  Midas DAQ System, Page 64 of 142  Not logged in ELOG logo
Entry  29 Mar 2022, Hunter Lowe, Forum, Triggering without LAM signal - mcstd_libgpmc_camac driver 
Hello,

I have a question for anyone experienced with simple CAMAC systems.
 My understanding is that for a single ADC system you can use a gate to generate a
 LAM signal for triggering on ADC.
 The driver that I have "mcstd_libgpmc_camac" has LAM "not implemented" though,
 so I'm not sure how I should trigger DAQ. The frontend code that I have seems to use a TDC
 as trigger for ADC via "EQ_POLLED" type equipment setting. Should I simply plug in TDC in my
 system and use this as trigger? Is it as simple as TDC generates signal via gate and ADC performs job? 

Sorry if question is super basic, just confused how to trigger without LAM signal.

Thank you :)

Hunter Lowe
UNBC Grad Physics
Entry  02 Sep 2020, Ruslan Podviianiuk, Forum, Transition status message issue.png
Hello,

I got an error after start of run and it would be good to show this error (or 
errors) in UI that I am developing. I see this error in the Transition 
directory (please see the attached file). Is it possible to read the status 
message and error messages from the Transition directory using jsonrpc? If yes, 
could you please explain me how to do this.

Thank you.
Ruslan  
    Reply  02 Sep 2020, Ben Smith, Forum, Transition status message 
The information you want is in the ODB:
* "/System/Transition/status" is the overall integer status code.
* "/System/Transition/error" is the overall error message string.

There is also per-client status information in the ODB:
* "/System/Transition/Clients/<client_name>/status"
* "/System/Transition/Clients/<client_name>/error"
    Reply  02 Sep 2020, Ruslan Podviianiuk, Forum, Transition status message 
> The information you want is in the ODB:
> * "/System/Transition/status" is the overall integer status code.
> * "/System/Transition/error" is the overall error message string.
> 
> There is also per-client status information in the ODB:
> * "/System/Transition/Clients/<client_name>/status"
> * "/System/Transition/Clients/<client_name>/error"


Thank you so much, Ben!
    Reply  08 Sep 2020, Konstantin Olchanski, Forum, Transition status message 
> > The information you want is in the ODB:
> > * "/System/Transition/status" is the overall integer status code.
> > * "/System/Transition/error" is the overall error message string.
> > 
> > There is also per-client status information in the ODB:
> > * "/System/Transition/Clients/<client_name>/status"
> > * "/System/Transition/Clients/<client_name>/error"

You can also use web page .../resources/transition.html as an example of how
to read transition (and other) data from ODB into your own web page. example.html
may also be helpful.

K.O.
    Reply  08 Sep 2020, Ruslan Podviianiuk, Forum, Transition status message 
> > > The information you want is in the ODB:
> > > * "/System/Transition/status" is the overall integer status code.
> > > * "/System/Transition/error" is the overall error message string.
> > > 
> > > There is also per-client status information in the ODB:
> > > * "/System/Transition/Clients/<client_name>/status"
> > > * "/System/Transition/Clients/<client_name>/error"
> 
> You can also use web page .../resources/transition.html as an example of how
> to read transition (and other) data from ODB into your own web page. example.html
> may also be helpful.
> 
> K.O.

Thank you Konstantin!

Ruslan
Entry  20 Nov 2013, Konstantin Olchanski, Bug Report, Too many bm_flush_cache() in mfe.c 
I was looking at something in the mserver and noticed that for remote frontends, for every periodic event, 
there are about 3 RPC calls to bm_flush_cache().

Sure enough, in mfe.c::send_event(), for every event sent, there are 2 calls to bm_flush_cache() (once for 
the buffer we used, second for all buffers). Then, for a good measure, the mfe idle loop calls 
bm_flush_cache() for all buffers about once per second (even if no events were generated).

So what is going on here? To allow good performance when processing many small events,
the MIDAS event buffer code (bm_send_event()) buffers small events internally, and only after this internal
buffer is full, the accumulated events are flushed into the shared memory event buffer,
where they become visible to the mlogger, mdump and other consumers.

Because of this internal buffering, infrequent small size periodic events can become
stuck for quite a long time, confusing the user: "my frontend is sending events, how come I do not
see them in mdump?"

To avoid this, mfe.c manually flushes these internal event buffers by calling bm_flush_buffer().

And I think that works just fine for frontends directly connected to the shared memory, one call to 
bm_flush_buffer() should be sufficient.

But for remote fronends connected through the mserver, it turns out there is a race condition between 
sending the event data on one tcp connection and sending the bm_flush_cache() rpc request on another 
tcp connection.

I see that the mserver always reads the rpc connection before the event connection, so bm_flush_cache() 
is done *before* the event is written into the buffer by bm_send_event(). So the newly
send event is stuck in the buffer until bm_flush_cache() for the *next* event shows up:

mfe.c: send_event1 -> flush -> ... wait until next event ... -> send_event2 -> flush
mserver: flush -> receive_event1 -> ... wait ... -> flush -> receive_event2 -> ... wait ...
mdump -> ... nothing ... -> ... nothing ... -> event1 -> ... nothing ...

Enter the 2nd call to bm_flush_cache in mfe.c (flush all buffers) - now because mserver seems to be 
alternating between reading the rpc connection and the event connection, the race condition looks like 
this:

mfe.c: send_event -> flush -> flush
mserver: flush -> receive_event -> flush
mdump: ... -> event -> ...

So in this configuration, everything works correctly, the data is not stuck anywhere - but by accident, and 
at the price of an extra rpc call.

But what about the periodic 1/second bm_flush_cache() on all buffers? I think it does not quite work
either because the race condition is still there: we send an event, and the first flush may race it and only 
the 2nd flush gets the job done, so the delay between sending the event and seeing it in mdump would be 
around 1-2 seconds. (no more than 2 seconds, I think). Since users expect their events to show up "right
away", a 2 second delay is probably not very good.

Because periodic events are usually not high rate, the current situation (4 network transactions to send 1 
event - 1x send event, 3x flush buffer) is probably acceptable. But this definitely sets a limit on the 
maximum rate to 3x (2x?) the mserver rpc latency - without the rpc calls to bm_flush_buffer() there
would be no limit - the events themselves are sent through a pipelined tcp connection without 
handshaking.

One solution to this would be to implement periodic bm_flush_buffer() in the mserver, making all calls to 
bm_flush_buffer() in mfe.c unnecessary (unless it's a direct connection to shared memory).

Another solution could be to send events with a special flag telling the mserver to "flush the buffer right 
away".

P.S. Look ma!!! A race condition with no threads!!!

K.O.
    Reply  21 Nov 2013, Stefan Ritt, Bug Report, Too many bm_flush_cache() in mfe.c 
> And I think that works just fine for frontends directly connected to the shared memory, one call to 
> bm_flush_buffer() should be sufficient.

That's correct. What you want is once per second or so for polled events, and once per periodic event (which anyhow will typically come only every 10 seconds or so). If there are 3 calls 
per event, this is certainly too much.


> But for remote fronends connected through the mserver, it turns out there is a race condition between 
> sending the event data on one tcp connection and sending the bm_flush_cache() rpc request on another 
> tcp connection.
> 
> ...
> 
> One solution to this would be to implement periodic bm_flush_buffer() in the mserver, making all calls to 
> bm_flush_buffer() in mfe.c unnecessary (unless it's a direct connection to shared memory).
> 
> Another solution could be to send events with a special flag telling the mserver to "flush the buffer right 
> away".

That's a very good and useful observation. I never really thought about that. 

Looking at your proposed solutions, I prefer the second one. mserver is just an interface for RPC calls, it should not do anything "by itself". This was a strategic decision at the beginning. 
So sending a flag to punch through the cache on mserver seems to me has less side effects. Will just break binary compatibility :-)

/Stefan
Entry  01 Sep 2009, Jimmy Ngai, Forum, Timeout during run transition 
Dear All,

I'm using SL5 and MIDAS rev 4528. Occasionally, when I stop a run in odbedit, 
a timeout would occur: 
[midas.c:9496:rpc_client_call,ERROR] rpc timeout after 121 sec, routine 
= "rc_transition", host = "computerB", connection closed
Error: Unknown error 504 from client 'Frontend' on host computerB

This error seems to be random without any reason or pattern. After this error 
occurs, I cannot start or stop any run. Sometime restarting MIDAS can bring 
the system working again, but sometime not.

Another transition timeout occurs after I change any ODB value using the web 
interface:
[midas.c:8291:rpc_client_connect,ERROR] timeout on receive remote computer 
info: 
[midas.c:3642:cm_transition,ERROR] cannot connect to client "Frontend" on host 
computerB, port 36255, status 503
Error: Cannot connect to client 'Frontend'

This error is reproducible: start run -> change ODB value within webpage -> 
stop run -> timeout!

Any idea?

Thanks,
Jimmy
    Reply  03 Sep 2009, Stefan Ritt, Forum, Timeout during run transition 
> Dear All,
> 
> I'm using SL5 and MIDAS rev 4528. Occasionally, when I stop a run in odbedit, 
> a timeout would occur: 
> [midas.c:9496:rpc_client_call,ERROR] rpc timeout after 121 sec, routine 
> = "rc_transition", host = "computerB", connection closed
> Error: Unknown error 504 from client 'Frontend' on host computerB
> 
> This error seems to be random without any reason or pattern. After this error 
> occurs, I cannot start or stop any run. Sometime restarting MIDAS can bring 
> the system working again, but sometime not.
> 
> Another transition timeout occurs after I change any ODB value using the web 
> interface:
> [midas.c:8291:rpc_client_connect,ERROR] timeout on receive remote computer 
> info: 
> [midas.c:3642:cm_transition,ERROR] cannot connect to client "Frontend" on host 
> computerB, port 36255, status 503
> Error: Cannot connect to client 'Frontend'
> 
> This error is reproducible: start run -> change ODB value within webpage -> 
> stop run -> timeout!

A few hints for debugging:

- do the run stop via odbedit and the "-v" flag, like

[local:Online:R]/> stop -v

then you see which computer is contacted when.

- Then put some debugging code into your front-end end_of_run() routine at the 
beginning and the end of that routine, so you see when it's executed and how long 
this takes. If you do lots of things in your EOR routine, this could maybe cause a 
timeout.

- Then make sure that cm_yield() in mfe.c is called periodically by putting some 
debugging code there. This function checks for any network message, such as the 
stop command from odbedit. If you trigger event readout has an endless loop for 
example, cm_yield() will never be called and any transition will timeout.

- Make sure that not 100% CPU is used on your frontend. Some OSes have problems 
handling incoming network connections if the CPU is completely used of if 
input/output operations are too heavy.

- Stefan
Entry  09 Apr 2021, Lars Martin, Suggestion, Time zone selection for web page 
The new history as well as the clock in the web page header show the local time 
of the user's computer running the browser.
Would it be possible to make it either always use the time zone of the Midas 
server, or make it selectable from the config page?
It's not ideal trying to relate error messages from the midas.log to history 
plots if the time stamps don't match.
    Reply  14 Apr 2021, Stefan Ritt, Suggestion, Time zone selection for web page Screenshot_2021-04-14_at_16.54.12_.png
> The new history as well as the clock in the web page header show the local time 
> of the user's computer running the browser.
> Would it be possible to make it either always use the time zone of the Midas 
> server, or make it selectable from the config page?
> It's not ideal trying to relate error messages from the midas.log to history 
> plots if the time stamps don't match.

I implemented a new row in the config page to select the time zone. 

"Local": Time zone where the browser runs
"Server": Time zone where the midas server runs (you have to update mhttpd for that)
"UTC+X": Any other time zone

The setting affects both the status header and the history display.

I spent quite some time with "named" time zones like "PST" "EST" "CEST", but the 
support for that is not that great in JavaScript, so I decided to go with simple 
UTC+X. Hope that's ok.

Please give it a try and let me know if it's working for you.

Best,
Stefan
    Reply  29 Apr 2021, Pierre-Andre Amaudruz, Suggestion, Time zone selection for web page 
> > The new history as well as the clock in the web page header show the local time 
> > of the user's computer running the browser.
> > Would it be possible to make it either always use the time zone of the Midas 
> > server, or make it selectable from the config page?
> > It's not ideal trying to relate error messages from the midas.log to history 
> > plots if the time stamps don't match.
> 
> I implemented a new row in the config page to select the time zone. 
> 
> "Local": Time zone where the browser runs
> "Server": Time zone where the midas server runs (you have to update mhttpd for that)
> "UTC+X": Any other time zone
> 
> The setting affects both the status header and the history display.
> 
> I spent quite some time with "named" time zones like "PST" "EST" "CEST", but the 
> support for that is not that great in JavaScript, so I decided to go with simple 
> UTC+X. Hope that's ok.
> 
> Please give it a try and let me know if it's working for you.
> 
> Best,
> Stefan

Hi Stefan,

This is great, the UTC+x is perfect, thank you.
PAA
Entry  23 Mar 2021, Lars Martin, Bug Report, Time shift in history CSV export Cooling-MoxaCalib-20212118-190450-20212119-102151.pngScreenshot_from_2021-03-23_12-29-21.png
Version: release/midas-2020-12

I'm exporting the history data shown in elog:2132/1 to CSV, but when I look at the 
CSV data, the step no longer occurs at the same time in both data sets (elog:2132/2)
    Reply  23 Mar 2021, Lars Martin, Bug Report, Time shift in history CSV export 
History is from two separate equipments/frontends, but both have "Log history" set to 1.
    Reply  23 Mar 2021, Lars Martin, Bug Report, Time shift in history CSV export 
Tried with export of two different time ranges, and the shift appears to remain the same, 
about 4040 rows.
    Reply  24 Mar 2021, Stefan Ritt, Bug Report, Time shift in history CSV export 
I confirm there is a problem. If variables are from the same equipment, they have the same 
time stamps, like

t1 v1(t1) v2(t1)
t2 v1(t2) v2(t2)
t3 v1(t3) v2(t3)

when they are from different equipments, they have however different time stamps

t1 v1(t1)
t2    v2(t2)
t3 v1(t3)
t4    v2(t4)

The bug in the current code is that all variables use the time stamps of the first variable, 
which is wrong in the case of different equipments, like

t1 v1(t1) v2(*t2*)
t3 v1(t3) v2(*t4*)

So I can change the code, but I'm not sure what would be the bast way. The easiest would be to 
export one array per variable, like

t1 v1(t1)
t2 v1(t2)
...
t3 v2(t3)
t4 v2(t4)
...

Putting that into a single array would leave gaps, like

t1 v1(t1) [gap]
t2 [gap]  v2(t2)
t3 v1(t3) [gap]
t4 [ga]]  v2(t4)

plus this is programmatically more complicated, since I have to merge two arrays. So which 
export format would you prefer?

Stefan
    Reply  24 Mar 2021, Lars Martin, Bug Report, Time shift in history CSV export 
I think from my perspective the separate files are fine. I personally don't really like the format 
with the gaps, so don't see an advantage in putting in the extra work.
I'm surprised the shift is this big, though, it was more than a whole hour in my case, is it the 
time difference between when the frontends were started?
    Reply  14 Apr 2021, Stefan Ritt, Bug Report, Time shift in history CSV export 
I finally found some time to fix this issue in the latest commit. Please update and check if it's 
working for you.

Stefan
Entry  15 Jun 2009, Jimmy Ngai, Forum, Time limit of each run 
Dear All,

Can one set a time limit for each run? I can only find event limit in ODB. 
Thanks.

Jimmy