    Reply  23 Apr 2020, Ivo Schulthess, Suggestion, Sequencer loop break 
> You can do that with the "GOTO" statement, jumping to the first line after the loop.

> Here is a working example:
    Reply  23 Apr 2020, Stefan Ritt, Suggestion, Sequencer loop break 
> > You can do that with the "GOTO" statement, jumping to the first line after the loop.
> > 
> > Here is a working example:
    Reply  25 Apr 2020, Konstantin Olchanski, Suggestion, Sequencer loop break 
> LOOP runs, 5
> ...
> ENDLOOP
Entry  19 Aug 2015, Pierre Gorel, Bug Report, Sequencer limits 
While I know some of those limits/problems have been already been reported from
DEAP (and maybe corrected in the last version), I am recording them here:
    Reply  19 Aug 2015, Pierre-Andre Amaudruz, Bug Report, Sequencer limits 
These issues have been addressed by Stefan during his visit at Triumf last month.
The latest git has those fixes.
    Reply  19 Aug 2015, Konstantin Olchanski, Bug Report, Sequencer limits 

> See LOOP doc
>  LOOP cnt, 10
    Reply  20 Aug 2015, Stefan Ritt, Bug Report, Sequencer limits 
> > - ODBGet (and ODBSet?) does seem to be able to take a variable as a path... I
> > was trying to use an array whose index would be incremented.
Entry  19 Nov 2021, Jacob Thorne, Forum, Sequencer error with ODB Inc 
Hi,

I am having problems with the midas sequencer, here is my code:
    Reply  02 Dec 2021, Stefan Ritt, Forum, Sequencer error with ODB Inc 
Thanks for reporting that bug. Indeed there was a problem in the sequencer code which I fixed now. Please try the updated develop branch.

Stefan
Entry  02 Apr 2024, Zaher Salman, Info, Sequencer editor Seq1.pngSeq2.png
Dear all,
Stefan and I have been working on improving the sequencer editor to make it look and feel more like a standard editor. This sequencer v2 has been finally
merged into the develop branch earlier today. 
    Reply  02 Apr 2024, Konstantin Olchanski, Info, Sequencer editor 
> Stefan and I have been working on improving the sequencer editor ...

Looks grand! Congratulations with getting it completed. The previous version was 
Entry  31 Jan 2014, Stefan Ritt, Info, Separation of MSCB subtree 
Since several projects at PSI need MSCB but not MIDAS, I decided to separate the two repositories. So if you 
need MIDAS with MSCB support inside mhttpd, you have to clone MIDAS, MXML and MSCB from bitbucket 
(or the local clone at TRIUMF) as described in
    Reply  18 Feb 2014, Konstantin Olchanski, Info, Separation of MSCB subtree 
> Since several projects at PSI need MSCB but not MIDAS, I decided to separate the two repositories. So if you 
> need MIDAS with MSCB support inside mhttpd, you have to clone MIDAS, MXML and MSCB from bitbucket 
> (or the local clone at TRIUMF) as described in
Entry  26 Nov 2008, Jimmy Ngai, Info, Send email alert in alarm system 
Dear All,

We have a temperature/humidity sensor in MIDAS now and will add a liquid level 
    Reply  26 Nov 2008, Stefan Ritt, Info, Send email alert in alarm system 
> We have a temperature/humidity sensor in MIDAS now and will add a liquid level 
> sensor to MIDAS soon. We want the operators to get alerted ASAP when the 
> laboratory environment or the liquid level reached some critical levels. Can 
Entry  24 Sep 2018, Lars Martin, Suggestion, Self-resetting alarm class 
I was planning to use the alarm system to display an information banner when a
certain valve is open, but I would like it to go away again when the valve is
closed.
    Reply  24 Sep 2018, Lukas Gerritzen, Suggestion, Self-resetting alarm class 
If you run an external script anyway, you can also call "odbedit -c alarm" to
reset all alarms. Or you could try to set the "Triggered" entry of that certain
alarm to 0 (again, with odbedit), that could also work.
    Reply  25 Sep 2018, Stefan Ritt, Suggestion, Self-resetting alarm class 
> If you run an external script anyway, you can also call "odbedit -c alarm" to
> reset all alarms. Or you could try to set the "Triggered" entry of that certain
> alarm to 0 (again, with odbedit), that could also work.
    Reply  25 Sep 2018, Stefan Ritt, Suggestion, Self-resetting alarm class 
> I was planning to use the alarm system to display an information banner when a
> certain valve is open, but I would like it to go away again when the valve is
> closed.
    Reply  26 Dec 2018, Konstantin Olchanski, Suggestion, Self-resetting alarm class 
> > If you run an external script anyway, you can also call "odbedit -c alarm" to
> > reset all alarms. Or you could try to set the "Triggered" entry of that certain
> > alarm to 0 (again, with odbedit), that could also work.