Entry  23 Sep 2015, Peter Kravtsov, Forum, db_paste_node error in offline analyzer 
I have a problem with using analyzer offline.
I'm trying to do it this way:
Entry  22 Nov 2023, Pavel Murat, Forum, run number from an external (*SQL) db? 
Dear MIDAQ developers,

I wonder if there is a non-intrusive way to have an external (wrt MIDAS)*SQL database 
    Reply  01 Dec 2023, Pavel Murat, Forum, run number from an external (*SQL) db? 
> > - multiple subdetectors are taking test data during early commissioning 
> > - a postgres db is a single sorce of run numbers.
> > - test runs taken by different subsystems are assigned different [unique] run numbers and 
Entry  01 Dec 2023, Pavel Murat, Forum, MIDAS state machine : how to get around w/o 'configured' state?  
I have one more question, though I understand that it could be somewhat border-line.

The MIDAS state machine doesn't seem to have a state in between 'initialized' and 
    Reply  02 Dec 2023, Pavel Murat, Forum, run number from an external (*SQL) db? 

> If you go in this direction, there is an alternative to what Ben wrote: Use the sequencer to start a run.
> The sequencer script can obtain a new run number from a central instance (e.g. by calling a shell script 
    Reply  02 Dec 2023, Pavel Murat, Forum, MIDAS state machine : how to get around w/o 'configured' state?  
> - To start a run, we start a special sequencer script. We have different scripts for
> calibration runs, data runs, special runs.
    Reply  03 Dec 2023, Pavel Murat, Forum, run number from an external (*SQL) db? 
> - how does one communicate with an external shell script from MSL ? 

trying to answer my own question, as I didn't find a clear answer in the forum archive :
Entry  09 Dec 2023, Pavel Murat, Forum, how to fix forgotten password ? 
[Dear All, I apologize in advance for spamming.]

1) I tried to login into the forum from the lab computer and realized 
Entry  09 Dec 2023, Pavel Murat, Forum, history plotting: where to convert the ADC readings into temps/voltages? 
to plot time dependencies of the monitored detector parameters, say, voltages or temperatures,
one needs to convert the coresponging ADC readings into floats.
Entry  11 Dec 2023, Pavel Murat, Forum, the logic of handling history variables ? 11x
Dear MIDAS developers,

I'm trying to understand handling of the history (slow control) variables in MIDAS,
    Reply  12 Dec 2023, Pavel Murat, Forum, the logic of handling history variables ? 
Hi Sfefan, thanks a lot for taking time to reproduce the issue! 

Here comes the resolution, and of course, it was something deeply trivial :  
Entry  10 Jan 2024, Pavel Murat, Forum, slow control frontends - how much do they sleep and how often their drivers are called?  
Dear all,

I have implemented a number of slow control frontends which are directed to update the 
    Reply  11 Jan 2024, Pavel Murat, Forum, slow control frontends - how much do they sleep and how often their drivers are called?  
Hi Stefan, thanks a lot !

I just thought that for the EQ_SLOW type equipment calls to sleep() could be hidden in mfe.cxx 
Entry  16 Jan 2024, Pavel Murat, Forum, a scroll option for "add history variables" window? adding_a_variable_to_the_history_plot.png
Dear all,

I have a "slow control" frontend which reads out 100 slow control parameters.
    Reply  17 Jan 2024, Pavel Murat, Forum, a scroll option for "add history variables" window? 
> Have you updated to the current midas version? This issue has been fixed a while ago. 

Hi Stefan, thanks a lot! I pulled from the head, and the scrolling works now. -- regards, Pasha
    Reply  24 Jan 2024, Pavel Murat, Bug Report, Warnings about ODB keys that haven't been touched for 10+ years 
I don't immediately see a reason for saying that if a DB key is older than 10 yrs, it may not be valid.

However, it would be worth learning what was the logic behind choosing 10 yrs as a threshold. 
Entry  28 Jan 2024, Pavel Murat, Forum, number of entries in a given ODB subdirectory ? 
Dear MIDAS experts, 

- I have a detector configuration with a variable number of hardware components - FPGA's receiving data 
    Reply  29 Jan 2024, Pavel Murat, Forum, number of entries in a given ODB subdirectory ? 
Hi Stefan, Konstantin, 

thanks a lot for your responses - they are very teaching and it is good to have them archived in the forum.
    Reply  29 Jan 2024, Pavel Murat, Forum, a scroll option for "add history variables" window? 
> If you have some ideas on how to better present 100500 history variables, please shout out!

let me share some thoughts. In a particular case which lead to the original posting, 
    Reply  03 Feb 2024, Pavel Murat, Forum, number of entries in a given ODB subdirectory ? a.cc
Konstantin is right: KEY.num_values is not the same as the number of subkeys (should it be ?)
For those looking for an example in the future, I attach a working piece of code converted 
from the ChatGPT example, together with its printout.