Back Midas Rome Roody Rootana
  Midas DAQ System, Page 73 of 152  Not logged in ELOG logo
ID Date Author Topic Subjectdown Text Attachments
  315   26 Oct 2006 Hans FynboForumSetup of Ortec ADC AD413A in MIDASWe are new to MIDAS and try to setup a simple
system with one ortec camac ADC
AD413A and the hytec1331 controler. Has anyone
  
  2472   21 Apr 2023 Grzegorz NieradkaForumSetup Midas with Caen vx2740 - ask for helpI'm trying to setup Midas with the Caen vx2740
VME digitizer board.
As the backend driver I used the software
  
  2473   21 Apr 2023 Ben SmithForumSetup Midas with Caen vx2740 - ask for help> I'm not able to find documentation what
is purpose of the RPC? Could someone give
any indicators how I can start debug this
  
  2474   21 Apr 2023 Konstantin OlchanskiForumSetup Midas with Caen vx2740 - ask for help> I'm trying to setup Midas with the Caen
vx2740 VME digitizer board.
  
  1874   07 Apr 2020 Ivo SchulthessSuggestionSequencer loop breakI am using the Midas sequencer to run subsequent
measurements in a loop, without 
knowing how many iterations in advance. Therefore,
  
  1875   21 Apr 2020 Stefan RittSuggestionSequencer loop break> I am using the Midas sequencer to run subsequent
measurements in a loop, without 
> knowing how many iterations in advance.
  
  1876   23 Apr 2020 Ivo SchulthessSuggestionSequencer loop break> You can do that with the "GOTO" statement,
jumping to the first line after the loop.
  
  1877   23 Apr 2020 Stefan RittSuggestionSequencer loop break> > You can do that with the "GOTO" statement,
jumping to the first line after the loop.
> > 
  
  1885   25 Apr 2020 Konstantin OlchanskiSuggestionSequencer loop break> LOOP runs, 5
> ...
> ENDLOOP
  
  1094   19 Aug 2015 Pierre GorelBug ReportSequencer limitsWhile I know some of those limits/problems
have been already been reported from
DEAP (and maybe corrected in the last version),
  
  1095   19 Aug 2015 Pierre-Andre AmaudruzBug ReportSequencer limitsThese issues have been addressed by Stefan
during his visit at Triumf last month.
The latest git has those fixes.
  
  1096   19 Aug 2015 Konstantin OlchanskiBug ReportSequencer limits
> See LOOP doc
>  LOOP cnt, 10
  
  1097   20 Aug 2015 Stefan RittBug ReportSequencer limits> > - ODBGet (and ODBSet?) does seem to be
able to take a variable as a path... I
> > was trying to use an array whose index
  
  2303   19 Nov 2021 Jacob ThorneForumSequencer error with ODB IncHi,

I am having problems with the midas sequencer,
  
  2306   02 Dec 2021 Stefan RittForumSequencer error with ODB IncThanks for reporting that bug. Indeed there
was a problem in the sequencer code which
I fixed now. Please try the updated develop
  
  2732   02 Apr 2024 Zaher SalmanInfoSequencer editorDear all,
Stefan and I have been working on improving
the sequencer editor to make it look and
 Seq1.pngSeq2.png 
  2733   02 Apr 2024 Konstantin OlchanskiInfoSequencer editor> Stefan and I have been working on improving
the sequencer editor ...
  
  3013   01 Apr 2025 Lukas GerritzenSuggestionSequencer ODBSET feature requestsI would like to request the following sequencer
features if you find the ideas as sensible
as I do:
  
  3014   01 Apr 2025 Lukas GerritzenSuggestionSequencer ODBSET feature requestsWhile trying to simplify the existing spaghetti
code, I encountered problems with type safety.
Compare the following:
  
  3015   01 Apr 2025 Stefan RittSuggestionSequencer ODBSET feature requestsA new sequencer which understands Python is
in the works. There you can use all features
from that language.
  
ELOG V3.1.4-2e1708b5