Back Midas Rome Roody Rootana
  Midas DAQ System, Page 40 of 138  Not logged in ELOG logo
Entry  13 Mar 2017, Konstantin Olchanski, Info, improved mhttpd sounds 
I reworked the alarm sounds in mhttpd - now you can turn off all sounds without disabling the 
alarm system for everybody.
Entry  13 Jul 2017, Konstantin Olchanski, Info, implemented: json-rpc batch requests 
The mhttpd json-rpc interface now implements batch requests per
http://www.jsonrpc.org/specification#batch
Entry  08 Sep 2019, Vinzenz Bildstein, Bug Report, https redirect and ODB access 
I'm not sure if these issues are related or not, but I'm getting an error
message when I want to access the root of the ODB via the webserver:
[mhttpd,ERROR] [mhttpd.cxx:563:rread,ERROR] Cannot read file '/root', read of
    Reply  16 Sep 2019, Konstantin Olchanski, Bug Report, https redirect and ODB access 
> I'm not sure if these issues are related or not, but I'm getting an error
> message when I want to access the root of the ODB via the webserver:
> [mhttpd,ERROR] [mhttpd.cxx:563:rread,ERROR] Cannot read file '/root', read of
Entry  04 Jan 2013, Nabin Poudyal, Suggestion, how to start using midas 
Please, tell me how to choose a value of a "key" like DCM, pulser period,
presamples, upper thresholds to run a experiment? where can I find the related
informations? 
Entry  20 Aug 2007, Konstantin Olchanski, Bug Report, how to handle end of run? 
I am having problems with handling the end-of-run situation in my midas
frontend. I have a device that continuously sends data (over USB) and I read
this data in my "read_event" function.
    Reply  03 Sep 2007, Stefan Ritt, Bug Report, how to handle end of run? 
> I am having problems with handling the end-of-run situation in my midas
> frontend. I have a device that continuously sends data (over USB) and I read
> this data in my "read_event" function.
Entry  09 Dec 2023, Pavel Murat, Forum, how to fix forgotten password ? 
[Dear All, I apologize in advance for spamming.]

1) I tried to login into the forum from the lab computer and realized 
Entry  29 Aug 2008, Konstantin Olchanski, Info, history_odbc: store MIDAS history in ODBC/MySQL database 
The code for storing midas history in an odbc sql database has been committed.
Changes:
include/history_odbc.h, src/history_odbc.cxx --- implementation
Entry  24 Feb 2021, Zaher Salman, Bug Report, history reload 
I have a history that is embedded in a custom page using

<div class="mjshistory" data-group="SampleCryo" data-panel="SampleTemp" data-scale="30m" style="'+size+' position: relative;left: 640px;top: -205px;"></div>
    Reply  25 Feb 2021, Stefan Ritt, Bug Report, history reload 
I have to reproduce the problem. Can you please send me the full link by direct email. As you know, I'm also at PSI.

Stefan
Entry  09 Dec 2023, Pavel Murat, Forum, history plotting: where to convert the ADC readings into temps/voltages? 
to plot time dependencies of the monitored detector parameters, say, voltages or temperatures,
one needs to convert the coresponging ADC readings into floats.
    Reply  10 Dec 2023, Stefan Ritt, Forum, history plotting: where to convert the ADC readings into temps/voltages? 
> to plot time dependencies of the monitored detector parameters, say, voltages or temperatures,
> one needs to convert the coresponging ADC readings into floats.
Entry  09 Dec 2020, Frederik Wauters, Forum, history and variables confusion 
I have a fe, with 2 "equipments" (2 different types of LV supplies).

Equipment/../Setting has a "Names" key, with the actual channel names (ch1, ch2, ...) of the devices.
    Reply  09 Dec 2020, Stefan Ritt, Forum, history and variables confusion 
First, the writing of banks is completely independent of the history system. Banks go to the log file only, 
while the history is only linked to the "Variables" section in the ODB.
    Reply  10 Dec 2020, Frederik Wauters, Forum, history and variables confusion genesys.odb
I wanted to have a c++ style driver, e.g. a instance of a "PowerSupply" class. This was not compatible with the list of DEVICE_DRIVER structs, with needs
a C function entry point with variable arguments. 
    Reply  11 Dec 2020, Frederik Wauters, Forum, history and variables confusion 
1. ok, so calling the same readout functions from different equipments is just a bad idea, my bad, no blame for Midas to write data from both bank to both
odb trees ...
    Reply  15 Dec 2020, Konstantin Olchanski, Forum, history and variables confusion 
I think you are facing several problems:

a) mlogger does not clearly explain what history names will be used for which entries
    Reply  08 Jan 2021, Stefan Ritt, Forum, history and variables confusion 
We kind of agreed to rewrite the slow control system in C++. Each device will have its own driver derived from a common base class implementing the general
communication. The reason we need a "system" and not only a "hand-written" driver is because we want:
Entry  05 Nov 2022, Zaher Salman, Suggestion, histories capture 'ruy' 
The histories capture key events from 'r' 'u' 'y' and 'Escape' for various functions like rescaling etc. However, this also means that if we include an
editable modbvalue and a history in the same custom page then changing the modbvalue to something that includes 'ruy' is not possible.