDB, hKey, buffer, buffer_size, header);

(last argument was missing before).
Entry  26 Jul 2019, Nik Berger, Bug Report, History/Endianness 
Hi,
I have a bank of floats with slow control values that I store to the history and
ODB. When reading the history, both in the webbrowser and with mhist, the floats
get read with the wrong endianness; under /equipment/variables in the ODB they
however display correctly. System is a an intel OpenSuse linux box. Any ideas?

Thanks

Nik
Entry  06 Oct 2019, Nik Berger, Bug Report, History data size mismatch 
Logging a list of variables to the history via links in the history ODB subtree,
we get messages as follows at every run start:

19:43:24.009 2019/10/06 [Logger,ERROR] [history_schema.cxx:2676:hs_write_event,ERROR] Event 'System' data size mismatch: expected 412 bytes, got 416 bytes

19:43:24.008 2019/10/06 [Logger,ERROR] [history_schema.cxx:2676:hs_write_event,ERROR] Event 'System' data size mismatch: expected 412 bytes, got 416 bytes

19:43:23.850 2019/10/06 [Logger,ERROR] [history_schema.cxx:455:hs_write_event,ERROR] Event 'System' data size mismatch count: 25, expected 412 bytes, hs_write_event() called with as much as 416 bytes

19:43:23.850 2019/10/06 [Logger,ERROR] [history_schema.cxx:455:hs_write_event,ERROR] Event 'System' data size mismatch count: 25, expected 412 bytes, hs_write_event() called with as much as 416 bytes

The history calculates the size of a record from the size of the individual variables, (history_schema.cxx, L2666 ff), whereas the ODB delivers the data aligned/padded to the size of the largest value in the record.
In our history, a long list of doubles (64 Bit) fas followed by three floats (32 bit), leading to a padded response from the ODB, 4 byte longer than the history expects.
Quick fix: Add another 32 bit dummy variable to the history. Gets rid of the error messages...
Should probably be fixed at a deeper level...
    Reply  10 Oct 2019, Nik Berger, Bug Report, History data size mismatch 
>I wonder why do you this via ODB links. The "standard" way of writing to the history should be to create events for an equipment and flag this equipment as being written to the
>history. All variables under /Equipment/<name>/Variables then automatically go into the history and you don't have to worry about ODB links. Only variables not fitting the
>equipment/variables scheme should be dealt with via ODB links, like variables under equipment/statistics or parameters in another ODB tree. In a typical midas experiment, only
>very few variables typically go into the 'System' event. This is however probably not a solution to your problem. If you have a similar structure (doubles plus an odd number of floats)
>under 'variables', you might get the same error.

>
> In our history, a long list of doubles (64 Bit) fas followed by three floats (32 bit)
>

We do this in the MuX DAQ and mix things that come directly from MIDAS (the MIDAS trigger rate) and things from the
analyzer (rates in the self-triggering detectors) and some temperatures from yet somewhere else. Yes, we could have
kept that apart, yes, in this case a double would also work (and not break things), but a bug is a bug...
I could think of senisble use cases where doubles and ints are mixed and I also know quite a few areas where it makes
sense to use floats...

Nik
Entry  28 Aug 2019, Nick Hastings, Forum, History plot problems for frontend with multiple indicies fedummy.cxxMakefile
Hello experts,

I have been writing a SC frontend for a powersupply. I have used the model 
where the frontend can be started with "-i n" option so that each fe can 
control a different supply. During the development/testing of the program I 
would normally only run a single instance with "-i 1". However when I started
a second instance with "-i 2" I found problems with the history plots that
were being made for the original "-i 1" instance. The variable being plotted
seemed to randomly jump between the value from the "-i 1" instance and 
the "-i 2" instance.  confirmed that the "correct" values exist for each 
frontend in the odb under /Equipment/Foo01/Variables and 
/Equipment/Foo02/Variables

This is also not just a plotting artifact since I was also
able to see the two different values by running mhist.

I saw this behaviour using midas-2019-03 and also the head of the development
branch (686e4de2b55023b0d1936c60bcf4767c5e6caac0 from just under 48 hours ago). 

I was able to reproduce this with a stripped down frontend that just 
sets a variable that is equal to its frontend_index. Please find the code 
and Makefile attached. Presumably I've done something wrong in my 
implementation that hopefully a more experienced person can spot quite 
quickly, but please let me know if any more information is needed.

I have seen this behaviour on both Debian 10 and on a CentOS 7 Singularity 
image running on top of Debian 10.

Thanks,

Nick.

P.S. I made the topic of this post "Forum" and not "Bug Report" since I
expect the root of this problem is somewhere between the keyboard and chair.
    Reply  28 Aug 2019, Nick Hastings, Forum, History plot problems for frontend with multiple indicies 
Hi Stefan,

thanks for you quick reply.

> My first question would be why are you using several font-ends at all?

Becuase I was following the model used for many of the frontends for the ND280 FGD.

> That makes things more 
> complicated than needed. In the normal FE framework, you can define either several equipment 
> served by one frontend, or even one equipment linked to several devices. In the MEG experiment 
> we have one slow control frontend controlling ~100 devices without problem. In the old days 
there 
> was a problem that some slow devices could throttle the readout, but since the invention of 
multi-
> threaded slow control equipment, each device gets its own thread so they don't block each 
other.

Perhaps things have changed in the 10 years since the FGD SC code was written. I can do it 
differently but doing it that way seemed naturual since around 90% of the frontend code that I
have see does it that way.

Nick.
    Reply  29 Aug 2019, Nick Hastings, Forum, History plot problems for frontend with multiple indicies 
Hi LCP,

thanks for the suggestion and link. Unfortunatly I don't think this explains it.

Nick.
    Reply  29 Aug 2019, Nick Hastings, Forum, History plot problems for frontend with multiple indicies 
Hi Ben,

thanks for your reply. I can confirm that your suggested workaround does indeed
make the problem dissapear.

I guess this issue hasn't been seen at T2K since we use MYSQL for the history.

Thanks,

Nick.
    Reply  01 Sep 2019, Nick Hastings, Forum, History plot problems for frontend with multiple indicies 
Hi Ben,

thanks for your reply. I can confirm that your suggested workaround does indeed
make the problem dissapear.

I guess this issue hasn't been seen at T2K since we use MYSQL for the history.

Thanks,

Nick.
    Reply  16 Sep 2019, Nick Hastings, Forum, History plot problems for frontend with multiple indicies 
Hi Konstantin,

thanks for your reply.

> > thanks for your reply. I can confirm that your suggested workaround does indeed
> > make the problem dissapear.
> > I guess this issue hasn't been seen at T2K since we use MYSQL for the history.
> 
> I think you found the source of the problem, confused event id assignments. To confirm,
> can you email me (or post here) the output of odbedit "ls -l /History/Events".

Sorry, do you want this for after I've applied the fix suggested by Ben or with the original code 
that I posted.

With the original code it only shows one fe even though both are running:

[local:e666:S]History>ls -l /History/Events
Key name                        Type    #Val  Size  Last Opn Mode Value
---------------------------------------------------------------------------
1                               STRING  1     10    2m   0   RWD  FeDummy02
0                               STRING  1     16    2m   0   RWD  Run transitions

[local:e666:S]History> scl
Name                Host
mhttpd              localhost           
fedummy01           localhost           
fedummy02           localhost           
ODBEdit             localhost           
Logger              localhost           
[local:e666:S]History>ls "/History/Display/Default/Dummy/
Timescale                       1h
Zero ylow                       n
Show run markers                y
Show values                     y
Sort Vars                       n
Log axis                        n
Minimum                         0
Maximum                         0
Variables
                                FeDummy01:Data
                                FeDummy02:Data
Label
                                
                                
Colour
                                #00AAFF
                                #FF9000
Factor
                                0
                                0
Offset
                                0
                                0
Buttons
                                10m
                                1h
                                3h
                                12h
                                24h
                                3d
                                7d
Formula
                                
                                
Show old vars                   n

> If that's the problem, you can avoid it completely by switching to a history storage method
> that does not rely on magic mapping between equipment names and numeric event id's:
> try the "FILE" method (set odb /Logger/History/FILE/Active to "y", restart the logger) or
> the "MYSQL" method (you will need to setup a mysql database). You tell mhttpd and mhist which 
> history data to read by setting ODB /History/LoggerHistoryChannel to one of the channel names 
> from /logger/history/, restart mhttpd. (mhttpd and mhist used to print a message "reading history 
> data from channel XXX", but somebody removed this message).

Using the orginal code I posted and switching from MIDAS history to FILE history did not seem to 
change the random behaviour in the history plots.

Regards,

Nick.
    Reply  18 Sep 2019, Nick Hastings, Forum, History plot problems for frontend with multiple indicies 
> > [local:e666:S]History>ls -l /History/Events
> > Key name                        Type    #Val  Size  Last Opn Mode Value
> > ---------------------------------------------------------------------------
> > 1                               STRING  1     10    2m   0   RWD  FeDummy02
> > 0                               STRING  1     16    2m   0   RWD  Run transitions
> 
> Something is very broken. There should be more entries here, at least
> there should be entries for "FeDummy01" and usually there is also an entry
> for "FeDummy" because one invariably runs fedummy without "-i" at least once.
> 
> The fact that changing from "midas" storage to "file" storage makes no difference
> also indicates that something is very broken.
> 
> I want to debug this.
> 
> Since you tried the "file" storage, can you send me the output of "ls -l mhf*.dat" in the directory
> with the history files? (it should have the "*.hst" files from the "midas" storage and "mhf*.dat" files
> from the "file" storage.


> 
> K.O.
    Reply  18 Sep 2019, Nick Hastings, Forum, History plot problems for frontend with multiple indicies 
Hi Konstantin,

> > [local:e666:S]History>ls -l /History/Events
> > Key name                        Type    #Val  Size  Last Opn Mode Value
> > ---------------------------------------------------------------------------
> > 1                               STRING  1     10    2m   0   RWD  FeDummy02
> > 0                               STRING  1     16    2m   0   RWD  Run transitions
> 
> Something is very broken. There should be more entries here, at least
> there should be entries for "FeDummy01" and usually there is also an entry
> for "FeDummy" because one invariably runs fedummy without "-i" at least once.

This is a fresh experiment that I started just to test this this issue, that is why there are not many 
entries in /History/Events. I agree though that we should expect to see a FeDummy01 entry.
 
> The fact that changing from "midas" storage to "file" storage makes no difference
> also indicates that something is very broken.
> 
> I want to debug this.
> 
> Since you tried the "file" storage, can you send me the output of "ls -l mhf*.dat" in the directory
> with the history files? (it should have the "*.hst" files from the "midas" storage and "mhf*.dat" 
files
> from the "file" storage.

When I started this experiment yesterday(?) I disabled the Midas history when I enbled the file 
history. Jsut now I reenabled the Midas history, so they are currently both active.

% ls -l work/online/{*.hst,mhf*.dat}
-rw-r--r-- 1 hastings hastings  14996 Sep 17 10:21 work/online/190917.hst
-rw-r--r-- 1 hastings hastings   3292 Sep 18 16:29 work/online/190918.hst
-rw-r--r-- 1 hastings hastings 867288 Sep 18 16:29 work/online/mhf_1568683062_20190917_fedummy01.dat
-rw-r--r-- 1 hastings hastings 867288 Sep 18 16:29 work/online/mhf_1568683062_20190917_fedummy02.dat
-rw-r--r-- 1 hastings hastings    166 Sep 17 10:17 
work/online/mhf_1568683062_20190917_run_transitions.dat

And again, just as a sanity check:

% odbedit -c 'ls -l /History/Events'
Key name                        Type    #Val  Size  Last Opn Mode Value
---------------------------------------------------------------------------
1                               STRING  1     10    1m   0   RWD  FeDummy02
0                               STRING  1     16    1m   0   RWD  Run transitions

Regards,

Nick.
    Reply  27 May 2021, Nick Hastings, Bug Report, Wrong location for mysql.h on our Linux systems 
Hi,

> with the recent fix of the CMakeLists.txt, it seems like another bug 
surfaced. 
> In midas/progs/mlogger.cxx:48/49, the mysql header files are included without 
a 
> prefix. However, mysql.h and mysqld_error.h are in a subdirectory, so for our 
> systems, the lines should be
>   48 #include <mysql/mysql.h>
>   49 #include <mysql/mysqld_error.h>
> This is the case with MariaDB 10.5.5 on OpenSuse Leap 15.2, MariaDB 10.5.5 on 
> Fedora Workstation 34 and MySQL 5.5.60 on Raspbian 10.
> 
> If this problem occurs for other Linux/MySQL versions as well, it should be 
> fixed in mlogger.cxx and midas/src/history_schema.cxx.
> If this problem only occurs on some distributions or MySQL versions, it needs 
> some more differentiation than #ifdef OS_UNIX.

What does "mariadb_config --cflags" or "mysql_config --cflags" return on 
these systems? For mariadb 10.3.27 on Debian 10 it returns both paths:

% mariadb_config --cflags
-I/usr/include/mariadb -I/usr/include/mariadb/mysql

Note also that mysql.h and mysqld_error.h reside in /usr/include/mariadb *not* 
/usr/include/mariadb/mysql so using "#include <mysql/mysql.h>" would not work.

On CentOS 7 with mariadb  5.5.68:

%  mysql_config --include
-I/usr/include/mysql
% ls -l /usr/include/mysql/mysql*.h
-rw-r--r--. 1 root root 38516 May  6  2020 /usr/include/mysql/mysql.h
-r--r--r--. 1 root root 76949 Oct  2  2020 /usr/include/mysql/mysqld_ername.h
-r--r--r--. 1 root root 28805 Oct  2  2020 /usr/include/mysql/mysqld_error.h
-rw-r--r--. 1 root root 24717 May  6  2020 /usr/include/mysql/mysql_com.h
-rw-r--r--. 1 root root  1167 May  6  2020 /usr/include/mysql/mysql_embed.h
-rw-r--r--. 1 root root  2143 May  6  2020 /usr/include/mysql/mysql_time.h
-r--r--r--. 1 root root   938 Oct  2  2020 /usr/include/mysql/mysql_version.h

So this seems to be the correct setup for both Debian and RHEL. If this is to 
be worked around in Midas I would think it would be better to do it at the 
cmake level than by putting another #ifdef in the code.

Cheers,

Nick.
Entry  24 Jul 2023, Nick Hastings, Bug Report, Incompatible data types with mysql odbc interface 
Hello,

I have recently set up a midas-2022-05-c instance and have been trying to configure
it to use the mysql odbc interface. Tables are being created for it but
the logger is issuing errors that some of the column types are incorrect. For example
in the log I see:

14:22:12.689 2023/07/25 [Logger,ERROR] [history_odbc.cxx:1531:hs_define_event,ERROR] Error: History event 'Run transitions': Incompatible data type for tag 'State' type 'UINT32', SQL column 'state' type 'INT UNSIGNED'
14:22:12.689 2023/07/25 [Logger,ERROR] [history_odbc.cxx:1531:hs_define_event,ERROR] Error: History event 'Run transitions': Incompatible data type for tag 'Run number' type 'UINT32', SQL column 'run_number' type 'INT UNSIGNED'

Checking the table in the database I see:

MariaDB [t2kgscND280]> describe run_transitions;
+------------+------------------+------+-----+---------------------+-------------------------------+
| Field      | Type             | Null | Key | Default             | Extra                         |
+------------+------------------+------+-----+---------------------+-------------------------------+
| _t_time    | timestamp        | NO   | MUL | current_timestamp() | on update current_timestamp() |
| _i_time    | int(11)          | NO   | MUL | NULL                |                               |
| state      | int(10) unsigned | YES  |     | NULL                |                               |
| run_number | int(10) unsigned | YES  |     | NULL                |                               |
+------------+------------------+------+-----+---------------------+-------------------------------+
4 rows in set (0.000 sec)

Please note that this is not the only history variable that has this problem. There are multiple variables
for which:

Incompatible data type for tag 'Foo Bar' type 'UINT32', SQL column 'foo_bar' type 'INT UNSIGNED'

Checking history_odbc.cxx, I see:

static const char *sql_type_mysql[] = {
   "xxxINVALIDxxxNULL", // TID_NULL
   "tinyint unsigned",  // TID_UINT8
   "tinyint",           // TID_INT8
   "char",              // TID_CHAR
   "smallint unsigned", // TID_UINT16
   "smallint",          // TID_INT16
   "integer unsigned",  // TID_UINT32
   "integer",           // TID_INT32
   "tinyint",           // TID_BOOL
   "float",             // TID_FLOAT
   "double",            // TID_DOUBLE
   "tinyint unsigned",  // TID_BITFIELD
   "VARCHAR",           // TID_STRING
   "xxxINVALIDxxxARRAY",
   "xxxINVALIDxxxSTRUCT",
   "xxxINVALIDxxxKEY",
   "xxxINVALIDxxxLINK"
};

So it seems that unsigned int should map to UINT32.

The database is:
Server version: 10.5.16-MariaDB MariaDB Server

Please let me know if more information is needed.

Note that the choice of using the odbc interface is because we
plan to import an old database that was created using the odbc interface
with a previous version of midas (yes this is your old friend T2K/ND280).

Regards,

Nick.
    Reply  25 Jul 2023, Nick Hastings, Bug Report, Incompatible data types with mysql odbc interface 
Hello,

wanted add few things:

1. I see the same problem for INT32
2. For now I've worked around these problems with https://bitbucket.org/nickhastings/midas/commits/e4776f7511de0647077c8c80d43c17bbfe2184fd
3. I'm using mariadb-connector-odbc-3.1.12-3.el9.x86_64 (System is AlmaLinux 9)

Regards,

Nick.
Entry  08 Sep 2023, Nick Hastings, Forum, Hide start and stop buttons 
The wiki documents an odb variable to enable the hiding of the Start and Stop buttons on the mhttpd status page
https://daq00.triumf.ca/MidasWiki/index.php//Experiment_ODB_tree#Start-Stop_Buttons

However mhttpd states this option is obsolete. See commit:
https://bitbucket.org/tmidas/midas/commits/2366eefc6a216dc45154bc4594e329420500dcf7

I note that that commit also made mhttpd report that the "Pause-Resume Buttons" variable is also obsolete, however that code seems to have since been removed.

Is there now some other mechanism to hide the start and stop buttons?
Note that this is for a pure slow control system that does not take runs.