Back Midas Rome Roody Rootana
  Midas DAQ System, Page 145 of 146  Not logged in ELOG logo
    Reply  17 Aug 2006, Stefan Ritt, Bug Report, "double" values are truncated 
> The mhttpd ODB displays and mhist truncate values of "float" and "double"
> floating point variables to 6 digits. In reality, "float" has 7 significant
> digits and "double" has 16. I recommend that db_sprintf() in odb.c be changed to
    Reply  16 Dec 2004, Konstantin Olchanski, Info, "cd /" in ss_daemon_init(), was- Commit local TWIST modifications 
> > - system.c: do not chdir("/") in ss_daemon_init()- it prevents us from ever
> >   getting core dumps from midas daemons.
Entry  06 Sep 2012, shaun, Bug Report, "cannot find recent history file" 
Hi, when attempting to access a history window the following message is repeated
over and over in the MIDAS message log:
Entry  31 Jan 2023, Lukas Gerritzen, Suggestion, "Soft interlock" possible? 
Is it possible to impose requirements on certain output variables in an interlock-like fashion? For example: "As long as the temperature exceeds a certain
threshold, a light switched by a relay cannot be turned on."
    Reply  31 Jan 2023, Stefan Ritt, Suggestion, "Soft interlock" possible? 
> Is it possible to impose requirements on certain output variables in an interlock-like fashion? For example: "As long as the temperature exceeds a certain
threshold, a light switched by a relay cannot be turned on."
Entry  15 Aug 2024, Scott Oser, Forum, "Safe" abort of sequencer scripts 
We often use the MIDAS sequencer to temporarily control detector settings, such as:

* <change some setting>
    Reply  19 Aug 2024, Stefan Ritt, Forum, "Safe" abort of sequencer scripts 
This request came more than once in the past. One thing I could implement is a "atexit" function similarly to the C funciton atexit().

Then we would have a function in the script which gets called whenever one does "stop immediately". This function can then restore
    Reply  22 Aug 2024, Scott Oser, Forum, "Safe" abort of sequencer scripts 
> This request came more than once in the past. One thing I could implement is a "atexit" function similarly to the C funciton atexit().

> Then we would have a function in the script which gets called whenever one does "stop immediately". This function can then restore
    Reply  11 Sep 2024, Konstantin Olchanski, Forum, "Safe" abort of sequencer scripts 
> We often use the MIDAS sequencer to temporarily control detector settings, such as:

> * <change some setting>
    Reply  02 Dec 2024, Stefan Ritt, Forum, "Safe" abort of sequencer scripts 
The atexit() function has been implemented in the current develop branch of midas, see

  https://daq00.triumf.ca/MidasWiki/index.php/Sequencer#ATEXIT_subroutine
Entry  16 Jun 2008, Stefan Ritt, Bug Fix, "Missing event" problem fixed in front-end framework 
Since the very beginning midas had the problem that the last event of a run was
sometimes missing in the data. While for most experiments this is not an issue,
it starts to hurt on experiments using event building (front-end 1 and front-end
    Reply  10 Mar 2008, Exaos Lee, Suggestion, "Makefile-by-EL" updated Makefile-by-EL
> Not that the current Makefile is too pretty (I have seen worse), but it 
works and it is fairly compact for a project of 
> this complexity, it handles a large number of operating systems and build 
    Reply  10 Mar 2008, Exaos Lee, Suggestion, "Makefile-by-EL" updated 
Sorry, this line:
[CODE]EXECS += $(EXAMPLES:%/$(BIN_DIR)/%)[/CODE]
should be replaced by
    Reply  11 Mar 2008, Stefan Ritt, Suggestion, "Makefile-by-EL" updated 
The linking of mhttpd misses a "-lm":

cc -g -O3 -Wall -Wuninitialized -DINCLUDE_FTPLIB -D_LARGEFILE64_SOURCE -DOS_LINUX
    Reply  11 Mar 2008, Exaos Lee, Suggestion, "Makefile-by-EL" updated 
> The linking of mhttpd misses a "-lm":

> cc -g -O3 -Wall -Wuninitialized -DINCLUDE_FTPLIB -D_LARGEFILE64_SOURCE -DOS_LINUX
Entry  26 May 2014, Dan Melconian, Suggestion, "Edit-on-end" would be nice 
We use the "Edit-on-start" and it's great.  But sometimes, something breaks
during the run, or you didn't realize you forgot to plug in a cable, or
whatever.  It'd be nice to have an "Edit-on-end" where you could prompt the user
    Reply  26 May 2014, Stefan Ritt, Suggestion, "Edit-on-end" would be nice 
We have similar demands, and we solve it in the following:

We use a run database. In the simplest case, this can be a text file which gets written at the end of the file. The 
Entry  19 Aug 2022, Konstantin Olchanski, Bug Fix, "Detected duplicate or non-monotonous data" in history files 
serious (but rare) bug was fixed in the history reader. unlucky experiment would see 
errors about "Detected duplicate or non-monotonous data" in some history file, fixed by 
removing/renaming the offending file. (reported by MEG experiment)
    Reply  23 Aug 2022, Konstantin Olchanski, Bug Fix, "Detected duplicate or non-monotonous data" in history files 
> serious (but rare) bug was fixed in the history reader.

previous fix was incomplete. please update to git commit
    Reply  17 Nov 2022, Konstantin Olchanski, Bug Fix, "Detected duplicate or non-monotonous data" in history files 
> > serious (but rare) bug was fixed in the history reader.
> previous fix was incomplete. please update to git commit
> https://bitbucket.org/tmidas/midas/commits/b343c3c98e4e6fd00a00cf686c74c7ccc6da0c63
ELOG V3.1.4-2e1708b5