ID |
Date |
Author |
Topic |
Subject |
Text |
|
1719
|
06 Oct 2019 |
Nik Berger | Bug Report | History data size mismatch | Logging a list of variables to the history
via links in the history ODB subtree,
we get messages as follows at every run start:
|
|
1720
|
06 Oct 2019 |
Stefan Ritt | Bug Report | History data size mismatch | I wonder why do you this via ODB links. The
"standard" way of writing to the history
should be to create events for an equipment |
|
1721
|
10 Oct 2019 |
Konstantin Olchanski | Bug Report | History data size mismatch | >
> In our history, a long list of doubles
(64 Bit) fas followed by three floats (32 |
|
1722
|
10 Oct 2019 |
Nik Berger | Bug Report | History data size mismatch | >I wonder why do you this via ODB links. The
"standard" way of writing to the history
should be to create events for an equipment |
|
1723
|
10 Oct 2019 |
Stefan Ritt | Bug Report | History data size mismatch | > Yes, we could have
> kept that apart, yes, in this case a double
would also work (and not break things), but |
|
473
|
23 Mar 2008 |
Konstantin Olchanski | Info | History SQL database poll: MySQL, PgSQL, ODBC? | I would like to hear from potential users
on which SQL database would be
preferable for storage of MIDAS history data.
|
|
Draft
|
20 Jun 2017 |
Richard Longland | Forum | High Rate | |
|
2595
|
08 Sep 2023 |
Nick Hastings | Forum | Hide start and stop buttons | The wiki documents an odb variable to enable
the hiding of the Start and Stop buttons
on the mhttpd status page
|
|
2596
|
08 Sep 2023 |
Nick Hastings | Forum | Hide start and stop buttons | > Is there now some other mechanism to hide
the start and stop buttons?
> Note that this is for a pure slow control |
|
2599
|
13 Sep 2023 |
Stefan Ritt | Forum | Hide start and stop buttons | Indeed the ODB settings are obsolete. Now
that the status page is fully dynamic
(JavaScript), it's much more powerful to |
|
2600
|
13 Sep 2023 |
Nick Hastings | Forum | Hide start and stop buttons | Hi Stefan,
> Indeed the ODB settings are obsolete.
|
|
2601
|
13 Sep 2023 |
Stefan Ritt | Forum | Hide start and stop buttons | > Hi Stefan,
>
> > Indeed the ODB settings are obsolete.
|
|
2602
|
14 Sep 2023 |
Konstantin Olchanski | Forum | Hide start and stop buttons | I believe the original "hide run start / stop"
was added specifically for ND280 GSC MIDAS.
I do not know
|
|
2603
|
14 Sep 2023 |
Nick Hastings | Forum | Hide start and stop buttons | Hi
> > > Indeed the ODB settings are obsolete.
|
|
2604
|
14 Sep 2023 |
Stefan Ritt | Forum | Hide start and stop buttons | > I believe the original "hide run start /
stop" was added specifically for ND280 GSC
MIDAS. I do not know
|
|
2605
|
15 Sep 2023 |
Stefan Ritt | Forum | Hide start and stop buttons | > I believe the original "hide run start /
stop" was added specifically for ND280 GSC
MIDAS. I do not know
|
|
2811
|
25 Aug 2024 |
Adrian Fisher | Info | Help parsing scdms_v1 data? | Hi! I'm working on creating a ksy file to
help with parsing some data, but I'm having
trouble finding some information. Right now, |
|
2812
|
26 Aug 2024 |
Stefan Ritt | Info | Help parsing scdms_v1 data? | The MIDAS event format is described here:
https://daq00.triumf.ca/MidasWiki/index.php/Event_Structure
|
|
2813
|
26 Aug 2024 |
Adrian Fisher | Info | Help parsing scdms_v1 data? | [quote="Stefan Ritt"]The MIDAS event format
is described here:
|
|
2836
|
11 Sep 2024 |
Konstantin Olchanski | Info | Help parsing scdms_v1 data? | Look at the C++ implementation of the MIDAS
data file reader, the code is very
simple to follow.
|
|