  1719   06 Oct 2019 Nik BergerBug ReportHistory data size mismatchLogging a list of variables to the history
via links in the history ODB subtree,
we get messages as follows at every run start:
  
  1720   06 Oct 2019 Stefan RittBug ReportHistory data size mismatchI wonder why do you this via ODB links. The
"standard" way of writing to the history
should be to create events for an equipment
  
  1721   10 Oct 2019 Konstantin OlchanskiBug ReportHistory data size mismatch>
> In our history, a long list of doubles
(64 Bit) fas followed by three floats (32
  
  1722   10 Oct 2019 Nik BergerBug ReportHistory data size mismatch>I wonder why do you this via ODB links. The
"standard" way of writing to the history
should be to create events for an equipment
  
  1723   10 Oct 2019 Stefan RittBug ReportHistory data size mismatch> Yes, we could have
> kept that apart, yes, in this case a double
would also work (and not break things), but
  
  473   23 Mar 2008 Konstantin OlchanskiInfoHistory SQL database poll: MySQL, PgSQL, ODBC?I would like to hear from potential users
on which SQL database would be
preferable for storage of MIDAS history data.
  
  Draft   20 Jun 2017 Richard LonglandForumHigh Rate    
  2595   08 Sep 2023 Nick HastingsForumHide start and stop buttonsThe wiki documents an odb variable to enable
the hiding of the Start and Stop buttons
on the mhttpd status page
  
  2596   08 Sep 2023 Nick HastingsForumHide start and stop buttons> Is there now some other mechanism to hide
the start and stop buttons?
> Note that this is for a pure slow control
  
  2599   13 Sep 2023 Stefan RittForumHide start and stop buttonsIndeed the ODB settings are obsolete. Now
that the status page is fully dynamic 
(JavaScript), it's much more powerful to
  
  2600   13 Sep 2023 Nick HastingsForumHide start and stop buttonsHi Stefan,

> Indeed the ODB settings are obsolete.
 screenshot-20230914-085054.png 
  2601   13 Sep 2023 Stefan RittForumHide start and stop buttons> Hi Stefan,

> > Indeed the ODB settings are obsolete.
  
  2602   14 Sep 2023 Konstantin OlchanskiForumHide start and stop buttonsI believe the original "hide run start / stop"
was added specifically for ND280 GSC MIDAS.
I do not know 
  
  2603   14 Sep 2023 Nick HastingsForumHide start and stop buttonsHi

> > > Indeed the ODB settings are obsolete.
  
  2604   14 Sep 2023 Stefan RittForumHide start and stop buttons> I believe the original "hide run start /
stop" was added specifically for ND280 GSC
MIDAS. I do not know 
  
  2605   15 Sep 2023 Stefan RittForumHide start and stop buttons> I believe the original "hide run start /
stop" was added specifically for ND280 GSC
MIDAS. I do not know 
  
  2811   25 Aug 2024 Adrian FisherInfoHelp parsing scdms_v1 data?Hi! I'm working on creating a ksy file to
help with parsing some data, but I'm having
trouble finding some information. Right now,
  
  2812   26 Aug 2024 Stefan RittInfoHelp parsing scdms_v1 data?The MIDAS event format is described here:

  https://daq00.triumf.ca/MidasWiki/index.php/Event_Structure
  
  2813   26 Aug 2024 Adrian FisherInfoHelp parsing scdms_v1 data?[quote="Stefan Ritt"]The MIDAS event format
is described here:
  
  2836   11 Sep 2024 Konstantin OlchanskiInfoHelp parsing scdms_v1 data?Look at the C++ implementation of the MIDAS
data file reader, the code is very 
simple to follow.
  