Entry  31 Jan 2014, Stefan Ritt, Info, Separation of MSCB subtree 
Since several projects at PSI need MSCB but not MIDAS, I decided to separate the two repositories. So if you 
need MIDAS with MSCB support inside mhttpd, you have to clone MIDAS, MXML and MSCB from bitbucket 
(or the local clone at TRIUMF) as described in
    Reply  18 Feb 2014, Konstantin Olchanski, Info, Separation of MSCB subtree 
> Since several projects at PSI need MSCB but not MIDAS, I decided to separate the two repositories. So if you 
> need MIDAS with MSCB support inside mhttpd, you have to clone MIDAS, MXML and MSCB from bitbucket 
> (or the local clone at TRIUMF) as described in
Entry  26 Nov 2008, Jimmy Ngai, Info, Send email alert in alarm system 
Dear All,

We have a temperature/humidity sensor in MIDAS now and will add a liquid level 
    Reply  26 Nov 2008, Stefan Ritt, Info, Send email alert in alarm system 
> We have a temperature/humidity sensor in MIDAS now and will add a liquid level 
> sensor to MIDAS soon. We want the operators to get alerted ASAP when the 
> laboratory environment or the liquid level reached some critical levels. Can 
Entry  24 Sep 2018, Lars Martin, Suggestion, Self-resetting alarm class 
I was planning to use the alarm system to display an information banner when a
certain valve is open, but I would like it to go away again when the valve is
closed.
    Reply  24 Sep 2018, Lukas Gerritzen, Suggestion, Self-resetting alarm class 
If you run an external script anyway, you can also call "odbedit -c alarm" to
reset all alarms. Or you could try to set the "Triggered" entry of that certain
alarm to 0 (again, with odbedit), that could also work.
    Reply  25 Sep 2018, Stefan Ritt, Suggestion, Self-resetting alarm class 
> If you run an external script anyway, you can also call "odbedit -c alarm" to
> reset all alarms. Or you could try to set the "Triggered" entry of that certain
> alarm to 0 (again, with odbedit), that could also work.
    Reply  25 Sep 2018, Stefan Ritt, Suggestion, Self-resetting alarm class 
> I was planning to use the alarm system to display an information banner when a
> certain valve is open, but I would like it to go away again when the valve is
> closed.
    Reply  26 Dec 2018, Konstantin Olchanski, Suggestion, Self-resetting alarm class 
> > If you run an external script anyway, you can also call "odbedit -c alarm" to
> > reset all alarms. Or you could try to set the "Triggered" entry of that certain
> > alarm to 0 (again, with odbedit), that could also work.
Entry  08 May 2023, Alexey Kalinin, Forum, Scrript in sequencer 
Hello,

I tried different ways to pass parameters to bash script, but there are seems to 
    Reply  08 May 2023, Stefan Ritt, Forum, Scrript in sequencer 
> I tried different ways to pass parameters to bash script, but there are seems to 
> be empty, what could be the problem?
    Reply  09 May 2023, Alexey Kalinin, Forum, Scrript in sequencer 
Thanks. It works perfect.
Another question is:
Is it possible to run .msl seqscript from bash cmd?
    Reply  10 May 2023, Stefan Ritt, Forum, Scrript in sequencer 
> Thanks. It works perfect.
> Another question is:
> Is it possible to run .msl seqscript from bash cmd?
Entry  04 Aug 2009, Exaos Lee, Forum, Scripts to handle MIDAS sessions utils4midas.zip
Hi, all again

I have some scripts in "bash" and "Python" to handle MIDAS sessions. Please see the attached [url=elog:613/1]utils4midas.zip[/url]. I didn't write instructions
Entry  23 Nov 2009, Exaos Lee, Suggestion, Scripts for "midas-config" genc.zipmidas-config
Supposing you have installed MIDAS to some directory such as "/opt/MIDAS/r4621", you have to write some Makefile as the following while building some applications
based on the version installed:
[quote][code]
Entry  13 Jun 2006, Stefan Ritt, Info, Scheduler changed for slow control equipment 
The schedule in mfe.c is used both for "normal" front-ends and for "slow-control" front-ends. Unfortunately it was only optimized for the first class. This
lead to the fact that the slow control equipment was read out at different speed depending if the run is started or not. Furthermore, the maximum readout
speed was somehow limited. This has been changed in the current version of mfe.c (SVN revision 3146). There are now two ways to control the readout speed
Entry  27 May 2014, Scott Oser, Suggestion, Saving ODB values in a sequencer script 
I have a possibly simple feature request for the MIDAS sequencer.  It would be
helpful to be able to save an ODB key's value to a variable, for later use, and
would be the analogue of the ODBSET command.  I had in mind an application where
    Reply  12 Jun 2014, Stefan Ritt, Suggestion, Saving ODB values in a sequencer script 
> I have a possibly simple feature request for the MIDAS sequencer.  It would be
> helpful to be able to save an ODB key's value to a variable, for later use, and
> would be the analogue of the ODBSET command.  I had in mind an application where
    Reply  12 Jun 2014, Scott Oser, Suggestion, Saving ODB values in a sequencer script 
Thanks, this seems very helpful, and we'll give it a try.

> > I have a possibly simple feature request for the MIDAS sequencer.  It would be
Entry  23 Mar 2020, Ivo Schulthess, Forum, Save data to FTP 
Dear all
I try to save data to an FTP server but don't get any data on the server. Midas does not complain or message any error but also nothing gets saved. Does
somebody have experience with this? I use the following settings for the ODB mlogger channel settings: Type: FTP, Filename: server.com, 21, user, pw, .,